Cited by 3Neuroscience and Neural EngineeringMuscle activation and electromyography studiesVagus Nerve Stimulation Research

Peripheral Nerve Electrodes

Wu, Yu, Guo, Liang·2020·Neural Interface Engineering

Integrity signals

Registry

Crossref · 10.1007/978-3-030-41854-0_5

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Closer proximity of the electrode to the target axons facilitates increased selective stimulation in the peripheral nerves.

    “Closer proximity of the electrode to the target axons facilitates increased selective stimulation in the peripheral nerves [27, 28].”

The citation lists haven’t been fetched yet

References 114 · Cited by 3

Authors
Wu, Y., & Guo, L.
Affiliations
The Ohio State University (US)
Corresponding author
Guo, Liang
Venue
Neural Interface Engineering
Published
2020
Pages
95-121
OpenAlex
W3022698350
Cited by
3
References
114
Citations by year
2024: 1 · 2023: 1 · 2021: 1
FWCI
1.10
Type
book chapter
Language
en
Open access
closed
Locations
Springer eBooks (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
electrode design, neural recording, neurostimulation, peripheral nerve interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review