Intratracheal Inhalation vs Intratracheal Instillation: Differences in Particle Effects
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Our laboratory has developed a method of intratracheal inhalation whereby rats can be exposed to high aerosol concentrations, resulting in high lung particle burdens in a short time period with deposition occurring directly in the lower respiratory tract, thus avoiding many drawbacks of larger nose-only or whole body inhalation systems. In this report, we compare the response of rats exposed by intratracheal inhalation to "fine" (approximately 250 nm) and "ultrafine" (approximately 21 nm) titanium dioxide particles with rats exposed to similar doses by intratracheal instillation. Animals receiving particles through inhalation showed a decreased pulmonary response, measured by bronchoalveolar lavage parameters, in both severity and persistence, when compared with those receiving particles through instillation. These results demonstrate a difference in pulmonary response to an inhaled vs an instilled dose, which may be due to differences in dose rate, particle distribution, or altered clearance between the two methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Driscoll, K. E., & Maurer, J. K. (1991) · Toxicologic Pathology · doi:10.1177/0192623391019004-108 · Cited by 90 · cited 2×
“, 1991), and increased PMN influx (Oberdorster et al., 1990, 1992, 1994a,b; Driscoll and Maurer, 1991; Ferin et al., 1991) over the fine particle exposures.”
Background
Cited by
Kreyling, W. G., Semmler, M., Erbe, F., Mayer, P., Takenaka, S., Schulz, H., Oberdörster, G., & Ziesenis, A. (2002) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/00984100290071649 · Cited by 790
Blake, D. M., Maness, P.-C., Huang, Z., Wolfrum, E. J., Huang, J., & Jacoby, W. A. (1999) · Separation and Purification Methods · doi:10.1080/03602549909351643 · Cited by 568
Wang, J., Liu, Y., Jiao, F., Lao, F., Li, W., Gu, Y., Li, Y., Ge, C., Zhou, G., Li, B., et al. (2008) · Toxicology · doi:10.1016/j.tox.2008.09.014 · Cited by 450
Nanosafety Research—Are We on the Right Track?
Krug, H. F. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403367 · Cited by 421
Schins, R. P. F., Lightbody, J. H., Borm, P. J. A., Shi, T., Donaldson, K., & Stone, V. (2004) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2003.10.002 · Cited by 368
Metadata
- Authors
- Osier, M.
- Venue
- Fundamental and Applied Toxicology
- Publisher
- Elsevier BV
- Published
- 1997-12
- Volume
- 40
- Issue
- 2
- Pages
- 220-227
- ISSN
- 0272-0590 (ISSN-L)
- OpenAlex
- W2113713722
- Cited by
- 157
- References
- 1
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intratracheal Inhalation vs Intratracheal Instillation: Differences in Particle Effects. https://app.cochat.ai/papers/10.1006/faat.1997.2390
- The paper
- Osier, M. (1997). Intratracheal Inhalation vs Intratracheal Instillation: Differences in Particle Effects. Fundamental and Applied Toxicology. https://doi.org/10.1006/faat.1997.2390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.