Cited by 31Cultural Heritage Materials AnalysisX-ray Spectroscopy and Fluorescence AnalysisElectron and X-Ray Spectroscopy Techniques

X‐ray fluorescence investigation of the shroud of turin

Morris, R. A., Schwalbe, L. A., London, J. R.·1980·X-Ray Spectrometry

Abstract

We present results of X‐ray fluorescence measurements on the Shroud of Turin. Quantitative estimates are given for the observed trace quantities of calcium, iron and strontium, and detection limits are established for other elements of potential interest. The calcium and strontium appear as uniform background distributions. Iron traces are observed in all of the data spectra but their local concentrations vary. Comparisons between image and off‐image areas reveal no differences, within the precision limits of the data, that would indicate the presence of pigments or dyes containing high‐C elements. In ‘blood’ stain regions the measurements show significantly higher concentrations of iron. However, the data do not allow a unique identification of the stain's origin. Quantitative comparisons are made between the shroud results and similar measurements on whole blood and Fe 2 O 3 stains.

Integrity signals

Registry

Crossref · 10.1002/xrs.1300090203

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Small dark spots visible in small quantities are small iron oxide particles.

    “Small dark spots were visible in small quantities and do not reflect at all under UV light, which leads us to believe these are small iron oxide particles (Morris et al. 1980;Schwalbe and Rogers 1982).”

    From Investigating a Dated Piece of the Shroud of Turin (2010) · cites this paper as Morris et al. 1980

Cited by

Sorted by citations

Authors
Morris, R. A., Schwalbe, L. A., & London, J. R.
Venue
X-Ray Spectrometry
Publisher
Wiley
Published
1980-04
Volume
9
Issue
2
Pages
40-47
ISSN
  • 0049-8246 (ISSN-L)
  • 1097-4539
OpenAlex
W2074979545
Cited by
31
References
0
Citations by year
2025: 4 · 2024: 1 · 2019: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2013: 2 · 2012: 2
FWCI
25.13
Type
journal article
Language
en
Open access
closed
Locations
X-Ray Spectrometry (publishedVersion)
Topics
  • Social Sciences › Arts and Humanities › Archeology › Cultural Heritage Materials Analysis
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques
Keywords
Shroud of Turin, X-ray fluorescence, trace elements, calcium, iron, strontium, bloodstains, detection limit

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review