The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Ultrasound imaging of the pelvic floor. Part I: two‐dimensional aspects
Open accessAbstract
Ultrasound imaging is rapidly replacing radiological methods in the investigation of pelvic floor disorders. Transrectal, transvaginal/introital and transperineal/translabial methods are being employed, with the latter probably the most widespread due to ease of use and availability of equipment. Position and mobility of the bladder neck, bladder wall thickness, pelvic floor muscle activity and uterovaginal prolapse can be quantified, and color Doppler may be used to document stress urinary incontinence. Ultrasound imaging has simplified audit activities and enhanced our understanding of the effects of incontinence and prolapse surgery, such as the new synthetic suburethral slings. In recent years, imaging methods have contributed significantly to our understanding of the traumatic effects of childbirth on the pelvic floor. Finally, the assessment of pelvic floor biomechanics may have implications for clinical obstetrics and ultimately for the prevention of delivery‐related pelvic floor trauma. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction
Bump, R. C., Mattiasson, A., Bø, K., Brubaker, L. P., DeLancey, J. O. L., Klarskov, P., Shull, B. L., & Smith, A. R. B. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70243-0 · Cited by 4,275
Perineal ultrasound for evaluating the bladder neck in urinary stress incontinence
SCHAER, G., KOECHLI, O., SCHUESSLER, B., & HALLER, U. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00369-o · Cited by 274
Ultrasound in the quantification of female pelvic organ prolapse
Dietz, H. P., Haylen, B. T., & Broome, J. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00494.x · Cited by 245
Self-citationTextbook of Female Urology and Urogynaecology
Cardozo, L. (2004) · CRC Press eBooks · doi:10.3109/9780203213957 · Cited by 234
Levator ani function before and after childbirth
Peschers, U. M., Schaer, G. N., DeLancey, J. O. L., & Schuessler, B. (1997) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb12057.x · Cited by 202
Changes in vesical neck mobility following vaginal delivery
PESCHERS, U., SCHAER, G., ANTHUBER, C., OLDELANCEY, J., & SCHUESSLER, B. (1996) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(96)00338-9 · Cited by 196
Urinary stress incontinence: Differential diagnosis, pathophysiology, and management
Green, T. H. (1975) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(75)90186-6 · Cited by 183
Observations on Stress Incontinence of Urine
Jeffcoate, T. N. A., & Roberts, H. (1952) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)38792-0 · Cited by 179
The Use of Perineal Ultrasound to Quantify Levator Activity and Teach Pelvic Floor Muscle Exercises
Dietz, H. P., Wilson, P. D., & Clarke, B. (2001) · International Urogynecology Journal · doi:10.1007/s001920170059 · Cited by 177
Self-citationReilly, E. T. C., Freeman, R. M., Waterfield, M. R., Waterfield, A. E., Steggles, P., & Pedlar, F. (2014) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13213 · Cited by 173
Research works printed but not linked: 53
- Schubert E, 1929, Topographie des Uterus und der Harnblase im Roentgenprofilbild, Zentralbl Gynakol, 53, 1182
- Mikulicz‐Radecki J, 1931, Roentgenologische Studien zur Aetiologie der urethralen Inkontinenz, Zentralbl Gynakol, 55, 795
- 10.1055/s-2008-1035864 · doi:10.1055/s-2008-1035864
- 10.1055/s-2008-1036805 · doi:10.1055/s-2008-1036805
- 10.1055/s-2007-1011937 · doi:10.1055/s-2007-1011937
- 10.1111/j.1464-410X.1988.tb04387.x · doi:10.1111/j.1464-410x.1988.tb04387.x
- 10.1002/uog.189 · doi:10.1002/uog.189
- 10.1007/BF00931401 · doi:10.1007/bf00931401
- 10.1055/s-2008-1036075 · doi:10.1055/s-2008-1036075
- 10.1007/BF00460314 · doi:10.1007/bf00460314
- Dietz HP, 1996, Anatomical assessment of the bladder outlet and proximal urethra using ultrasound and videocystourethrography, Neurourol Urodyn, 15, 363
- 10.1097/00001703-199710000-00008 · doi:10.1097/00001703-199710000-00008
- 10.1055/s-2008-1032891 · doi:10.1055/s-2008-1032891
- 10.1016/S0029-7844(97)00681-9 · doi:10.1016/s0029-7844(97)00681-9
- 10.1007/PL00004011 · doi:10.1007/pl00004011
- 10.1007/PL00004030 · doi:10.1007/pl00004030
- 10.1007/s001920170031 · doi:10.1007/s001920170031
- Martan A, 1994, Ultrasound of the bladder neck–urethra transition before and after pelvic floor training with Kolpexin [in German], Zentralbl Gynakol, 116, 416
- 10.1007/s001920200063 · doi:10.1007/s001920200063
- DietzHP SteensmaAB EldridgeA GraceM ClarkeB.Test‐retest and Interrater Reliability of the Ultrasound Assessment of Bladder Neck Mobility. Abstract presented at the International Urogynecological Association (IUGA) Conference Buenos Aires Argentina 2003.
- 10.1002/nau.1930130603 · doi:10.1002/nau.1930130603
- Reed H, 2002, Bladder neck mobility in continent nulliparous women: normal references, Int Urogynecol J, 13, S4
- 10.1007/s001920050005 · doi:10.1007/s001920050005
- 10.1111/j.1471-0528.1998.tb10009.x · doi:10.1111/j.1471-0528.1998.tb10009.x
- 10.1097/00006250-199903000-00020 · doi:10.1097/00006250-199903000-00020
- 10.1007/s001920170092 · doi:10.1007/s001920170092
- 10.1016/S0029-7844(98)00248-8 · doi:10.1016/s0029-7844(98)00248-8
- Digesu GA, 2000, Pregnancy, childbirth and urinary incontinence: Caesarean for all?, Neurourol Urodyn, 19, 508
- 10.1046/j.0004-8666.2003.00017.x · DOI
- Balmforth J, 2003, Ask not what childbirth can do to your pelvic floor but what your pelvic floor can do in childbirth, Neurourol Urodyn, 22, 540
- Kim SJ, 1999, The significance of an open bladder neck in the evaluation of female stress urinary incontinence, Int Urogynecol J, 10, S59
- 10.1016/0029-7844(95)00301-7 · doi:10.1016/0029-7844(95)00301-7
- Masata J, 1999, Ultrasound imaging of urethral funneling, Int Urogynecol J, 10, S62
- 10.1046/j.1469-0705.1999.14020144.x · doi:10.1046/j.1469-0705.1999.14020144.x
- 10.1007/s001920170030 · doi:10.1007/s001920170030
- Masata J, 2001, Detection of Valsalva leak point pressure with color Doppler—new method for routine use, Neurourol Urodyn, 20, 494
- 10.1111/j.1471-0528.2002.01021.x · doi:10.1111/j.1471-0528.2002.01021.x
- Soligo M, 2002, Overactive bladder definition and ultrasound measurement of bladder wall thickness: the right way without urodynamics, Neurourol Urodyn, 21, 284
- Dietz HP, 2003, Levator function before and after childbirth, Aust N Z J Obstet Gynaecol
- 10.1097/00006250-200102000-00017 · doi:10.1097/00006250-200102000-00017 · Paper page
- 10.3109/00016349609033318 · doi:10.3109/00016349609033318
- 10.2214/ajr.170.5.9574599 · doi:10.2214/ajr.170.5.9574599
- Bombieri L, 1999, Do bladder neck position and amount of elevation influence the surgical outcome of colposuspension?, Neurourol Urodyn, 18, 316
- Dietz HP, 2000, How does the TVT achieve continence?, Neurourol Urodyn, 19, 393
- Lo TS, 2000, Ultrasonographic and urodynamic evaluation after tension‐free vaginal tape procedure (TVT), Int Urogynecol J, 11, S31
- Martan A, 2002, The ultrasound imaging of the tape after TVT procedure, Neurourol Urodyn, 21, 322
- Masata J, 2002, Ultrasound study of the effect of TVT operation on the mobility of the whole urethra, Neurourol Urodyn, 21, 286
- Dietz HP, 2003, How important is TVT location?, Acta Obstet Gynecol Scand
- 10.1067/mob.2003.268 · doi:10.1067/mob.2003.268
- FritelX ZabakK PigneA BeniflaJ.Predictive Value of the Urethra Mobility Before Sub‐urethra Tape Procedure for Stress Urinary Incontinence in Women. Abstract presented at the Annual Meeting of the International Continence Society Heidelberg Germany 2002;190–191. · doi:10.1097/00005392-200212000-00029
- 10.1034/j.1600-0412.2001.d01-9.x · doi:10.1034/j.1600-0412.2001.d01-9.x
- 10.7863/jum.1997.16.10.673 · doi:10.7863/jum.1997.16.10.673
- 10.1046/j.1469-0705.2002.00686.x · doi:10.1046/j.1469-0705.2002.00686.x
Cited by
Levator Trauma After Vaginal Delivery
Dietz, H. P., & Lanzarone, V. (2005) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000178779.62181.01 · Cited by 553
Self-citationUltrasound imaging of the pelvic floor. Part II: three‐dimensional or volume imaging
Dietz, H. P. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1072 · Cited by 399
Self-citationPelvic Organ Prolapse Quantification System (POP-Q) - a new era in pelvic prolapse staging.
(2011) · Europe PMC (PubMed Central) · Cited by 319
Ballooning of the levator hiatus
Dietz, H. P., Shek, C., De Leon, J., & Steensma, A. B. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5355 · Cited by 318
Self-citationPelvic floor ultrasound: a review
Dietz, H. P. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.08.018 · Cited by 276
Self-citationThe prevalence of major abnormalities of the levator ani in urogynaecological patients
Dietz, H., & Steensma, A. (2006) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2006.00819.x · Cited by 270
Self-citationQuantification of major morphological abnormalities of the levator ani
Dietz, H. P. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.3951 · Cited by 267
Self-citationKalache, K. D., Dückelmann, A. M., Michaelis, S. A. M., Lange, J., Cichon, G., & Dudenhausen, J. W. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.6294 · Cited by 262
DIETZ, H. P., FRANCO, A. V. M., SHEK, K. L., & KIRBY, A. (2012) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2011.01315.x · Cited by 158
“Each patient underwent an interview, a vaginal examination and translabial four-dimensional ultrasound (using GE Kretz Voluson 730 expert systems with RAB 8–4 MHz transducer; GE Kretz Medical Ultrasound, Zipf, Austria) to examine the pelvic floor, supine and after bladder emptying (21).”
MethodSelf-citationAbdool, Z., Lindeque, B. G., & Dietz, H. P. (2018) · International Urogynecology Journal · doi:10.1007/s00192-017-3530-1 · Cited by 20
Self-citationSzentimrey, Z., Ameri, G., Hong, C. X., Cheung, R. Y. K., Ukwatta, E., & Eltahawi, A. (2023) · Medical Physics · doi:10.1002/mp.16389 · Cited by 17
Brandt, C., & van Vuuren, E. C. J. (2019) · South African Journal of Physiotherapy · doi:10.4102/sajp.v75i1.472 · Cited by 11
Brandt, C., & van Vuuren, E. C. J. (2022) · Physiotherapy Canada · doi:10.3138/ptc-2020-0053 · Cited by 4
Metadata
- Authors
- Dietz, H. P.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2003-12-12
- Volume
- 23
- Issue
- 1
- Pages
- 80-92
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2170888284
- Cited by
- 356
- References
- 36
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.