Full-field deformation of bovine cornea under constrained inflation conditions

Boyce, Brad L., Grazier, J. Mark, Jones, Reese E., Nguyen, Thao D.·2008·Biomaterials

Abstract

The viscoelastic response of bovine corneas was characterized using in vitro inflation (bulge) experiments combined with spatially-resolved deformation mapping via digital image correlation. A complex fixture conforming to the limbal annulus was developed to hold the attached sclera rigid while allowing deformation only in the cornea. A statistical set of experiments was performed for a pressure range of 3.6-8 kPa (27-60 mmHg), representing nominal bovine intraocular pressure (IOP) to acute glaucoma conditions. A broader pressure range of 0-32 kPa (0-240 mmHg) was also examined to characterize the nonlinear finite deformation behavior of the tissue. Results showed that for pressures near and above IOP, the majority of the deformation was localized in the limbus and peripheral regions, which left the central cornea largely undeformed. This observation was consistent with the known preferred circumferential alignment of collagen fibrils outside of the central cornea. In general, the inflation experiments observed viscoelastic behavior in the form of rate-dependent hysteresis in the pressure-deformation response of the apex of the cornea, creep in the apex deformation at a constant inflation pressure, and relaxation in the pressure response at a constant inflation volume. The 3.6-8 kPa (27-60 mmHg) pressure range produced small viscoelastic deformations and a nearly linear pressure-deformation response, which suggests that for physiological pressure ranges, the cornea can be app…

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2008.06.011

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Collagen crimp, in combination with elastic fibres in the peripheral cornea, may explain why this region is more pliable and absorbs intraocular pressure fluctuations, thus preventing deformation of the optically important central cornea.

    “In fact, collagen crimp, in combination with elastic fibres in the peripheral cornea, may explain why this region is more pliable and absorbs intraocular pressure fluctuations (Boyce et al., 2008), thus preventing deformation of the optically important central cornea.”

    From Corneal structure and transparency (2015) · cites this paper as Boyce et al., 2008

  • When pressure within the bovine eye is increased, the apex of the cornea moves forward the same amount as the mid periphery, so the central cornea is displaced forward as a whole maintaining its shape, with stretching in the peripheral cornea and limbus.

    “Boyce et al. [24] showed that, when pressure within the bovine eye is increased, the apex of the cornea moves forward the same amount as the mid periphery; in other words, the central cornea is displaced forward as a whole thereby maintaining its shape, and the stretching takes place in the peripheral cornea and limbus.”

Cited by

Sorted by citations

Authors
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D.
Affiliations
  • Sandia National Laboratories (US)
  • Sandia National Laboratories California (US)
  • Johns Hopkins University (US)
Corresponding author
Boyce, Brad L.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2008-10
Volume
29
Issue
28
Pages
3896-3904
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2017893554
Cited by
191
References
0
Citations by year
2026: 5 · 2025: 8 · 2024: 6 · 2023: 9 · 2022: 6 · 2021: 10 · 2020: 7 · 2019: 9 · 2018: 9 · 2017: 12 · 2016: 15 · 2015: 12 · 2014: 17 · 2013: 23 · 2012: 15
FWCI
5.86
Type
journal article
Language
en
Open access
closed
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
Keywords
bovine cornea, corneal viscoelasticity, intraocular pressure, acute glaucoma, collagen fibril alignment, hysteresis, creep, relaxation, corneal biomechanics
MeSH terms
Algorithms, Animals, Cattle, Cornea, Elasticity, Intraocular Pressure, Stress, Mechanical, Viscosity, Corneal Topography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review