The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Optical Coherence Tomography (OCT): Principle and Technical Realization
Open accessAbstract
Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional tissue imaging. It typically uses light in the near-infrared spectral range which has a penetration depth of several hundred microns in tissue. The backscattered light is measured with an interferometric set-up to reconstruct the depth profile of the sample at the selected location. A scanning OCT beam allows for acquisition of cross-sectional images of the tissue structure. Different technical methods are introduced and compared regarding their properties like sensitivity, imaging speed and penetration depth. Regardless of the technical realization, axial resolution and imaging range of an OCT system are determined by light source and detector characteristics. Combining retinal OCT with a confocal scanning laser ophthalmoscope allows for motion tracking during acquisition and to examine the exact same position at any time again. Segmentation of features is the basis for automatic depth measurements and standardized measurements to be compared with normative databases. New trends show the ability of functional OCT to image flow, polarizing properties of tissue and even mechanical properties like elasticity. Recent approaches to improve the resolution and the acquisition speed show the ongoing research interest in OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“OCT imaging at depth is negatively affected by absorption with light absorption and attenuation in upper tissue layers leading to less light reaching lower layers.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K. W., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 14,001
Optical coherence tomography - principles and applications
FERCHER, A. F., Drexler, W., Hitzenberger, C. K. F., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,871
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R. A., Hitzenberger, C. K. F., & FERCHER, A. F. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,859
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M. A., Šarunic, M. V., Yang, C., & Izatt, J. A. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,789
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,245
Measurement of intraocular distances by backscattering spectral interferometry
FERCHER, A. F., Hitzenberger, C. K. F., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,208
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,036
Huber, R. A., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Refractive indices of water and ice in the 065- to 25-μm spectral range
Kou, L., Labrie, D., & Chýlek, P. (1993) · Applied Optics · doi:10.1364/ao.32.003531 · Cited by 804
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Cited by
Sorted by citations
Wave-based optical coherence elastography: the 10-year perspective
Zvietcovich, F., & Larin, K. V. (2021) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac4512 · Cited by 127
Anatomical structures, cell types and biomarkers of the Human Reference Atlas
Börner, K., Teichmann, S. A., Quardokus, E. M., Gee, J. C., Browne, K., Osumi-Sutherland, D., Herr, B. W., Bueckle, A., Paul, H., Haniffa, M. A., et al. (2021) · Nature Cell Biology · doi:10.1038/s41556-021-00788-6 · Cited by 123
Towards a better understanding of annotation tools for medical imaging: a survey
Aljabri, M., Alamir, M., Alghamdi, M., Abdel-Mottaleb, M. S., & Collado‐Mesa, F. (2022) · Multimedia Tools and Applications · doi:10.1007/s11042-022-12100-1 · Cited by 111
Oculomics: Current concepts and evidence
Zhu, Z., Wang, Y., Qi, Z., Hu, W., Zhang, X., Wagner, S. K., Wang, Y., Ran, A. R., Ong, J., Waisberg, E., et al. (2025) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2025.101350 · Cited by 97
Imaging of Uveal Melanoma—Current Standard and Methods in Development
Solnik, M., Paduszyńska, N., Czarnecka, A. M., Synoradzki, K. J., Yousef, Y. A., Chorągiewicz, T., Ręjdak, R., Toro, M. D., Zweifel, S. A., Dyndor, K., et al. (2022) · Cancers · doi:10.3390/cancers14133147 · Cited by 92
Metadata
- Authors
- Aumann, S., Donner, S., Fischer, J., & Müller, F.
- Affiliations
- Heidelberg Engineering (Germany) (DE)
- Venue
- High Resolution Imaging in Microscopy and Ophthalmology
- Publisher
- Springer International Publishing
- Published
- 2019
- Pages
- 59-85
- OpenAlex
- W2967073593
- Cited by
- 449
- References
- 46
- Citations by year
- 2026: 41 · 2025: 112 · 2024: 109 · 2023: 71 · 2022: 70 · 2021: 31 · 2020: 15
- FWCI
- 44.32
- Type
- book chapter
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Springer eBooks (publishedVersion, cc-by)
- Funders
- Heidelberg Engineering GmbH
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Adaptive optics and wavefront sensing
- Keywords
- optical coherence tomography, retinal imaging, near-infrared light, interferometry, axial resolution, penetration depth, confocal scanning laser ophthalmoscope, motion tracking, image segmentation, depth measurement, tissue elasticity imaging, imaging speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review