CoChat

Quantitative analysis of antral follicle number and size: a comparison of two‐dimensional and automated three‐dimensional ultrasound techniques

Deb, S., Campbell, B. K., Clewes, J. S., Raine‐Fenning, N. J. · 2010 · Ultrasound in Obstetrics & Gynecology
Cited by 87

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objectives: To compare two‐dimensional (2D) ultrasound imaging with automated three‐dimensional (3D) ultrasound imaging for the measurement of antral follicle number and size. Methods: Twenty‐four subjects aged < 40 years underwent transvaginal ultrasound examination (Voluson E8) in the early follicular phase of the menstrual cycle. A 2D ultrasound scan of both ovaries was performed; each antral follicle was identified and then measured by taking the mean of two diameters. A 3D ultrasound dataset of both ovaries was then acquired and analyzed using Sonography‐based Automated Volume Count (SonoAVC™). The time taken to measure the size of all antral follicles in both ovaries was recorded in seconds for each technique. Antral follicle size was recorded to the nearest millimeter and counts for each 1‐mm group were obtained. Antral follicle counts were also grouped according to five predefined size categories: 2.0–5.0 mm, 2.0–6.0 mm, 2.0–8.0 mm, 2.0–9.0 mm and 2.0–10.0 mm. Limits of agreement (LOA) and a paired t‐test or Wilcoxon signed ranks test were used to analyze the data depending on their distribution. Results: When antral follicle numbers were compared for each 1‐mm follicle size group, 2D ultrasound imaging recorded more follicles measuring 3.0–3.99 mm (mean ± SD, 4.11 ± 3.70 vs. 2.63 ± 2.31; P = 0.019) and 4.0–4.99 mm (mean ± SD, 4.63 ± 4.86 vs. 2.68 ± 2.89; P = 0.013) than did SonoAVC. LOA were widest with follicles measuring 3.0–3.99 mm (LOA, 6.38 and −3.43) and 4.0–4.99 mm (LOA, 7.99 and −4.09). The antral follicle count in each of the five predefined size categories was significantly lower with SonoAVC than with 2D ultrasound imaging (P < 0.05). SonoAVC took significantly less time to measure the size and record the number of antral follicles than did 2D ultrasound imaging (mean ± SD, 132.05 ± 56.23 s vs. 324.47 ± 162.22 s; P < 0.001). Conclusions: Fewer antral follicles are evident overall when SonoAVC is used to analyze 3D ultrasound data. The clinical significance of this remains to be determined but the automated technique is significantly quicker than is making measurements using 2D ultrasound imaging. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.7505

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 87

Metadata

Authors
Deb, S., Campbell, B. K., Clewes, J. S., & Raine‐Fenning, N. J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2010-03
Volume
35
Issue
3
Pages
354-360
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2019588336
Cited by
87
References
2
FWCI
3.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative analysis of antral follicle number and size: a comparison of two‐dimensional and automated three‐dimensional ultrasound techniques. https://app.cochat.ai/papers/10.1002/uog.7505
The paper
Deb, S., Campbell, B. K., Clewes, J. S., & Raine‐Fenning, N. J. (2010). Quantitative analysis of antral follicle number and size: a comparison of two‐dimensional and automated three‐dimensional ultrasound techniques. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.7505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.