The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Measurement of fetal head descent using the ‘angle of progression’ on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise
Open accessAbstract
Objectives: To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. Methods: One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland–Altman analysis was used to assess interobserver agreement. Results: In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63–0.81). ICCs were 0.82 (95% CI, 0.70–0.89), 0.81 (95% CI, 0.71–0.88) and 0.61 (95% CI, 0.43–074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland–Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, −1.09°; 95% limits of agreement, −8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70–0.93). Conclusions: Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
ISUOG Practice Guidelines: intrapartum ultrasound
Ghi, T., Eggebø, T., Lees, C., Kalache, K., Rozenberg, P., Youssef, A., Salomon, L. J., & Tutschek, B. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19072 · Cited by 348
Self-citationBai, J., Sun, Z., Yu, S., Lu, Y., Long, S., Wang, H., Qiu, R., Ou, Z., Zhou, M., Zhi, D., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.940150 · Cited by 36
Multitask Deep Neural Network for the Fully Automatic Measurement of the Angle of Progression
Lu, Y., Zhi, D., Zhou, M., Lai, F., Chen, G., Ou, Z., Zeng, R., Long, S., Qiu, R., Zhou, M., et al. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/5192338 · Cited by 30
Metadata
- Authors
- Dückelmann, A. M., Bamberg, C., Michaelis, S. A. M., Lange, J., Nonnenmacher, A., Dudenhausen, J. W., & Kalache, K. D.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2010-01-25
- Volume
- 35
- Issue
- 2
- Pages
- 216-222
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2038388328
- Cited by
- 167
- References
- 2
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of fetal head descent using the ‘angle of progression’ on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise. https://app.cochat.ai/papers/10.1002/uog.7521
- The paper
- Dückelmann, A. M., Bamberg, C., Michaelis, S. A. M., Lange, J., Nonnenmacher, A., Dudenhausen, J. W., & Kalache, K. D. (2010). Measurement of fetal head descent using the ‘angle of progression’ on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.7521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.