The DOI matches its Crossref record.
Nuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume
Abstract
Nanoscale NMR with Diamond Defects: Although nuclear magnetic resonance (NMR) methods can be used for spatial imaging, the low sensitivity of detectors limits the minimum sample size. Two reports now describe the use of near-surface nitrogen-vacancy (NV) defects in diamond for detecting nanotesla magnetic fields from very small volumes of material (see the Perspective by Hemmer ). The spin of the defect can be detected by changes in its fluorescence, which allows proton NMR of organic samples only a few nanometers thick on the diamond surface. Mamin et al. (p. 557 ) used a combination of electron spin echoes and pulsed NMR manipulation of the proton spins to detect the very weak fields. Staudacher et al. (p. 561 ) measured statistical polarization of a population of about 10 4 spins near the NV center with a dynamical decoupling method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Self-citationSingle-protein spin resonance spectroscopy under ambient conditions
Shi, F., Zhang, Q., Wang, P., Sun, H., Wang, J., Rong, X., Chen, M., Ju, C., Reinhard, F., Chen, H., et al. (2015) · Science · doi:10.1126/science.aaa2253 · Cited by 406
Self-citationSubmillihertz magnetic spectroscopy performed with a nanoscale quantum sensor
Schmitt, S., Gefen, T., Stürner, F. M., Unden, T., Wolff, G., Müller, C., Scheuer, J., Naydenov, B., Markham, M., Pezzagna, S., et al. (2017) · Science · doi:10.1126/science.aam5532 · Cited by 359
Self-citationHigh-fidelity spin entanglement using optimal control
Dolde, F., Bergholm, V., Wang, Y., Jakobi, I., Naydenov, B., Pezzagna, S., Meijer, J., Jelezko, F., Neumann, P., Schulte-Herbrüggen, T., et al. (2014) · Nature Communications · doi:10.1038/ncomms4371 · Cited by 325
Self-citationTime-resolved magnetic sensing with electronic spins in diamond
Cooper, A., Magesan, E., Yum, H. N., & Cappellaro, P. (2014) · Nature Communications · doi:10.1038/ncomms4141 · Cited by 73
Metadata
- Authors
- Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J.
- Venue
- Science
- Published
- 2013-02
- Volume
- 339
- Issue
- 6119
- Pages
- 561-563
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2055855286
- Cited by
- 754
- References
- 0
- FWCI
- 36.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume. https://app.cochat.ai/papers/10.1126/science.1231675
- The paper
- Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J. (2013). Nuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume. Science. https://doi.org/10.1126/science.1231675
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.