The DOI matches its Crossref record.
Scanning Electron Microscopy and X-Ray Microanalysis
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644
Advances in water treatment by adsorption technology
Ali, I., & Gupta, V. K. (2006) · Nature Protocols · doi:10.1038/nprot.2006.370 · Cited by 1,525
Chemical Analysis of Microplastics and Nanoplastics: Challenges, Advanced Methods, and Perspectives
Ivleva, N. P. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00178 · Cited by 1,172
Counterfeit Integrated Circuits: A Rising Threat in the Global Semiconductor Supply Chain
Guin, U., Huang, K., DiMase, D., Carulli, J. M., Tehranipoor, M., & Makris, Y. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2332291 · Cited by 561
Alum interaction with dendritic cell membrane lipids is essential for its adjuvanticity
Flach, T. L., Ng, G., Hari, A., Desrosiers, M. D., Zhang, P., Ward, S. M., Seamone, M. E., Vilaysane, A., Mucsi, A. D., Fong, Y., et al. (2011) · Nature Medicine · doi:10.1038/nm.2306 · Cited by 405
Metadata
- Authors
- Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W. M., Scott, J. H. J., & Joy, D. C.
- Venue
- Springer eBooks
- Publisher
- Springer New York
- Published
- 2018
- OpenAlex
- W1504193762
- Cited by
- 5,361
- References
- 0
- FWCI
- 29.08
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scanning Electron Microscopy and X-Ray Microanalysis. https://app.cochat.ai/papers/10.1007/978-1-4939-6676-9
- The paper
- Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W. M., Scott, J. H. J., & Joy, D. C. (2018). Scanning Electron Microscopy and X-Ray Microanalysis. Springer eBooks. https://doi.org/10.1007/978-1-4939-6676-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.