Magnetometry with Nitrogen-Vacancy Centers in Diamond
The DOI matches its Crossref record; 82 of the 83 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology
Schirhagl, R., Chang, K., Loretz, M., & Degen, C. L. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103659 · Cited by 1,608
Magnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Electric-field sensing using single diamond spins
Dolde, F., Fedder, H., Doherty, M. W., Nöbauer, T., Rempp, F., Balasubramanian, G., Wolf, T., Reinhard, F., Hollenberg, L. C. L., Jelezko, F., et al. (2011) · Nature Physics · doi:10.1038/nphys1969 · Cited by 1,334
3 The nitrogen-vacancy colour centre in diamondPreprint
Doherty, M. W., Manson, B. N. B., Delaney, B. P., Jelezko, F., Wrachtrupe, D. J., & Hollenberg, L. C. L. (2013) · Cited by 1,312
Zaitsev, A. M. (2001) · Springer eBooks · doi:10.1007/978-3-662-04548-0 · Cited by 1,120
Solid-state electronic spin coherence time approaching one second
Bar-Gill, N., Pham, L. M., Jarmola, A., Budker, D., & Walsworth, R. L. (2013) · Nature Communications · doi:10.1038/ncomms2771 · Cited by 799
Self-citationNuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume
Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J. (2013) · Science · doi:10.1126/science.1231675 · Cited by 754
Nanoscale Nuclear Magnetic Resonance with a Nitrogen-Vacancy Spin Sensor
Mamin, H. J., Kim, M., Sherwood, M. H., Rettner, C. T., Ohno, K., Awschalom, D. D., & Rugar, D. (2013) · Science · doi:10.1126/science.1231540 · Cited by 752
Cited by
Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond
Casola, F., van der Sar, T., & Yacoby, A. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.88 · Cited by 635
Spin Hyperpolarization in Modern Magnetic Resonance
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00534 · Cited by 368
Self-citationHow to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
“Note that optically pumped magnetometers based on nitrogen-vacancy (NV) centers in diamond [12] are not included in this table, since commercial NV sensors at the time of writing are sold only as scanning-microscopy imaging systems.”
BackgroundImaging crystal stress in diamond using ensembles of nitrogen-vacancy centers
Kehayias, P., Turner, M. J., Trubko, R., Schloss, J. M., Hart, C., Wesson, M. E., Glenn, D. R., & Walsworth, R. L. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.100.174103 · Cited by 105
“C is the fluorescence contrast and is the resonance linewidth [34].”
BackgroundSelf-citationZero-Field Magnetometry Based on Nitrogen-Vacancy Ensembles in Diamond
Zheng, H., Xu, J., Iwata, G. Z., Lenz, T., Michl, J., Yavkin, B. V., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., et al. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.064068 · Cited by 96
“[26] K.”
BackgroundSelf-citation
Metadata
- Authors
- Jensen, K., Kehayias, P., & Budker, D.
- Affiliations
- University of Copenhagen (DK)
- Center for Astrophysics Harvard & Smithsonian (US)
- Johannes Gutenberg University Mainz (DE)
- Corresponding author
- Jensen, Kasper
- Venue
- Smart Sensors, Measurement and Instrumentation
- Publisher
- Springer International Publishing
- Published
- 2016-09-21
- Pages
- 553-576
- ISSN
- 2194-8402 (ISSN-L)
- 2194-8410
- OpenAlex
- W2521629684
- Cited by
- 38
- References
- 83
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 1 · 2023: 7 · 2022: 2 · 2021: 2 · 2020: 6 · 2019: 6 · 2018: 6 · 2017: 1
- FWCI
- 11.69
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Smart sensors, measurement and instrumentation (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- GSI Repository (German Federal Government) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- nitrogen-vacancy centers, diamond, optically detected magnetic resonance, magnetic field sensing, quantum sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetometry with Nitrogen-Vacancy Centers in Diamond. https://app.cochat.ai/papers/10.1007/978-3-319-34070-8_18
- The paper
- Jensen, K., Kehayias, P., & Budker, D. (2017). Magnetometry with Nitrogen-Vacancy Centers in Diamond. Smart Sensors, Measurement and Instrumentation. https://doi.org/10.1007/978-3-319-34070-8_18
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.