CoChat

High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging

Open access

The DOI matches its Crossref record; 86 of the 89 references it cites were found in a registry or an index, and 2 are not checked yet; 1 of the 52 sources its claims cite were checked for support.

Abstract

High-fidelity control of spin ensemble dynamics is essential to many fields, spanning from quantum computing to optical, coherent, and nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI). However, attaining robust and high-fidelity quantum spin operations remains an unmet challenge. Using a combination of an evolutionary algorithm and artificial intelligence, we designed time-optimal, radio frequency (RF) pulses with tunable spatial or temporal field inhomogeneity compensation and fidelity for unitary operations up to 0.9999. As a benchmark, we constructed a spin entanglement operator and a programmable quantum state creator for a weakly-coupled two-spin-1/2 system. We achieved high-fidelity transformations under multiple inhomogeneity sources. The newly designed RF pulses are more robust and less prone to imperfection than the commonly used shapes for basic liquid-state NMR experiments and reduce RF artifacts in MRI. This new strategy will enable the design of efficient quantum computing opera-tors as well as new spectroscopic and imaging techniques.

Verified 2026-11-21 · 2 references not checked yet

Overview

CoChat Summary

TL;DR

The authors introduce GENETICS-AI, an evolutionary-algorithm/AI framework that designs constant-amplitude RF pulses with customizable bandwidth, inhomogeneity compensation, and fidelity for spin-ensemble control. The generated pulses outperform standard rectangular/composite pulses in simulations and in NMR, MRI phantom, and ¹³CHCl₃ entanglement experiments, with reported fidelities up to 0.99999.

Key findings

  • GENETICS-AI generated RF pulses with constant amplitude and customizable bandwidth, RF inhomogeneity compensation, and operational fidelity; the OPS library contained ∼2,00,000 RF shapes, and several spin operations reached fidelity up to 0.99999.
  • For the weakly coupled two-spin-1/2 system of ¹³CHCl₃, the GEN-Entangler gave J-coupling compensation of ±10% for n = 1, ±30% for n = 2, and ±50% for n = 4; with n = 2 and compensation of ±20% for ω₁ and ±2 kHz for BW, the fidelity volume was approximately 100 times larger than a rectangular-pulse C-NOT entangler at maximum inhomogeneity, rising to 200 times at 0.98 fidelity, and the sequence was ∼62% shorter than the J-compensated C-NOT gate sequence.
  • Broadband pulses: universal π/2 and π pulses covered 40 kHz BW with lengths <300 μs, constant ω₁ = 25 kHz, and average fidelity 0.9999; ultra-broadband universal π/2 and π pulses reached 750 kHz BW (30 × ω₁) with ∼1.5 ms length; a broadband inversion pulse achieved fidelity 0.99999 with 274 μs duration, 100 kHz BW, and 25 kHz RF amplitude; adding 5 kHz (20%) numerical noise dropped fidelity by only 0.014 (0.999 to 0.985).
  • NMR/MRI applications: in GEN-HSQC, PFG-HSQC intensities were ∼0.8 near the ¹H carrier and dropped to ∼0.5 off-resonance relative to GEN-HSQC; at ±20% amplitude attenuation, PFG-HSQC amide resonances were barely observable while GEN-HSQC showed constant response; for 42 kDa PKA-C, GEN-HSQC detected additional amide peaks; band-selective pulses were less than 1/4 the duration of traditional band-selective pulses; GEN-SE phantom images remained high quality with fewer artifacts even at ±80% ω₁ inhomogeneity, and an ultra-broadband pulse required 6.57 mW versus 7.3 W for a corresponding rectangular pulse.

Methods

  • Design: GENETICS-AI combines iterative forward search (IFSA) and iterative self-correcting algorithms (ISCA) to search RF phase space and generate an Optimal Phase Surface (OPS) library; a neural network (PhaseNET) trained on this library predicts new RF shapes. The software was written in MATLAB R2018a and run on an Intel Core i7-7700K processor; fitness was defined as average operational fidelity over offset and ω₁ ranges.
  • Samples and experiments: ¹³CHCl₃ in CDCl₃; U-¹⁵N ubiquitin K48C mutant at 500 μM; 42 kDa PKA-C; U-¹³C-labeled maltose-binding protein; MRI phantom of two 4 mm glass beads in a 5 mm Shigemi tube. Spectrometers included Bruker 600 MHz for entanglement experiments, 850 MHz for protein NMR, and 900 MHz for MRI.
  • Analysis: simulated fidelity/offset/ω₁ profiles, quantum state tomography, 2D HSQC spectra, and 1D MRI images; GENETICS-AI pulses were compared with standard rectangular pulses, PFG-HSQC, and C-NOT entanglers using metrics including fidelity, bandwidth, pulse length, S/N, and intensity.

Limitations

  • Paper states: at the time, GENETICS-AI could design only pulses with constant amplitude or preselected amplitude shapes; future developments were planned to include RF pulse amplitude in the search space.
  • Paper states: the ultra-broadband pulse showed signal intensity loss due to relaxation during pulse execution; the 5 GHz biomolecular NMR pulses are hypothetical because commercially available ultra-high magnetic fields are limited to 1.2 GHz.
  • Evident from the text: computational cost is high (a 100-point OPS takes ∼12 hours; a 500-point shape grows to approximately a week; up to 2,000-point shapes were implemented), and MRI validation was performed on a phantom rather than in vivo, with NMR tests limited to selected proteins.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.21203/rs.3.rs-403351/v1

Cites

86 of 88 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Generation of spin entanglement for 13 CHCl3. (A) 13 CHCl3 used for validating the GEN-Entangler pulse sequence. (B) GEN-Entangler pulse sequence. All the pulses are global for both 1 H and 13 C nuclei. Pulses and delay parameters for different values of n are given in Table S1. (C) J response curve of entanglement fidelity for n = 1, 2, and 4. (D) and (E) RF shapes and corresponding fidelity profiles used for GEN-Entangler with n = 2. (F) Quantum state tomography for the real and imaginary part of the | αα 〉 pseudo pure state created for 1 H and 13 C nuclear spins. (G) Simulated iso-surface at 0.99 fidelity for the entanglement created with n = 2 (outer surface-yellow) and standard C-NOT entangler with rectangular-shaped pulse (inner surface-red). The quantum state tomography results for simulated inhomogeneities on the 0.99 fidelity iso-surface for both extreme values of all three variables are shown in blue. (H) Fidelity volume fraction of entanglement created with GEN-Entangler ( V GEN) over standard C-NOT with rectangular pulses ( V RECT) for fidelities of 0.995, 0.99, and 0.98. All experiments were performed on a Bruker 600 MHz spectrometer at 300 K.
Figure 1 Generation of spin entanglement for 13 CHCl3. (A) 13 CHCl3 used for validating the GEN-Entangler pulse sequence. (B) GEN-Entangler pulse sequence. All the pulses are global for both 1 H and 13 C nuclei. Pulses and delay parameters for different values of n are given in Table S1. (C) J response curve of entanglement fidelity for n = 1, 2, and 4. (D) and (E) RF shapes and corresponding fidelity profiles used for GEN-Entangler with n = 2. (F) Quantum state tomography for the real and imaginary part of the | αα 〉 pseudo pure state created for 1 H and 13 C nuclear spins. (G) Simulated iso-surface at 0.99 fidelity for the entanglement created with n = 2 (outer surface-yellow) and standard C-NOT entangler with rectangular-shaped pulse (inner surface-red). The quantum state tomography results for simulated inhomogeneities on the 0.99 fidelity iso-surface for both extreme values of all three variables are shown in blue. (H) Fidelity volume fraction of entanglement created with GEN-Entangler ( V GEN) over standard C-NOT with rectangular pulses ( V RECT) for fidelities of 0.995, 0.99, and 0.98. All experiments were performed on a Bruker 600 MHz spectrometer at 300 K.CC-BY-NC-ND · From the PDF
Figure 2 BB high-fidelity arbitrary flip angle pulses generated with GENETICS-AI. (A) OPS of a BB arbitrary state preparation with fidelity > 0.99999. The Y-axis represent the zenith angle ( ζ ) of the final state. The OPS was generated with an initial state fixed at | α 〉 and varying the ζ from 0 to π iteratively. The total nutation angle of the pulse was fixed at 8.68 π for all states. (B) OPS for arbitrary flipping operation with fidelity > 0.9999. The Y-axis represents the flip angle ( θ ) of the pulse. The OPS was created with θ as a target variable. The total nutation angle for the operation was fixed at 11.42 π . (C) Bloch sphere trajectories for the preparation of four different states (A, B, C, and D) using RF shapes from the OPS shown in (A). (D) Bloch sphere trajectories of two different flipping operations from A and A' to B and B' using RF shape from the OPS shown in (B). All trajectories are trimmed to show only 10% of the initial and final part. (E) RF shape of 113.5 ◦ universal flipping for a bandwidth of 50 kHz. The RF amplitude is constant (25 kHz). (F) 2D-fidelity response with offset and RF amplitude of the RF shape shown in (E).
Figure 2 BB high-fidelity arbitrary flip angle pulses generated with GENETICS-AI. (A) OPS of a BB arbitrary state preparation with fidelity > 0.99999. The Y-axis represent the zenith angle ( ζ ) of the final state. The OPS was generated with an initial state fixed at | α 〉 and varying the ζ from 0 to π iteratively. The total nutation angle of the pulse was fixed at 8.68 π for all states. (B) OPS for arbitrary flipping operation with fidelity > 0.9999. The Y-axis represents the flip angle ( θ ) of the pulse. The OPS was created with θ as a target variable. The total nutation angle for the operation was fixed at 11.42 π . (C) Bloch sphere trajectories for the preparation of four different states (A, B, C, and D) using RF shapes from the OPS shown in (A). (D) Bloch sphere trajectories of two different flipping operations from A and A' to B and B' using RF shape from the OPS shown in (B). All trajectories are trimmed to show only 10% of the initial and final part. (E) RF shape of 113.5 ◦ universal flipping for a bandwidth of 50 kHz. The RF amplitude is constant (25 kHz). (F) 2D-fidelity response with offset and RF amplitude of the RF shape shown in (E).CC-BY-NC-ND · From the PDF
Figure 3 BB universal pulses and comparison of GENETICS-AI refocusing pulses with previously reported shapes. (A) Plot of the 'Refocusing bandwidth-pulse length' for best performing GENETICS-AI pulses versus reported refocusing pulses. Refocusing BW of each pulse is calculated by averaging the offset responses of Mx and My magnetizations with a cutoff operational fidelity of 0.95. Each pulse is labeled with a short form and color-coded for the same family. Supplementary Table S2 shows the full names and relative reference for each pulse analyzed. The size of each dot represents the average operational fidelity of the pulse. Offset responses of a few selected RF shapes are shown in Figure S9. (B) Ultra-BB universal π /2 and (C), π pulse of BW 30 × ω 1. Amplitude shapes of these pulses are constant ( ω 1) with phase shapes shown on the left. Offset response of π and π /2 are shown for initial states Mz (middle). Simulated fidelity response with offset and RF amplitude are shown on the right panel.
Figure 3 BB universal pulses and comparison of GENETICS-AI refocusing pulses with previously reported shapes. (A) Plot of the 'Refocusing bandwidth-pulse length' for best performing GENETICS-AI pulses versus reported refocusing pulses. Refocusing BW of each pulse is calculated by averaging the offset responses of Mx and My magnetizations with a cutoff operational fidelity of 0.95. Each pulse is labeled with a short form and color-coded for the same family. Supplementary Table S2 shows the full names and relative reference for each pulse analyzed. The size of each dot represents the average operational fidelity of the pulse. Offset responses of a few selected RF shapes are shown in Figure S9. (B) Ultra-BB universal π /2 and (C), π pulse of BW 30 × ω 1. Amplitude shapes of these pulses are constant ( ω 1) with phase shapes shown on the left. Offset response of π and π /2 are shown for initial states Mz (middle). Simulated fidelity response with offset and RF amplitude are shown on the right panel.CC-BY-NC-ND · From the PDF
Figure 4 RF inhomogeneity compensated high-resolution multipulse NMR experiment. (A) GENETICS-AI shapes for universal π and π /2 pulses for 1 H (blue) and 15 N (red) channels. RF amplitudes were constant at 12.5 and 5.8 kHz for 1 H and 15 N channels, respectively. The pulse lengths for π /2 and π pulses were 488.6 and 509.8 μ s for 1 H and 483.8 and 524 μ s for 15 N. (B) Simulated fidelity response with offset and RF amplitude for 1 H (blue) and 15 N (red) for the pulse shapes in (A). The inner contour level indicates a fidelity of 0.99. (C) GENETICS-AI version of the HSQC (GEN-HSQC) spectrum of 15 N labeled K48C mutant of Ubiquitin recorded using calibrated amplitude values for 1 H (12.5 kHz) and 15 N (5.8 kHz) channels on a Bruker 850 MHz spectrometer at 300 K. The insets show the intensity comparison of the standard PFG-HSQC (using the Bruker pulse sequence-'hsqcetfpf3gpsi2') ( IRECT ) and GEN-HSQC ( IGEN ) at different RF amplitudes for selected residues. Left Y-axis shows the normalized peak intensities of standard (blue) and GEN-HSQC (red) relative to the calibrated reference spectra ( I 0 RECT and I 0 GEN ), whereas the right Y-axis represents the normalized intensity of standard HSQCs (blue) with respect to I 0 GEN . (D) GEN-HSQC spectra of 200 μ M 15 N labeled catalytic subunit of protein kinase A (42 kDa). The figure insets compare the intensity of various resonances recorded using GEN-HSQC (red) and PFG-HSQC (blue) of the HSQC experiment. Both experiments are recorded on a Bruker 850 MHz spectrometer at 273 K using 128 complex indirect points were acquired with 16 scans per FID and a 1.5 s relaxation delay. Maximum RF amplitudes were 16.67 kHz for 1 H and 7.7 kHz for 15 N.
Figure 4 RF inhomogeneity compensated high-resolution multipulse NMR experiment. (A) GENETICS-AI shapes for universal π and π /2 pulses for 1 H (blue) and 15 N (red) channels. RF amplitudes were constant at 12.5 and 5.8 kHz for 1 H and 15 N channels, respectively. The pulse lengths for π /2 and π pulses were 488.6 and 509.8 μ s for 1 H and 483.8 and 524 μ s for 15 N. (B) Simulated fidelity response with offset and RF amplitude for 1 H (blue) and 15 N (red) for the pulse shapes in (A). The inner contour level indicates a fidelity of 0.99. (C) GENETICS-AI version of the HSQC (GEN-HSQC) spectrum of 15 N labeled K48C mutant of Ubiquitin recorded using calibrated amplitude values for 1 H (12.5 kHz) and 15 N (5.8 kHz) channels on a Bruker 850 MHz spectrometer at 300 K. The insets show the intensity comparison of the standard PFG-HSQC (using the Bruker pulse sequence-'hsqcetfpf3gpsi2') ( IRECT ) and GEN-HSQC ( IGEN ) at different RF amplitudes for selected residues. Left Y-axis shows the normalized peak intensities of standard (blue) and GEN-HSQC (red) relative to the calibrated reference spectra ( I 0 RECT and I 0 GEN ), whereas the right Y-axis represents the normalized intensity of standard HSQCs (blue) with respect to I 0 GEN . (D) GEN-HSQC spectra of 200 μ M 15 N labeled catalytic subunit of protein kinase A (42 kDa). The figure insets compare the intensity of various resonances recorded using GEN-HSQC (red) and PFG-HSQC (blue) of the HSQC experiment. Both experiments are recorded on a Bruker 850 MHz spectrometer at 273 K using 128 complex indirect points were acquired with 16 scans per FID and a 1.5 s relaxation delay. Maximum RF amplitudes were 16.67 kHz for 1 H and 7.7 kHz for 15 N.CC-BY-NC-ND · From the PDF
Figure 5 Band-selective excitation and inversion pulses with (A) excitation on the left half of BW and (B) Inversion on left half of the BW. Note that to observe Mz and -Mz, we added a reading pulse (90 o ) prior to acquisition. (C) Excitation on left half and inversion on right half of the BW, simultaneously. The excitation/inversion half of the offset response can be swapped by inverting the phase array. An RF amplitude of 25 kHz was used for the simulation. Experimental verification was performed using a uniformly 13 C labeled maltose binding protein (MBP) on an 850 MHz spectrometer. The band-selective excitation/inversion of aliphatic/carbonyl regions of the MBP are shown in the right column. The reference of the 13 C spectra is shown in blue, whereas the spectra obtained with different GENETICS-AI band-selective operations are shown in red.
Figure 5 Band-selective excitation and inversion pulses with (A) excitation on the left half of BW and (B) Inversion on left half of the BW. Note that to observe Mz and -Mz, we added a reading pulse (90 o ) prior to acquisition. (C) Excitation on left half and inversion on right half of the BW, simultaneously. The excitation/inversion half of the offset response can be swapped by inverting the phase array. An RF amplitude of 25 kHz was used for the simulation. Experimental verification was performed using a uniformly 13 C labeled maltose binding protein (MBP) on an 850 MHz spectrometer. The band-selective excitation/inversion of aliphatic/carbonyl regions of the MBP are shown in the right column. The reference of the 13 C spectra is shown in blue, whereas the spectra obtained with different GENETICS-AI band-selective operations are shown in red.CC-BY-NC-ND · From the PDF
Figure 6 SE imaging under ultra-high RF inhomogeneity. (A) SE pulse sequence used for imaging. The π /2 and π pulses are replaced with GENETICS-AI pulses for GEN-SE sequence. The amplitude of the pulses is constant (16.67 kHz) and pulse lengths for π /2 and π pulses are 437 and 567 μ s, respectively. The maximum RF amplitude tolerance level ( Delta1ω max 1 ) of these pulses were ± 80%. The gradient strengths (G1 and G2) for all the experiments were set at 50% (3.3 G cm -1 ). (B) Diagram of phantom and coil geometry. The phantom consists of two glass beads of diameter 4 mm in a 5 mm Shigemi tube filled with 10% D2O and 90% H2O. (C) 1D image of the phantom using the pulse sequence in (A). (D) RF inhomogeneity response of 1D imaging using standard rectangular-shaped pulses of amplitude 16.67 kHz. (E) Same as (D) using GENETICS-AI pulses. The RF shapes and their fidelity profiles are shown in Figure S17. The experiments were performed in a Bruker 900 MHz NMR spectrometer.
Figure 6 SE imaging under ultra-high RF inhomogeneity. (A) SE pulse sequence used for imaging. The π /2 and π pulses are replaced with GENETICS-AI pulses for GEN-SE sequence. The amplitude of the pulses is constant (16.67 kHz) and pulse lengths for π /2 and π pulses are 437 and 567 μ s, respectively. The maximum RF amplitude tolerance level ( Delta1ω max 1 ) of these pulses were ± 80%. The gradient strengths (G1 and G2) for all the experiments were set at 50% (3.3 G cm -1 ). (B) Diagram of phantom and coil geometry. The phantom consists of two glass beads of diameter 4 mm in a 5 mm Shigemi tube filled with 10% D2O and 90% H2O. (C) 1D image of the phantom using the pulse sequence in (A). (D) RF inhomogeneity response of 1D imaging using standard rectangular-shaped pulses of amplitude 16.67 kHz. (E) Same as (D) using GENETICS-AI pulses. The RF shapes and their fidelity profiles are shown in Figure S17. The experiments were performed in a Bruker 900 MHz NMR spectrometer.CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

1 Valid · 1 Not valid · 22 Not checked · 85 Own results and interpretations

63 more claims

Create a free account to see all 109 claims and to verify the 48 references still open.

See all claims — free account
  • It may state two separate claims as one. 28
  • Probably not a substantial claim. 15

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 88 references

Research works printed but not linked: 3

  1. Cavanagh J, Fairbrother WJ, Palmer AG, Rance M, Skelton NJ. 2007. Protein NMR spectroscopy: principles and practice, 2nd ed. Cambridge, MA: Academic Press. p. 1-888.
  2. Zheng A, Liu S-B, Deng F. 2017. 31P NMR chemical shifts of phos- phorus probes as reliable and practical acidity scales for solid and liquid catalysts. Chem Rev. 117(19):12475-12531.
  3. Vinding MS, Skyum B, Sangill R, Lund TE. 2019. Ultrafast (mil- liseconds), multidimensional RF pulse design with deep learn- ing. Magn Reson Med. 82(2):586-599.

Cited by

See all 24

Metadata

Authors
Manu, V. S., Pavuluri, K., Mullen, M., Garwood, M., & Veglia, G.
Affiliations
  • University of Minnesota
  • Mayo Clinic (US)
  • University of Minnesota (US)
Corresponding author
Garwood, Michael
Venue
PNAS Nexus
Published
2021-04-20
Volume
1
Issue
4
Pages
pgac133-pgac133
ISSN
2752-6542 (ISSN-L)
OpenAlex
W4289885698
Cited by
24
References
89
Citations by year
2026: 9 · 2025: 7 · 2024: 4 · 2023: 3 · 2022: 1
FWCI
1.30
Type
journal article
Language
en
Open access
Locations
  • PNAS Nexus (publishedVersion, cc-by-nc-nd)
  • Research Square (submittedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
Funders
  • National Institutes of Health
  • National Heart, Lung, and Blood Institute (R01HL144130)
  • National Institute of General Medical Sciences (R01GM064742, R01GM100310)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
Keywords
spin entanglement, magnetic resonance imaging, quantum computing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging. https://app.cochat.ai/papers/10.21203/rs.3.rs-403351/v1
The paper
Manu, V. S., Pavuluri, K., Mullen, M., Garwood, M., & Veglia, G. (2021). High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging. PNAS Nexus. https://doi.org/10.21203/rs.3.rs-403351/v1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.