Diagnostic accuracy of transabdominal ultrasound in detecting prenatal cleft lip and palate: a systematic review
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Objectives: To systematically review the diagnostic accuracy of second‐trimester transabdominal ultrasound in detecting orofacial clefts in low‐ and high‐risk populations and to compare two‐dimensional (2D) with three‐dimensional (3D) ultrasound techniques. Methods: MEDLINE and EMBASE were searched for articles published in English, Dutch, French or German using the keywords ‘cleft’ and ‘ultrasound’ or ‘screening’ or ‘sonogram’ and ‘prenatal’ or ‘antenatal’ or ‘fetus’ to identify cohort studies and randomized trials in order to assess the detection rate by prenatal ultrasound of cleft lip and palate in high‐risk and low‐risk pregnant women. Results: Of 451 citations identified, 27 met the criteria for the systematic review, 21 involving unselected low‐risk populations and six involving high‐risk populations. In the selected studies there was diversity in the gestational age at which the ultrasound examination was performed and there was considerable variety in the diagnostic accuracy of 2D ultrasound in the low‐risk women, with prenatal detection rates ranging from 9% to 100% for cleft lip with or without cleft palate, 0% to 22% for cleft palate only and 0% to 73% for all types of cleft. 3D ultrasound in high‐risk women resulted in a detection rate of 100% for cleft lip, 86% to 90% for cleft lip with palate and 0% to 89% for cleft palate only. Conclusions: 2D ultrasound screening for cleft lip and palate in a low‐risk population has a relatively low detection rate but is associated with few false‐positive results. 3D ultrasound can achieve a reliable diagnosis, but not of cleft palate only. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
The performance of routine ultrasonographic screening of pregnancies in the Eurofetus Study
Grandjean, H., Larroque, D., & Levi, S. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70577-6 · Cited by 542 · cited 1×
“4 57/316 (18); 56/144 (39) 1/72 (1) 18/316 (6)† Stefos25 (1999) 7236 18–22 NS (NS) 3/6 CL only (50) NS (NS) Clementi16 (2000) 709 030 25.”
Crane, J. P., LeFevre, M. L., Winborn, R. C., Evans, J. K., Ewigman, B. G., Bain, R. P., Frigoletto, F. D., & McNellis, D. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70040-0 · Cited by 390
Chitty, L. S., Hunt, G. H., Moore, J., & Lobb, M. O. (1991) · BMJ · doi:10.1136/bmj.303.6811.1165 · Cited by 292
6-year experience of prenatal diagnosis in an unselected population in Oxford, UK
Boyd, P., Chamberlain, P., & Hicks, N. (1998) · The Lancet · doi:10.1016/s0140-6736(98)03202-4 · Cited by 160
Clementi, M., Tenconi, R., Bianchi, F., Stoll, C. G., & EUROSCAN study group (2000) · Prenatal Diagnosis · doi:10.1002/1097-0223(200011)20:11<870::aid-pd940>3.0.co;2-j · Cited by 154
Rotten, D., & Levaillant, J. M. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1718 · Cited by 147 · cited 1×
“Retrospective studies Chen29 (2001) 21 20–34 NS (NS) 2D/Uni: 5/16 (31) NS (NS) NS (NS) (mean, 25.”
AIUM Practice Guideline for the Performance of an Antepartum Obstetric Ultrasound Examination
(2003) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2003.22.10.1116 · Cited by 141
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Ca, G., Glasziou, P., Irwig, L., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · PubMed · Cited by 133
Cash, C. J. C., Set, P. A. K., & Coleman, N. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.0960-7692.2001.00508.x · Cited by 118 · cited 3×
“9) 41/56 (73) NS (NS) NS (NS) Wayne27 (2002) 17 551 20–22 NS (NS) 9/12 (75) NS (NS) Tonni26 (2005) 1856 21 ± 2 NS (NS) 2/2 (100) NS (NS) Nikkilä21 (2006) 141 240 < 23 (49%) NS (NS) 21/240 CL only (9) NS (NS) Russell24 (2008) 108 220 28.”
Cited by
Sideri, S., Papageorgiou, S. N., & Eliades, T. (2018) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.01.003 · Cited by 388
First and second trimester screening for fetal structural anomalies
Edwards, L., & Hui, L. (2018) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2017.11.005 · Cited by 179
Maxillary gap at 11–13 weeks’ gestation: Marker of cleft lip and palate
Chaoui, R., Orosz, G., Heling, K. S., Sarut‐Lopez, A., & Nicolaides, K. H. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15675 · Cited by 105
Metadata
- Authors
- Maarse, W., Bergé, S. J., Pistorius, L., van Barneveld, T., Kon, M., Breugem, C., & Mink van der Molen, A. B.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2010-03-16
- Volume
- 35
- Issue
- 4
- Pages
- 495-502
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2051471375
- Cited by
- 194
- References
- 20
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.