The Lowry Method for Protein Quantitation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The most accurate method of determining protein concentration is probably acid hydrolysis followed by amino acid analysis. Most other methods are sensitive to the amino acid composition of the protein, and absolute concentrations cannot be obtained (1). The procedure of Lowry et al. (2) is no exception, but its sensitivity is moderately constant from protein to protein, and it has been so widely used that Lowry protein estimations are a completely acceptable alternative to a rigorous absolute determination in almost all circumstances in which protein mixtures or crude extracts are involved. The method is based on both the Biuret reaction, in which the peptide bonds of proteins react with copper under alkaline conditions to produce Cu + , which reacts with the Folin reagent, and the Folin—Ciocalteau reaction, which is poorly understood but in essence phosphomolybdotungstate is reduced to heteropoly-bdenum blue by the copper-catalyzed oxidation of aromatic amino acids. The reactions result in a strong blue color, which depends partly on the tyrosine and tryptophan content. The method is sensitive down to about 0.01 mg of protein/ mL, and is best used on solutions with concentrations in the range 0.01–1.0 mg/mL of protein. These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
[12] Determination of total protein
Peterson, G. L. (1983) · Methods in Enzymology · doi:10.1016/s0076-6879(83)91014-5 · Cited by 1,279
[16] Protein determination in membrane and lipoprotein samples: Manual and automated procedures
Markwell, M. A. K., Haas, S. M., Tolbert, N. E., & Bieber, L. L. (1981) · Methods in Enzymology · doi:10.1016/s0076-6879(81)72018-4 · Cited by 769
Artificial reductant enhancement of the Lowry method for protein determination
Larson, E., Howlett, B., & Jagendorf, A. (1986) · Analytical Biochemistry · doi:10.1016/0003-2697(86)90432-x · Cited by 331
A linear Lowry-Folin assay for both water-soluble and sodium dodecyl sulfate-solubilized proteins
Hess, H. H., Lees, M. B., & Derr, J. E. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90304-4 · Cited by 245
Cited by
Microalgae as Sources of High-Quality Protein for Human Food and Protein Supplements
Wang, Y., Tibbetts, S., & McGinn, P. (2021) · Foods · doi:10.3390/foods10123002 · Cited by 332
Loveday, S. M. (2019) · Annual Review of Food Science and Technology · doi:10.1146/annurev-food-032818-121128 · Cited by 296
Kazir, M., Abuhassira, Y., Robin, A., Nahor, O., Luo, J., Israel, A., Golberg, A., & Livney, Y. D. (2019) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2018.07.047 · Cited by 269
Jin, J., Okagu, O. D., Yagoub, A. E. A., & Udenigwe, C. C. (2021) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2020.105348 · Cited by 181
Spirulina platensis Protein as Sustainable Ingredient for Nutritional Food Products Development
Ramírez-Rodrigues, M. M., Estrada-Beristain, C., Metri-Ojeda, J., Pérez-Alva, A., & Baigts-Allende, D. K. (2021) · Sustainability · doi:10.3390/su13126849 · Cited by 125
Metadata
- Authors
- Waterborg, J. H.
- Venue
- Springer Protocols Handbooks
- Publisher
- Humana Press
- Published
- 2009
- Pages
- 7-10
- ISSN
- 1949-2448 (ISSN-L)
- 1949-2456
- OpenAlex
- W4231255226
- Cited by
- 278
- References
- 5
- FWCI
- 1.11
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Lowry Method for Protein Quantitation. https://app.cochat.ai/papers/10.1007/978-1-59745-198-7_2
- The paper
- Waterborg, J. H. (2009). The Lowry Method for Protein Quantitation. Springer Protocols Handbooks. https://doi.org/10.1007/978-1-59745-198-7_2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.