The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Faults and Diagnosis Systems in Power Converters
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“About 30% of FC failures are related to abnormal operation of intermediate filter capacitors.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [240]
In the citing paper
“As a result of aging their capacity decreases and the internal impedance increases [240].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [240]
In the citing paper
“The lifetime of the capacitor is considered to be reached when the ESR of the capacitor increases more than twice the initial value [240].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [240]
In the citing paper
“There are many fault types of in power converters such as a power semiconductor device (21%), solder (13%), DC-link capacitors (30%), printed circuit boards (PCB) (26%), sensors, etc. [240].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [240]
In the citing paper
“They account for 12% of all failures related to electric drives [240].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [240]
Citations
Cites
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A. T., Mawby, P., Xiang, D., Ran, L., & Tavner, P. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,058
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · Conference record · doi:10.1109/ias.1997.629048 · Cited by 304
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Śleszyński, W., NIEZNAŃSKI, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodriguez, M. A., Claudio, A., Theilliol, D., Valdés, L. G. V., Sibaja-Terán, P., Hernández-González, L., & Aguayo, J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 266
An, Q., Sun, L., Zhao, K., & Sun, L. Z. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U., Jeong, H.-G., Lee, K., & Blaabjerg, F. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 244
Self-citationPu, X.-S., Nguyen, T. H., Lee, D., et al. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2218561 · Cited by 189
A Simple Offline Technique for Evaluating the Condition of Aluminum–Electrolytic–Capacitors
Amaral, A. M. R., & Cardoso, A. J. M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2022077 · Cited by 150
A New Fault Detection Technique for IGBT Based on Gate Voltage Monitoring
Rodriguez, M. A., Claudio, A., Theilliol, D., & Vela, L. G. (2007) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2007.4342127 · Cited by 107
IGBT Fault Protection Based on di/dt Feedback Control
Huang, F. H., & Flett, F. (2007) · PESC record · doi:10.1109/pesc.2007.4342213 · Cited by 100
Trabelsi, M., Boussak, M., & Gossa, M. (2010) · doi:10.1109/icelmach.2010.5608044 · Cited by 94
Fault diagnosis of three-parallel voltage-source converter for a high-power wind turbine
Ko, Y., Lee, K., Lee, D., et al. (2012) · IET Power Electronics · doi:10.1049/iet-pel.2011.0109 · Cited by 84
Self-citationA Novel Fault Detection Scheme for Voltage Fed PWM Inverter
Yu, O.-S., Park, N.-J., & Hyun, D.-S. (2006) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2006.347541 · Cited by 69
Switching voltage transient protection schemes for high-current IGBT modules
Chokhawala, R., & Sobhani, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.649974 · Cited by 55
Ko, Y., & Lee, K. (2010) · Journal of Power Electronics · doi:10.6113/jpe.2010.10.6.686 · Cited by 53
Self-citationA novel fault detection circuit for short-circuit faults of IGBT
Kim, M.-S., Park, B.-G., Kim, R.-Y., et al. (2011) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2011.5744621 · Cited by 31
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Diagnostic symptom Method [240], [241] ESR calculation on-line AC current injection (in q axis) Indirect DC-link capacitor current estimation Direct measurement of DC-link and capacitor voltage ESR estimation with RLS method [242], [240] ESR calculation off-line Capacitor model Hardware measurement In the case of algo…”
BackgroundMethodInfluentialFault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Metadata
- Authors
- Lee, K.-B., & Choi, U.-M.
- Affiliations
- Ajou University (KR)
- Aalborg University (DK)
- Corresponding author
- Choi, Ui-Min
- Venue
- Studies in Computational Intelligence
- Publisher
- Springer International Publishing
- Published
- 2014
- Pages
- 143-178
- ISSN
- 1860-949X (ISSN-L)
- 1860-9503
- OpenAlex
- W181617720
- Cited by
- 6
- References
- 19
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 3 · 2016: 1
- FWCI
- 1.16
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- Locations
- Studies in computational intelligence (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical Fault Detection and Protection
- Keywords
- power converter faults, fault diagnosis, open-circuit fault, short-circuit faults, condition monitoring, power electronics reliability, renewable energy systems, motor drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review