CoChat

Middle versus anterior cerebral artery Doppler for the prediction of perinatal outcome and neonatal neurobehavior in term small‐for‐gestational‐age fetuses with normal umbilical artery Doppler

Oros, D., Figueras, F., Cruz‐Martinez, R., Padilla, N., Meler, E., Hernandez‐Andrade, E., Gratacos, E. · 2010 · Ultrasound in Obstetrics & Gynecology
Cited by 93

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective: To evaluate whether anterior cerebral artery (ACA) Doppler ultrasonography is superior to middle cerebral artery (MCA) Doppler in the prediction of perinatal outcome and neonatal neurobehavior in term small‐for‐gestational‐age (SGA) fetuses with normal umbilical artery (UA) Doppler. Methods: MCA and ACA Doppler ultrasonography was performed in a cohort of SGA term fetuses with normal UA Doppler. Perinatal outcome and neonatal neurobehavioral performance were compared with a group of term appropriate‐for‐gestational age (AGA) infants. Neurobehavior was evaluated at 40 ( ± 1) weeks of corrected age with the Neonatal Behavioral Assessment Scale. Differences between the study groups were adjusted for potential confounding variables by multiple linear or logistic regression analyis. Results: A total of 199 newborns (98 SGA and 101 AGA) were included. Among the SGA fetuses, 28.6 and 17% had MCA and ACA redistribution, respectively. Cases with either type of redistribution had an increased risk for adverse outcome, with no differences in predictive performance between the two parameters. SGA fetuses with MCA redistribution compared with controls had an increased risk for abnormal neurobehavioral performance in motor (36 vs. 20%; adjusted P = 0.02) and state organization (25 vs. 17.5%; adjusted P = 0.03) areas. SGA fetuses with ACA redistribution had only an increased risk for abnormal neurobehavioral performance area in state organization compared with controls (30 vs. 17.5%; adjusted P = 0.021). Conclusion: In term SGA newborns with no signs of brain‐sparing, ACA Doppler investigation does not provide any benefit over MCA in terms of the prediction of adverse perinatal outcome. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.7588

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 93

Metadata

Authors
Oros, D., Figueras, F., Cruz‐Martinez, R., Padilla, N., Meler, E., Hernandez‐Andrade, E., & Gratacos, E.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2010-03-24
Volume
35
Issue
4
Pages
456-461
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2059626849
Cited by
93
References
5
FWCI
8.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.