Peltier Heat Flux Sensor for Cryogenic Use
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Preliminary experimental results show that an output voltage of the typical Peltier element is 5±10 times higher than the conventional heat ¯ux sensors at 77 K, and indicate a possible use of the Peltier element for cryogenic applications.”
From Performance of Peltier elements as a cryogenic heat flux sensor at temperatures down to 60 K (2001) · cites this paper as [4]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 4
- M. Kichnir, J.D. Gonczy and J.L. Tague, Measuring heat leak with a heat meter, “Advances in Cryogenic Engineering 31”, Plenum Press, New York (1988), p 1285.
- J.D. Gonczy, M. Kuchnir, T.H. Nicol, R.C. Nieman and R.J. Powers, Heat leak measurement facility, “Advances in Cryogenic Engineering 31”, Plenum Press, New York (1988), p 1291.
- H.J. Goldsmid. “Thermoelectric refrigeration”, Plenum Press, New York (1964) · DOI · Paper page
- S. Yamaguchi, H. Nakamura, K. Ikeda, T. Sakurai, I. Yoshida, S. Tanuma, S. Tobise and K. Koumoto, Peltier current lead experiments with a thermoelectric semiconductor near 77 K, Proceedings of MT-15: 855–858 (1998)
Cited by
Performance of Peltier elements as a cryogenic heat flux sensor at temperatures down to 60 K
Haruyama, T. (2001) · Cryogenics · doi:10.1016/s0011-2275(01)00081-9 · Cited by 25
Self-citation
Metadata
- Authors
- Haruyama, T.
- Venue
- Advances in Cryogenic Engineering
- Publisher
- Springer US
- Published
- 2000
- Pages
- 1897-1904
- Cited by
- 4
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peltier Heat Flux Sensor for Cryogenic Use. https://app.cochat.ai/papers/10.1007/978-1-4615-4215-5_120
- The paper
- Haruyama, T. (2000). Peltier Heat Flux Sensor for Cryogenic Use. Advances in Cryogenic Engineering. https://doi.org/10.1007/978-1-4615-4215-5_120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.