HNCACB, a High-Sensitivity 3D NMR Experiment to Correlate Amide-Proton and Nitrogen Resonances with the Alpha- and Beta-Carbon Resonances in Proteins
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the level of fidelity for the standard pulses is low, constituting a significant source of signal losses, particularly for multiple simultaneous operations (11, 56, 57).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [57]
In the citing paper
“Note that the G5 shaped π pulse can replace all hard π pulses and some 13C shaped π pulses, with the exception of the Q3 pulses in the 3D HNCACB-type experiments23,24 (such as HNCACB, HN(CO)CACB, HNCA, HN(CO)CA).”
From Enhancing the sensitivity of multidimensional NMR experiments by using triply-compensated π pulses (2017) · cites this paper as [23]
In the citing paper
“Even simple 2D pulse sequences such as the 1H-15N HSQC20,21 and the 1H-13C HSQC22 experiments contain several hard π pulses (Figs. S2 and S3), and signal losses are exacerbated in through-bond23–25 and through-space22,26 triple-resonance experiments.”
From Enhancing the sensitivity of multidimensional NMR experiments by using triply-compensated π pulses (2017) · cites this paper as [23]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Still being checked.
Cited by
Atomic-resolution structure of a disease-relevant Aβ(1–42) amyloid fibril
Wälti, M. A., Ravotti, F., Arai, H., Glabe, C. G., Wall, J. S., Böckmann, A., Güntert, P., Meier, B. H., & Riek, R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1600749113 · Cited by 808
Calcium-induced conformational transition revealed by the solution structure of apo calmodulin
Zhang, M., Tanaka, T., & Ikura, M. (1995) · Nature Structural & Molecular Biology · doi:10.1038/nsb0995-758 · Cited by 692
Donne, D. G., Viles, J. H., Groth, D., Mehlhorn, I., James, T. L., Cohen, F. E., Prusiner, S. B., Wright, P. E., & Dyson, H. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13452 · Cited by 674
Salzmann, M., Pervushin, K., Wider, G., Senn, H., & Wüthrich, K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13585 · Cited by 646
Structural basis for Hif-1α/CBP recognition in the cellular hypoxic response
Dames, S. A., Martinez-Yamout, M., De Guzman, R. N., Dyson, H. J., & Wright, P. E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082121399 · Cited by 402
Metadata
- Authors
- Wittekind, M., & Mueller, L.
- Venue
- Journal of Magnetic Resonance, Series B
- Publisher
- Elsevier BV
- Published
- 1993-04
- Volume
- 101
- Issue
- 2
- Pages
- 201-205
- ISSN
- 1064-1866 (ISSN-L)
- OpenAlex
- W2022496873
- Cited by
- 859
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.