The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Uniform-Penalty Inversion of Multiexponential Decay Data
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
Provencher, S. W. (1982) · Computer Physics Communications · doi:10.1016/0010-4655(82)90173-4 · Cited by 2,701
In vivo measurement of T2 distributions and water contents in normal human brain
Whittall, K. P., Mackay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 793
Quantitative interpretation of NMR relaxation data
Whittall, K. P., & MacKay, A. L. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90011-5 · Cited by 628
Analysis of biological NMR relaxation data with continuous distributions of relaxation times
Kroeker, R. M., & Mark Henkelman, R. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90074-0 · Cited by 210
Criteria for analysis of multicomponent tissue T2 relaxation data
Graham, S. J., Stanchev, P. L., & Bronskill, M. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350315 · Cited by 179
Gallegos, D. P., & Smith, D. M. (1988) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(88)90297-4 · Cited by 174
Investigation of analysis techniques for complicated NMR relaxation data
Whittall, K. P., Bronskill, M. J., & Henkelman, R. M. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90213-d · Cited by 113
Characterization of fluid distributions in porous media by NMR techniques
Liaw, H., Kulkarni, R. N., Chen, S., & Watson, A. T. (1996) · AIChE Journal · doi:10.1002/aic.690420223 · Cited by 81
Cited by
T1–T2 Correlation Spectra Obtained Using a Fast Two-Dimensional Laplace Inversion
Song, Y.-Q., Venkataramanan, L., Hürlimann, M. D., Flaum, M., Frulla, P., & Straley, C. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2474 · Cited by 751
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Quantification of increased cellularity during inflammatory demyelination
Wang, Y., Wang, Q., Haldar, J. P., Yeh, F.-C., Xie, M., Sun, P., Tu, T.-W., Trinkaus, K., Klein, R. S., Cross, A. H., et al. (2011) · Brain · doi:10.1093/brain/awr307 · Cited by 384
NMR cryoporometry: Principles, applications and potential
Petrov, O. V., & Furó, I. (2009) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.06.001 · Cited by 348
Wang, Q., Wang, Y., Liu, J., Sutphen, C. L., Cruchaga, C., Blazey, T., Gordon, B. A., Su, Y., Chen, C., Shimony, J. S., et al. (2019) · NeuroImage: Clinical · doi:10.1016/j.nicl.2019.101767 · Cited by 63
Metadata
- Authors
- Borgia, G. C., Brown, R. J. S., & Fantazzini, P.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 1998-05
- Volume
- 132
- Issue
- 1
- Pages
- 65-77
- ISSN
- 1090-7807 (ISSN-L)
- OpenAlex
- W2010466247
- Cited by
- 432
- References
- 10
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uniform-Penalty Inversion of Multiexponential Decay Data. https://app.cochat.ai/papers/10.1006/jmre.1998.1387
- The paper
- Borgia, G. C., Brown, R. J. S., & Fantazzini, P. (1998). Uniform-Penalty Inversion of Multiexponential Decay Data. Journal of Magnetic Resonance. https://doi.org/10.1006/jmre.1998.1387
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.