The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Doppler application in the delivery timing of the preterm growth‐restricted fetus: another step in the right direction
Abstract
This article provides an opinion on a study of relationships between umbilical artery (UA) Doppler, ductus venosus (DV) Doppler, fetal heart rate variation, and perinatal outcome in preterm, intrauterine growth‐restricted (IUGR) fetuses published in the same issue of this journal by Bilardo and coworkers. Recent evidence on venous Doppler surveillance in preterm IUGR fetuses was also reviewed and discussed in the context of the study with a special emphasis on delivery timing. A search was conducted through MEDLINE and eight articles with similar inclusion criteria and reporting format of outcomes were identified. Numbers for perinatal mortality, intraventricular hemorrhage, respiratory distress syndrome, bronchopulmonary dysplasia and necrotizing enterocolitis (NEC) were extracted for cases where Doppler status was recorded in an identical format. Proportional distribution of outcomes was compared for fetuses with normal DV Doppler velocimetry, absent or reversed UA end‐diastolic velocity (UA A/REDV), elevated DV Doppler index (abnormal DV) and absence or reversal of atrial velocity in the DV (DV‐RAV). A total of 320 fetuses with normal and 202 with elevated DV Doppler indices were extracted. Of these fetuses, 101 with UA A/REDV only and 34 with DV‐RAV were identified. Perinatal mortality was 5.6% (16/282) with normal DV, 11.9% (12/101) with UA A/REDV, 38.8% (64/165) with abnormal DV and 41.2% (7/17) with DV‐RAV. With the exception of NEC, all complications were significantly more frequent with abnormal DV. With normal venous Doppler neonatal deaths account for most of the perinatal mortality, while with abnormal DV stillbirths and neonatal mortality are similar contributors to the significantly increased perinatal mortality. In conclusion, UA Doppler is a placental function test that provides important diagnostic and prognostic information in preterm IUGR. DV Doppler effectively identifies those preterm IUGR fetuses that are at high risk for adverse outcome (particularly stillbirth) at least 1 week before delivery, independent of the UA waveform. Relationships between perinatal outcome, arterial and venous Doppler status and gestational age require ongoing observational research effort. Randomized management trials are necessary to verify that delivery timing based on venous Doppler will impact on outcome in preterm IUGR. Copyright © 2004 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical significance of absent or reversed end diastolic velocity waveforms in umbilical artery
Karsdorp, V. H. M., van Vugt, J. M. G., van Geijn, H. P., Kostense, P. J., Arduim, D., Montenegro, N., & Todros, T. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90457-x · Cited by 445
The GRIT Study Group, & article, P. A. L. A. T. E. O. T. (2003) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.02014.x · Cited by 305
Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90783-7 · Cited by 243
Baschat, A. A., Gembruch, U., Weiner, C. P., & Harman, C. R. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.149 · Cited by 166
Self-citationBaschat, A. A., & Weiner, C. P. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(00)70505-9 · Cited by 151
Self-citation
Cited by
Fetal growth restriction: current knowledge
Nardozza, L. M. M., Caetano, A. C. R., Zamarian, A. C. P., Mazzola, J. B., Silva, C. P., Marçal, V. M. G., Lobo, T. F., Peixoto, A. B., & Araujo Júnior, E. (2017) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-017-4341-9 · Cited by 625
ACOG Practice Bulletin No. 204: Fetal Growth Restriction
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003070 · Cited by 562
Fetal Growth Restriction: ACOG Practice Bulletin, Number 227
(2021) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000004251 · Cited by 435
Progression of Doppler abnormalities in intrauterine growth restriction
Turan, O. M., Turan, S., Gungor, S., Berg, C., Moyano, D., Gembruch, U., Nicolaides, K. H., Harman, C. R., & Baschat, A. A. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5386 · Cited by 353
Self-citationDoppler assessment of the fetus with intrauterine growth restriction
Berkley, E., Chauhan, S. P., & Abuhamad, A. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2012.01.022 · Cited by 333
Metadata
- Authors
- Baschat, A. A.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 111-118
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2001482679
- Cited by
- 224
- References
- 5
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.