Measurements of the Temporal fMRI Response of the Human Auditory Cortex to Trains of Tones
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Averaged single trials (AST) allowed the functional magnetic resonance imaging (fMRI) response to auditory stimuli to be measured at high temporal (1 s) and spatial (0.1 cm3) resolution. Using this paradigm we investigated the transient signal response to 100-ms tone bursts in trains of between 100 ms and 25.5 s in total duration. We have demonstrated that the fMRI response to such auditory stimuli is approximately linear for trains of 6 s and longer, but that shorter stimuli produce signals that are larger than might be expected from the response to the longer stimuli. This nonlinear behavior can be modeled if an adaptive response to each stimulus is assumed. A study using a novel paradigm was also performed in order to study the influence of scanner noise during fMRI experiments on the auditory system response to tones. This study demonstrated that the temporal response to 700-ms tone stimuli is modified when performed in the presence of scanner gradient noise, the modification being a small but significant increase (P < 0.05) in the magnitude of the response. Finally the ability to measure the onset of functional activation using the AST method was examined. It was found, with the aid of computer simulation that a sampling rate of one image per second is adequate to distinguish temporal responses. Using the data acquired in this study, onset times were calculated for the auditory cortex, and these results are consistent with current models of functional activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cohen, J., MacWhinney, B., Flatt, M., & Provost, J. (1993) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03204507 · Cited by 2,802 · cited 1×
“Auditory stimuli were generated using SoundSculptor II (shareware) running on a Macintosh Power PC (Apple Computer, Cupertino, CA) and presented to the subject via a similar computer running PsyScope (Cohen et al., 1993) and magnetcompatible headphones (Resonant Technology Inc., Northridge, CA).”
MethodLinear Systems Analysis of Functional Magnetic Resonance Imaging in Human V1
Boynton, G. M., Engel, S. A., Glover, G. H., & Heeger, D. J. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04207.1996 · Cited by 2,314 · cited 8×
“The signal changes of the fMRI response can be examined at high temporal resolution through the use of averaged single trials (AST) (Ernst and Hennig, 1994; Buckner et al., 1996; Boynton et al., 1996; Janz et al., 1997; McCarthy et al., 1997).”
BackgroundMethodResultInfluentialProcessing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763 · cited 1×
“Although less efficient for localizing activations than ''block'' averaging (Bandettini et al, 1993) this approach does allow the temporal intensity profile of individual voxels to be examined with a high signal to noise ratio (SNR) at a temporal resolution of around 1 s (or better) (Ernst and…”
BackgroundTheory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198 · cited 2×
“Our findings are consistent with previous suggestions that large signal changes may be from larger veins and venules (Yablonskiy and Haacke, 1994; Lai et al., 1993; Kennan et al., 1994) and that the changes in intensity appear later (ϩ700 ms) in these vessels.”
ResultJosephs, O., Turner, R., & Friston, K. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:4<243::aid-hbm7>3.0.co;2-3 · Cited by 694
Buckner, R. L., Bandettini, P. A., O’Craven, K. M., Savoy, R. L., Petersen, S. E., Raichle, M. E., & Rosen, B. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14878 · Cited by 577 · cited 5×
“The signal changes of the fMRI response can be examined at high temporal resolution through the use of averaged single trials (AST) (Ernst and Hennig, 1994; Buckner et al., 1996; Boynton et al., 1996; Janz et al., 1997; McCarthy et al., 1997).”
MethodInfluentialIntravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524 · cited 2×
“Our findings are consistent with previous suggestions that large signal changes may be from larger veins and venules (Yablonskiy and Haacke, 1994; Lai et al., 1993; Kennan et al., 1994) and that the changes in intensity appear later (ϩ700 ms) in these vessels.”
ResultSelf-citationSensitivity Enhancement in Magnetic Resonance
ERNST, R. R. (1966) · Advances in Magnetic and Optical Resonance · doi:10.1016/b978-1-4832-3115-0.50008-9 · Cited by 488 · cited 2×
“The SNR obtainable at each TR was calculated assuming the use of the Ernst angle (Ernst, 1966), which maximizes the signal, and yields”
MethodMcCarthy, G., Luby, M., Gore, J., & Goldman-Rakic, P. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.3.1630 · Cited by 459 · cited 6×
“The signal changes of the fMRI response can be examined at high temporal resolution through the use of averaged single trials (AST) (Ernst and Hennig, 1994; Buckner et al., 1996; Boynton et al., 1996; Janz et al., 1997; McCarthy et al., 1997).”
BackgroundInfluentialSelf-citationLai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390 · cited 2×
“Our findings are consistent with previous suggestions that large signal changes may be from larger veins and venules (Yablonskiy and Haacke, 1994; Lai et al., 1993; Kennan et al., 1994) and that the changes in intensity appear later (ϩ700 ms) in these vessels.”
Result
Cited by
Logothetis, N. K., & Wandell, B. A. (2004) · Annual Review of Physiology · doi:10.1146/annurev.physiol.66.082602.092845 · Cited by 1,568
Deconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,386
Modeling the hemodynamic response to brain activation
Buxton, R. B., Uludağ, K., Dubowitz, D. J., & Liu, T. T. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.013 · Cited by 1,229
What does fMRI tell us about neuronal activity?
Heeger, D. J., & Ress, D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn730 · Cited by 1,085
Miezin, F. M., Maccotta, L., Ollinger, J. M., Petersen, S. E., & Buckner, R. L. (2000) · NeuroImage · doi:10.1006/nimg.2000.0568 · Cited by 944
A multisensory investigation of the functional significance of the “pain matrix”
Mouraux, A., Diukova, A., Lee, M. C., Wise, R. G., & Iannetti, G. D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.084 · Cited by 559
An Event-related Functional MRI Study of the Stroop Color Word Interference Task
Leung, H.-C. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.6.552 · Cited by 448
An Event-related Neuroimaging Study Distinguishing Form and Content in Sentence Processing
Ni, W., Constable, R. T., Mencl, W. E., Pugh, K. R., Fulbright, R. K., Shaywitz, S. E., Shaywitz, B. A., Gore, J. C., & Shankweiler, D. (2000) · Journal of Cognitive Neuroscience · doi:10.1162/08989290051137648 · Cited by 387
Self-citationIsolation of a Central Bottleneck of Information Processing with Time-Resolved fMRI
Dux, P. E., Ivanoff, J., Asplund, C. L., & Marois, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.11.009 · Cited by 362
Functional anatomy of pitch memory—an fMRI study with sparse temporal sampling
Gaab, N., Gaser, C., Zaehle, T., Jancke, L., & Schlaug, G. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00224-6 · Cited by 335
Statistical Analysis of fMRI Time-Series: A Critical Review of the GLM Approach
Monti, M. (2011) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00028 · Cited by 321
Melcher, J. R., Sigalovsky, I. S., Guinan, J. J., & Levine, R. A. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.2.1058 · Cited by 308
Event-Related fMRI of the Auditory Cortex
Belin, P., Zatorre, R. J., Hoge, R., Evans, A. C., & Pike, B. (1999) · NeuroImage · doi:10.1006/nimg.1999.0480 · Cited by 293
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
Silva, A. C., & Koretsky, A. P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.222561899 · Cited by 269
Impaired face processing in autism: Fact or artifact?
Jemel, B., Mottron, L., & Dawson, M. (2006) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-005-0050-5 · Cited by 246
Parsing Pain Perception Between Nociceptive Representation and Magnitude Estimation
Baliki, M. N., Geha, P. Y., & Apkarian, A. V. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91100.2008 · Cited by 244
Event-related fMRI of auditory and visual oddball tasks
Stevens, A. A., Skudlarski, P., Gatenby, J. C., & Gore, J. C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00128-4 · Cited by 234
Self-citationSpatiotemporal Pattern of Neural Processing in the Human Auditory Cortex
Seifritz, E., Esposito, F., Hennel, F., Mustovic, H., Neuhoff, J. G., Bilecen, D., Tedeschi, G., Scheffler, K., & Di Salle, F. (2002) · Science · doi:10.1126/science.1074355 · Cited by 213
Harms, M. P., & Melcher, J. R. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1433 · Cited by 182
“Robson et al. (1998) found that the cortical fMRI response to the tone burst train could be fairly well described by a model in which there is a response to each burst in a train, but the magnitude of the response decreases progressively with each successive burst until a steady-state response…”
BackgroundMethodAcoustic noise and functional magnetic resonance imaging: Current strategies and future prospects
Amaro, E., Williams, S. C. R., Shergill, S. S., Fu, C. H. Y., MacSweeney, M., Picchioni, M. M., Brammer, M. J., & McGuire, P. K. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10186 · Cited by 175
“Therefore, the stimulus presentation time available with this design is usually in the range of 1–2 seconds (109,110).”
BackgroundNelissen, K., Vanduffel, W., & Orban, G. A. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0824-06.2006 · Cited by 165
“It has been well documented that the hemodynamic response function (HRF) differs between cortical regions, although it is unclear how much of these differences reflect differences in neuronal properties or differences in vasculature (Schacter et al., 1997; Buckner et al., 1998; Robson et al., 1998; Miezin et al., 2000…”
BackgroundMethodHorovitz, S. G., Skudlarski, P., & Gore, J. C. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00496-4 · Cited by 159
Self-citationAn event-related fMRI study of implicit phrase-level syntactic and semantic processing
Kang, A. M., Constable, R. T., Gore, J. C., & Avrutin, S. (1999) · NeuroImage · doi:10.1006/nimg.1999.0493 · Cited by 136
“The activation time-courses can also be correated to reference hemodynamic wave functions (Frison et al., 1998; Josephs et al., 1997; Ni et al., in press; obson et al., 1998).”
BackgroundSelf-citation
Metadata
- Authors
- Robson, M. D., Dorosz, J. L., & Gore, J. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 1998-04
- Volume
- 7
- Issue
- 3
- Pages
- 185-198
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1972223851
- Cited by
- 181
- References
- 18
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.