The DOI matches its Crossref record.
Advances in Cryogenic Engineering
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The experimental results of Hawks et al. exhibited excellent agreement with the reported data, validating the accuracy and reliability of the apparatus.
“The experimental results exhibited excellent agreement with the reported data, thereby validating the accuracy and reliability of the apparatus.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
The Hawks et al. system utilized a gallium-doped germanium pyrometer as the radiation detector.
“utilized a gallium-doped germanium pyrometer as the radiation detector.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
Hawks et al. (1971) developed a radiation measurement apparatus based on the radiometric method.
“In 1971, Hawks et al. [44] at Purdue University developed a radiation measurement apparatus based on the radiometric method.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
The pyrometer converted radiation signals from both the sample and the reference blackbody into voltage outputs, from which the sample emissivity was calculated.
“The pyrometer converted the radiation signals from both the sample and the reference blackbody into voltage outputs, from which the sample emissivity was calculated.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
To minimize background interference, all internal chamber walls were coated with a high-emissivity black layer.
“To minimize background interference, all internal chamber walls were coated with a high-emissivity black layer.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.
“Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
Hawks et al. measured the emissivity of several materials over the 5-100 K temperature range, including aluminum, copper, stainless steel, and black-coated copper.
“Using this system, the team measured the emissivity of several materials over the 5-100 K temperature range, including aluminum, copper, stainless steel, and black-coated copper.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
The Hawks et al. system employed liquid helium to establish a cryogenic environment.
“The system employed a liquid-helium to establish a cryogenic environment”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
The management of background noise has advanced from simple subtraction to complex modeling and active adjustment, thereby enhancing the accuracy of testing systems.
“Furthermore, the management of background noise has advanced from simple subtraction [44] to complex modeling and active adjustment [26,55], thereby enhancing the accuracy of testing systems.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [44]
Citations
Cited by
Sorted by citations
Radebaugh, R. (2016) · Handbook of Measurement in Science and Engineering · doi:10.1002/9781119244752.ch61 · Cited by 7
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Publisher
- Springer US
- Published
- 1971
- Cited by
- 1
- References
- 0
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review