Factors influencing the prenatal detection of structural congenital heart diseases
The DOI matches its Crossref record.
Abstract
Objective: To assess the factors influencing the prenatal detection rate of structural congenital heart diseases (CHDs). Methods: A retrospective study was conducted at a major obstetric hospital in Australia between 1 January 1996 and 30 June 1999. The medical records of all fetuses and infants born with CHD, except those with isolated patent ductus arteriosus or secundum atrial septal defect, were reviewed. Only pregnancies that had prenatal ultrasound scan assessments for morphological surveys were included. The following factors that may influence the detection rate were assessed: complexity of the lesions; experience of the sonographers (performance in tertiary versus non‐tertiary institutions); presence of other structural or chromosomal anomalies; and maternal body mass index (BMI). Results: The incidence of structural CHD in this series, excluding cases referred from other hospitals, was 7.0 per 1000 (179/25 529). Of the 179 pregnancies with CHD, 151 had prenatal ultrasound scans and were included in the study. The overall detection rate for CHDs in this series was 40.4%. The detection rate for isolated septal defects was poor (13.7%). The detection rates were significantly higher for complex lesions (54%), for lesions with concomitant septal defects (66.7%), and for lesions with abnormal four‐chamber views (62.9%). The detection rate was also higher if the scan was performed in the tertiary institution, and if there were other chromosomal or structural anomalies. Maternal BMI did not affect the detection rate in the current series. Stepwise logistic regression analysis showed that three independent variables affecting the detection rate were complexity of the cardiac lesion, experience of the operator, and the detection of chromosomal anomalies. Conclusion: A high detection rate for major CHDs can be achieved in a screening setting but there is still room for improvement in scanning skills in the four‐chamber view and great‐artery analysis in both tertiary and local centers. Copyright © 2002 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2710 · Cited by 308
Prenatal detection of congenital heart disease
Friedberg, M. K., Silverman, N. H., Moon-Grady, A. J., Tong, E., Nourse, J., Sorenson, B., Lee, J., & Hornberger, L. K. (2009) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.01.050 · Cited by 299
Bakker, M. K., Bergman, J. E. H., Krikov, S., Amar, E., Cocchi, G., Cragan, J., de Walle, H. E. K., Gatt, M., Groisman, B., Liu, S., et al. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-028139 · Cited by 255
Tegnander, E., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2804 · Cited by 241
Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation
Gonçalves, L. F., Lee, W., Chaiworapongsa, T., Espinoza, J., Schoen, M. L., Falkensammer, P., Treadwell, M., & Romero, R. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(03)00913-x · Cited by 233
Fanaroff, A. A. (2008) · Yearbook of Neonatal and Perinatal Medicine · doi:10.1016/s8756-5005(08)79214-x · Cited by 207
Barriers to prenatal detection of congenital heart disease: a population‐based study
Pinto, N. M., Keenan, H. T., Minich, L. L., Puchalski, M. D., Heywood, M., & Botto, L. D. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10116 · Cited by 164
“US location Clinic 164 (22) 1 Hospital 65 (31) 1.”
Why are congenital heart defects being missed?
van Nisselrooij, A. E. L., Teunissen, A. K. K., Clur, S. A., Rozendaal, L., Pajkrt, E., Linskens, I. H., Rammeloo, L., van Lith, J. M. M., Blom, N. A., & Haak, M. C. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20358 · Cited by 158
Viñals, F., Mandujano, L., Vargas, G., & Giuliano, A. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1796 · Cited by 147
Artificial intelligence in perinatal diagnosis and management of congenital heart disease
Reddy, C. D., Van den Eynde, J., & Kutty, S. (2022) · Seminars in Perinatology · doi:10.1016/j.semperi.2022.151588 · Cited by 32
Karim, J. N., Campbell, H., Pandya, P., Wilson, E. C. F., Alfirevic, Z., Chudleigh, T., Duff, E., Fisher, J., Goodman, H., Hinton, L., et al. (2025) · Health Technology Assessment · doi:10.3310/nltp7102 · Cited by 5
Metadata
- Authors
- Wong, S. F., Chan, F. Y., Cincotta, R. B., Lee‐Tannock, A., & Ward, C.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2002-12-12
- Volume
- 21
- Issue
- 1
- Pages
- 19-25
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2060702271
- Cited by
- 96
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.