The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurements of the Temporal fMRI Response of the Human Auditory Cortex to Trains of Tones
Open accessAbstract
Averaged single trials (AST) allowed the functional magnetic resonance imaging (fMRI) response to auditory stimuli to be measured at high temporal (1 s) and spatial (0.1 cm3) resolution. Using this paradigm we investigated the transient signal response to 100-ms tone bursts in trains of between 100 ms and 25.5 s in total duration. We have demonstrated that the fMRI response to such auditory stimuli is approximately linear for trains of 6 s and longer, but that shorter stimuli produce signals that are larger than might be expected from the response to the longer stimuli. This nonlinear behavior can be modeled if an adaptive response to each stimulus is assumed. A study using a novel paradigm was also performed in order to study the influence of scanner noise during fMRI experiments on the auditory system response to tones. This study demonstrated that the temporal response to 700-ms tone stimuli is modified when performed in the presence of scanner gradient noise, the modification being a small but significant increase (P < 0.05) in the magnitude of the response. Finally the ability to measure the onset of functional activation using the AST method was examined. It was found, with the aid of computer simulation that a sampling rate of one image per second is adequate to distinguish temporal responses. Using the data acquired in this study, onset times were calculated for the auditory cortex, and these results are consistent with current models of functional activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Cited by
Logothetis, N. K., & Wandell, B. A. (2004) · Annual Review of Physiology · doi:10.1146/annurev.physiol.66.082602.092845 · Cited by 1,568
Deconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,386
Modeling the hemodynamic response to brain activation
Buxton, R. B., Uludağ, K., Dubowitz, D. J., & Liu, T. T. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.013 · Cited by 1,229
What does fMRI tell us about neuronal activity?
Heeger, D. J., & Ress, D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn730 · Cited by 1,085
Miezin, F. M., Maccotta, L., Ollinger, J. M., Petersen, S. E., & Buckner, R. L. (2000) · NeuroImage · doi:10.1006/nimg.2000.0568 · Cited by 944
Metadata
- Authors
- Robson, M. D., Dorosz, J. L., & Gore, J. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 1998-04
- Volume
- 7
- Issue
- 3
- Pages
- 185-198
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1972223851
- Cited by
- 181
- References
- 1
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of the Temporal fMRI Response of the Human Auditory Cortex to Trains of Tones. https://app.cochat.ai/papers/10.1006/nimg.1998.0322
- The paper
- Robson, M. D., Dorosz, J. L., & Gore, J. C. (1998). Measurements of the Temporal fMRI Response of the Human Auditory Cortex to Trains of Tones. NeuroImage. https://doi.org/10.1006/nimg.1998.0322
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.