Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record.

Criteria for analysis of multicomponent tissue T2 relaxation data

Graham, Simon J., Stanchev, Peter L., Bronskill, Michael J.·1996·Magnetic Resonance in Medicine

Abstract

Monte Carlo simulations were performed to determine whether the multicomponent T2 distribution of tissue can be estimated accurately from T2 decay data acquired in vivo. Simulated data were generated for white matter, fast twitch muscle, and breast tissue. The signal‐to‐noise ratio, number of data samples, and minimum echo time were varied from the experimental conditions currently achievable with MRI to those achievable for in vitro experiments. Data were fitted by a distribution of T2 values using the T2NNLS algorithm, and statistics characterizing the estimated T2 components were determined. Current MRI techniques were found to provide conditions insufficient for accurate multicomponent T2 analysis on a pixel‐by‐pixel basis. However, volume localization methods that measure T2 decay from a large volume of interest have potential for this analysis. These results illustrate a general framework for development of new techniques to measure T2 decay accurately in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910350315

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Graham, S. J., Stanchev, P. L., & Bronskill, M. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-03
Volume
35
Issue
3
Pages
370-378
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1974082131
Cited by
179
References
0
FWCI
5.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Criteria for analysis of multicomponent tissue T2 relaxation data. https://app.cochat.ai/papers/10.1002/mrm.1910350315
The paper
Graham, S. J., Stanchev, P. L., & Bronskill, M. J. (1996). Criteria for analysis of multicomponent tissue T2 relaxation data. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350315

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.