The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
INTEGRINS AND STRETCH ACTIVATED ION CHANNELS; PUTATIVE COMPONENTS OF FUNCTIONAL CELL SURFACE MECHANORECEPTORS IN ARTICULAR CHONDROCYTES
Abstract
Perception of mechanical signals and the biological responses to such stimuli are fundamental properties of load bearing articular cartilage in diarthrodial joints. Chondrocytes utilize mechanical signals to synthesize an extracellular matrix capable of withstanding high loads and shear stresses. Recent studies have shown that chondrocytes undergo changes in shape and volume in a coordinated manner with load induced deformation of the matrix. These matrix changes, together with alterations in hydrostatic pressure, ionic and osmotic composition, interstitial fluid and streaming potentials are, in turn, perceived by chondrocytes. Chondrocyte responses to these stimuli are specific and well coordinated to bring about changes in gene expression, protein synthesis, matrix composition and ultimately biomechanical competence. In this hypothesis paper we propose a chondrocyte mechanoreceptor model incorporating key extracellular matrix macromolecules, integrins, mechanosensitive ion channels, the cytoskeleton and subcellular signal transduction pathways that maintain the chondrocyte phenotype, prevent chondrocyte apoptosis and regulate chondrocyte‐specific gene expression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure and Regulation of Voltage-Gated Ca 2+ Channels
Catterall, W. A. (2000) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.16.1.521 · Cited by 2,344
Mechanism of work-induced hypertrophy of skeletal muscle
GOLDBERG, A. L., ETLINGER, J. D., GOLDSPINK, D. F., & JABLECKI, C. (1975) · Medicine and Science in Sports and Exercise · doi:10.1249/00005768-197500730-00016 · Cited by 402
Cited by
In touch: plant responses to mechanical stimuli
Braam, J. (2005) · New Phytologist · doi:10.1111/j.1469-8137.2004.01263.x · Cited by 676
Mechanically activated ion channel Piezo1 modulates macrophage polarization and stiffness sensing
Atcha, H., Jairaman, A., Holt, J. R., Meli, V. S., Nagalla, R. R., Veerasubramanian, P. K., Brumm, K. T., Lim, H. E., Othy, S., Cahalan, M. D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23482-5 · Cited by 644
Cell Mechanics: Integrating Cell Responses to Mechanical Stimuli
Janmey, P. A., & McCulloch, C. A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151927 · Cited by 630
535 East 70th Street, C. R. B., Goldring, M., Otero, M., Plumb, D., Dragomir, C., Favero, M., EI Hachem, K., Hashimoto, K., Roach, H., Olivotto, E., et al. (2011) · European Cells and Materials · doi:10.22203/ecm.v021a16 · Cited by 489
Shakibaei, M., John, T., Schulze-Tanzil, G., Lehmann, I., & Mobasheri, A. (2007) · Biochemical Pharmacology · doi:10.1016/j.bcp.2007.01.005 · Cited by 364
Self-citation
Metadata
- Authors
- Mobasheri, A., Carter, S. D., Martín‐Vasallo, P., & Shakibaei, M.
- Venue
- Cell Biology International
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 26
- Issue
- 1
- Pages
- 1-18
- ISSN
- 1065-6995 (ISSN-L)
- 1095-8355
- OpenAlex
- W2022721848
- Cited by
- 216
- References
- 2
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: INTEGRINS AND STRETCH ACTIVATED ION CHANNELS; PUTATIVE COMPONENTS OF FUNCTIONAL CELL SURFACE MECHANORECEPTORS IN ARTICULAR CHONDROCYTES. https://app.cochat.ai/papers/10.1006/cbir.2001.0826
- The paper
- Mobasheri, A., Carter, S. D., Martín‐Vasallo, P., & Shakibaei, M. (2002). INTEGRINS AND STRETCH ACTIVATED ION CHANNELS; PUTATIVE COMPONENTS OF FUNCTIONAL CELL SURFACE MECHANORECEPTORS IN ARTICULAR CHONDROCYTES. Cell Biology International. https://doi.org/10.1006/cbir.2001.0826
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.