CoChat

Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep

Morrow, Robert J., Adamson, S. Lee, Bull, Shelley B., Knox Ritchie, J.W. · 1989 · American Journal of Obstetrics and Gynecology

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Absent diastolic velocity and reversed diastolic velocity have been observed in the umbilical artery of growth-retarded human fetuses by means of Doppler ultrasonography. Because the physiologic mechanism is unknown, the purpose of this study was to determine whether such waveform changes could be induced in sheep fetuses by embolization of the resistance vessels of the placenta. Seven chronically catheterized sheep fetuses were instrumented with Doppler crystals mounted on one umbilical artery. The placenta was progressively embolized from the fetal side with plastic microspheres. In all cases the umbilical arterial waveform showed a progression from normal to zero diastolic velocity with embolization. In six of seven animals diastolic velocity eventually reversed in direction before fetal death. We conclude that occlusion of placental arteries and arterioles in fetal sheep recreates the waveform changes observed in severely growth-retarded human fetuses.

Overview

Integrity signals

Registry

Crossref · 10.1016/0002-9378(89)90783-7

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. Griffin, 1983, Fetal and uteroplacental blood flow, Clin Obstet Gynecol, 10, 565

Cited by

See all 248

Metadata

Authors
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W.
Affiliations
University of Toronto (CA)
Venue
American Journal of Obstetrics and Gynecology
Publisher
Elsevier BV
Published
1989-10
Volume
161
Issue
4
Pages
1055-1060
ISSN
0002-9378 (ISSN-L)
OpenAlex
W1996640278
Cited by
243
References
24
Citations by year
2026: 4 · 2025: 6 · 2024: 4 · 2023: 5 · 2022: 12 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 9 · 2017: 9 · 2016: 8 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 10
FWCI
8.12
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • American Journal of Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Birth, Development, and Health
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Cardiovascular Conditions and Treatments
Keywords
umbilical artery, diastolic velocity, fetal growth restriction, fetal sheep, microspheres, fetal death, fetal hemodynamics
MeSH terms
Animals, Blood Flow Velocity, Blood Gas Analysis, Embolism, Female, Fetal Hypoxia, Fetus, Hemodynamics, Placenta, Pregnancy, Regional Blood Flow, Sheep, Ultrasonography, Umbilical Arteries, Vascular Resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep. https://app.cochat.ai/papers/10.1016/0002-9378(89)90783-7
The paper
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W. (1989). Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep. American Journal of Obstetrics and Gynecology. https://doi.org/10.1016/0002-9378(89)90783-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.