The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Relationship between monitoring parameters and perinatal outcome in severe, early intrauterine growth restriction
Open accessAbstract
Objective: To investigate whether pathological changes in the umbilical artery (UA), ductus venosus (DV) and short‐term fetal heart variation are related to perinatal outcome in severe, early intrauterine growth restriction (IUGR). Methods: This multicenter, prospective, longitudinal, observational study was carried out in the Departments of Fetal Medicine and Obstetrics in Hamburg, Amsterdam, Utrecht and London. In 70 singleton pregnancies with IUGR fetuses, delivered at 26–33 weeks of gestation because of antepartum fetal distress, short‐term variation (STV) of fetal heart rate, pulsatility index of the fetal UA (UA PI) and DV pulsatility index for veins (DV PIV) were assessed at least weekly. The final measurement was performed within 24 h of delivery. Standard cut‐off levels (2 SD or 3 SD, absent flow or reversed flow) were used and new cut‐off levels were calculated by means of receiver–operating characteristics analysis. Adverse outcome was defined as perinatal death, cerebral hemorrhage (≥ Grade II) or bronchopulmonary dysplasia before discharge. The predictive value for adverse outcome was calculated for different cut‐off levels of the monitoring parameters, adjusted for gestational age (GA), by multivariate logistic regression analysis. Data were analyzed separately for three different time blocks, namely 8–14, 2–7 and 0–1 days before delivery. Results: Adverse perinatal outcome occurred in 18/70 (26%) infants. During the last 24 h before delivery DV PIV and UA PI were significantly higher and STV lower in the adverse outcome group, while 2–7 days before delivery only DV PIV was significantly higher. Adverse perinatal outcome could be predicted at 0–1 days before delivery by DV PIV at a cut‐off of three multiples of the SD (odds ratio (OR) 11.3; 95% CI 2.3–57) and GA (OR 0.4; 95% CI 0.3–0.8), at 2–7 days by DV PIV at 2 SD (OR 3.0; 95% CI 0.8–12) and GA (OR 0.5; 95% CI 0.3–0.8) and at 8–14 days by DV PIV at 2 SD (OR 3.9; 95% CI 0.8–20) and GA (OR 0.5; 95% CI 0.3–0.8). Other parameters did not contribute to the multivariate model. Conclusions: DV PIV measurement is the best predictor of perinatal outcome. This measurement may be useful in timing the delivery of early IUGR fetuses and in improving perinatal outcome, even when delivery may be indicated at an earlier GA. However, as GA was also an important factor influencing outcome, with poorer outcome at earlier gestation at delivery, this hypothesis needs to be tested in a multicenter, prospective, randomized trial. Copyright © 2004 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Components of heart rate variability — what they really mean and what we really measure
Malik, M., & Camm, A. J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91070-x · Cited by 575
Fetal biometry at 14–40 weeks' gestation
Snijders, R. J. M., & Nicolaides, K. H. (1994) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1994.04010034.x · Cited by 501
Monitoring of fetuses with intrauterine growth restriction: a longitudinal study
Hecher, K., Bilardo, C. M., Stigter, R. H., Ville, Y., Hackelöer, B. J., Kok, H. J., Senat, M. V., & Visser, G. H. A. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00590.x · Cited by 498
Self-citationFerrazzi, E., Bozzo, M., Rigano, S., Bellotti, M., Morabito, A., Pardi, G., Battaglia, F. C., & Galan, H. L. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2002.00627.x · Cited by 455
Hecher, K., Campbell, S., Doyle, P., Harrington, K., & Nicolaides, K. (1995) · Circulation · doi:10.1161/01.cir.91.1.129 · Cited by 444
Self-citationBaschat, A. A., Gembruch, U., & Harman, C. R. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00591.x · Cited by 435
Diagnostic Value of Blood Sampling in Fetuses with Growth Retardation
Pardi, G., Cetin, I., Marconi, A. M., Lanfranchi, A., Bozzetti, P., Farrazzi, E., Buscaglia, M., & Battaglia, F. C. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281004 · Cited by 347
Reference ranges for fetal venous and atrioventricular blood flow parameters
Hecher, K., Campbell, S., Snijders, R., & Nicolaides, K. (1994) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1994.04050381.x · Cited by 317
Self-citationThe GRIT Study Group, & article, P. A. L. A. T. E. O. T. (2003) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.02014.x · Cited by 305
Guinn, D. A., Atkinson, M. W., Sullivan, L., Lee, M., MacGregor, S., Parilla, B. V., Davies, J., Hanlon-Lundberg, K., Simpson, L., Stone, J., et al. (2001) · JAMA · doi:10.1001/jama.286.13.1581 · Cited by 298
Relationship between arterial and venous Doppler and perinatal outcome in fetal growth restriction
Baschat, A. A., Gembruch, U., Reiss, I., Gortner, L., Weiner, C. P., & Harman, C. R. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00284.x · Cited by 286
Bilardo, C. M., Nicolaides, K. H., & Campbell, S. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90833-s · Cited by 277
Self-citationDawes, G. S., Moulden, M., & Redman, C. W. G. (1992) · PubMed · Cited by 144
Arduini, D., Rizzo, G., & Romaninï, C. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(12)90882-0 · Cited by 143
Arduini, D., Rizzo, G., & Romanini, C. (1992) · PubMed · Cited by 123
Harrington, K., Carpenter, R. G., Nguyen, M., & Campbell, S. C. (1995) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1995.06010019.x · Cited by 120
INTRAUTERINE GROWTH RETARDATION: PREDICTION OF PERINATAL DISTRESS BY DOPPLER ULTRASOUND
Reuwer, P. J. H. M., RIETMAN, G. W., Sijmons, E. A., TIEL, M. W. M. V., & Bruinse, H. W. (1987) · The Lancet · doi:10.1016/s0140-6736(87)90956-1 · Cited by 114
Ribbert, L. S. M., Snijders, R. J. M., Nicolaides, K. H., & Visser, G. H. A. (1991) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1991.tb13489.x · Cited by 112
Self-citationVisser, G. H. A., Sadovsky, G., & Nicolaides, K. H. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90989-k · Cited by 105
Self-citationHecher, K., & Hackelöer, B. ‐. (1997) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1997.09030152.x · Cited by 99
Self-citationGuzmán, E., Vintzileos, A., MARTINS, M., Benito, C. W., Houlihan, C. M., & Hanley, M. L. (1996) · Obstetrics and Gynecology · doi:10.1016/0029-7844(96)00020-8 · Cited by 95
Romero, R. J., Kalache, K. D., & Kadar, N. R. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.0960-7692.2002.00653.x · Cited by 75
Bekedam, D. J., Visser, G. H. A., van der Zee, A. G. J., Snijders, R. J. M., & Poelmann-Weesjes, G. (1990) · Early Human Development · doi:10.1016/0378-3782(90)90008-7 · Cited by 75
Self-citationSénat, M., Schwärzler, P., Alcaïs, A., & Ville, Y. G. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00159.x · Cited by 73
Self-citationManagement of the growth-retarded fetus.
Visser, G. H. A., Stigter, R. H., & Bruinse, H. W. (1991) · PubMed · Cited by 16
Self-citation
Cited by
Figueras, F., & Gratacós, E. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000357592 · Cited by 796
Melamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Intrauterine growth restriction: new concepts in antenatal surveillance, diagnosis, and management
Figueras, F., & Gardosi, J. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.08.055 · Cited by 485
Predictors of neonatal outcome in early-onset placental dysfunction
Baschat, A. A., Cosmi, E., Bilardo, C. M., Wolf, H., Berg, C., Rigano, S., Germer, U., Moyano, D., Turan, S., Hartung, J., et al. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000253215.79121.75 · Cited by 485
Self-citationLees, C. C., Marlow, N., van Wassenaer-Leemhuis, A., Arabin, B., Bilardo, C. M., Brezinka, C., Calvert, S., Derks, J. B., Diemert, A., Duvekot, J. J., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)62049-3 · Cited by 479
Self-citation
Metadata
- Authors
- Bilardo, C. M., Wolf, H., Stigter, R. H., Ville, Y., Baez, E., Visser, G. H. A., & Hecher, K.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 119-125
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1976985815
- Cited by
- 278
- References
- 25
- FWCI
- 19.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.