Cited by 12Medical Image Segmentation TechniquesBrain Tumor Detection and ClassificationAdvanced Neural Network Applications

PRISM: A Promptable and Robust Interactive Segmentation Model with Visual Prompts

Open access
Li, Hao, Liu, Han, Hu, Dewei, Wang, Jiacheng, Oguz, Ipek·2024·Lecture Notes in Computer Science

Abstract

In this paper, we present PRISM, a P romptable and R obust I nteractive S egmentation M odel, aiming for precise segmentation of 3D medical images. PRISM accepts various visual inputs, including points, boxes, and scribbles as sparse prompts, as well as masks as dense prompts. Specifically, PRISM is designed with four principles to achieve robustness: (1) Iterative learning. The model produces segmentations by using visual prompts from previous iterations to achieve progressive improvement. (2) Confidence learning. PRISM employs multiple segmentation heads per input image, each generating a continuous map and a confidence score to optimize predictions. (3) Corrective learning. Following each segmentation iteration, PRISM employs a shallow corrective refinement network to reassign mislabeled voxels. (4) Hybrid design. PRISM integrates hybrid encoders to better capture both the local and global information. Comprehensive validation of PRISM is conducted using four public datasets for tumor segmentation in the colon, pancreas, liver, and kidney, highlighting challenges caused by anatomical variations and ambiguous boundaries in accurate tumor identification. Compared to state-of-the-art methods, both with and without prompt engineering, PRISM significantly improves performance, achieving results that are close to human levels. The code is publicly available at https://github.com/MedICL-VU/PRISM.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/978-3-031-72384-1_37

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • To make the comparison with PRISM controlled, we use the released PRISM data splits without resampling the train/test partition, resulting in 26 test cases for MSD-Colon and 61 test cases for KiTS21.

    “To make the comparison with PRISM [16] controlled, we use the released PRISM data splits without resampling the train/test partition, resulting in 26 test cases for MSD-Colon and 61 test cases for KiTS21.”

    From Correction-aware interactive 3D tumor segmentation with sparse and revisable prompts (2026) · cites this paper as [16]

    The Experiments > Datasets passage says PRISM used colon and kidney datasets with 126 and 300 cases, respectively, and adopted a 70/10/20 training/validation/testing split from a prior study. It does not give the exact test counts of 26 and 61 or state that those partitions were released; the citing authors’ decision not to resample is their own procedure. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • PRISM combines clicks, 3D bounding boxes, and scribbles with an iterative refinement head, making it a closely matched baseline for interactive 3D tumor segmentation.

    “PRISM [16] combines clicks, 3D bounding boxes, and scribbles with an iterative refinement head, making it a closely matched baseline for interactive 3D tumor segmentation.”
  • If a voxel is labeled as foreground in one round and background in a later round, PRISM's two-map refinement input can activate both positive and negative prompt channels at that location.

    “If a voxel is labeled as foreground in one round and background in a later round, PRISM's two-map refinement input can activate both positive and negative prompt channels at that location.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

2 of the 32 references couldn’t be matched to a known paper.

Research works printed but not linked: 6

  1. [4]Chen X, Cheung YSJ, Lim SN, Zhao H: Scribbleseg: Scribble-based interactive image segmentation. arXiv preprint arXiv:2303.11320 (2023) · arXiv
  2. [5]Cheng J, Ye J, Deng Z, Chen J, Li T, Wang H, Su Y, Huang Z, Chen J, Jiang L,: Sam-med2d. arXiv preprint arXiv:2308.16184 (2023) · arXiv
  3. [15]Lee HH, Bao S, Huo Y, Landman BA: 3d UX-net: A large kernel volumetric convnet modernizing hierarchical transformer for medical image segmentation. In: The Eleventh International Conference on Learning Representations (2023) PMC13597054 42775365
  4. [31]Wang H, Guo S, Ye J, Deng Z, Cheng J, Li T, Chen J, Su Y, Huang Z, Shen Y,: Sam-med3d. arXiv preprint arXiv:2310.15161 (2023) · arXiv
  5. [34]Yao X, Liu H, Hu D, Lu D, Lou A, Li H, Deng R, Arenas G, Oguz B, Schwartz N,: False negative/positive control for sam on noisy medical images. arXiv preprint (2023) PMC11182739 38894708
  6. [35]Zhang Y, Hu S, Jiang C, Cheng Y, Qi Y: Segment anything model with uncertainty rectification for auto-prompting medical image segmentation. arXiv preprint arXiv:2311.10529 (2023) · arXiv

Cited by

Sorted by citations

Authors
Li, H., Liu, H., Hu, D., Wang, J., & Oguz, I.
Affiliations
Vanderbilt University (US)
Venue
Lecture Notes in Computer Science
Published
2024
Volume
15003
Pages
389-399
ISSN
  • 0302-9743 (ISSN-L)
  • 1611-3349
OpenAlex
W4403071691
Cited by
12
References
32
Citations by year
2026: 3 · 2025: 7 · 2024: 2
FWCI
2.48
Type
conference paper
Language
en
Open access
Locations
  • Lecture notes in computer science (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • arXiv (Cornell University) (submittedVersion, cc-by)
  • arXiv (Cornell University) (cc-by)
Funders
  • National Science Foundation (2220401)
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke (U01NS106845)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD109739)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Life Sciences › Neuroscience › Neurology › Brain Tumor Detection and Classification
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
Keywords
interactive segmentation, 3D medical image segmentation, visual prompts, point prompts, iterative learning, hybrid encoder, tumor segmentation, colon, pancreas, liver, kidney, prompt engineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review