The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Determination of the True Intraocular Pressure and Modulus of Elasticity of the Human Cornea in vivo
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Elasticity of soft tissues in simple elongation
Fung, Y. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.6.1532 · Cited by 1,029
APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
EHLERS, N., BRAMSEN, T., & SPERLING, S. (1975) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1975.tb01135.x · Cited by 931
Nonlinear material properties of intact cornea and sclera
Woo, S. L., KOBAYASHI, A. S., Schlegel, W. A., & Lawrence, C. (1972) · Experimental Eye Research · doi:10.1016/0014-4835(72)90139-x · Cited by 345
Intraocular Pressure and Glaucoma
Sommer, A. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90221-3 · Cited by 340
Cited by
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Shimmyo, M., Ross, A. J., Moy, A., & Mostafavi, R. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00424-0 · Cited by 375
Universal shape and pressure inside bubbles appearing in van der Waals heterostructures
Khestanova, E., Guinea, F., Fumagalli, L., Geim, A. K., & Grigorieva, I. V. (2016) · Nature Communications · doi:10.1038/ncomms12587 · Cited by 358
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056622 · Cited by 357
The materials science of collagen
Sherman, V. R., Yang, W., & Meyers, M. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.05.023 · Cited by 324
What Biomechanical Properties of the Cornea Are Relevant for the Clinician?
Kotecha, A. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.08.004 · Cited by 305
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Metadata
- Authors
- Orssengo, G.
- Venue
- Bulletin of Mathematical Biology
- Published
- 1999-05
- Volume
- 61
- Issue
- 3
- Pages
- 551-572
- ISSN
- 0092-8240 (ISSN-L)
- OpenAlex
- W2040781611
- Cited by
- 304
- References
- 5
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.