Cited by 184Diabetes Management and ResearchAdvanced Control Systems OptimizationPancreatic function and diabetes

Closed-Loop Control of Blood Glucose

F. Chee, Tyrone Lucius Fernando·2007·Lecture Notes in Control and Information Sciences

Integrity signals

Registry

Crossref · 10.1007/978-3-540-74031-5

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Sorensen model was formulated to simulate the behaviour of both normal and diabetic individuals.

    “While the Hovorka model and the UVAPadova Simulator only describe the glucose metabolism of a subject with type 1 diabetes, the Sorensen model was formulated to simulate the behaviour of both normal and diabetic individuals.”
  • The Sorensen model is the most complete of the three models.

    “The Sorensen model is the most complete, even though some modifications were required both to the model equations (adding useful compartments for modelling subcutaneous insulin delivery) and to the parameter values.”

Cited by

Sorted by citations

Authors
Chee, F., & Fernando, T. L.
Venue
Lecture Notes in Control and Information Sciences
Published
2007
OpenAlex
W1512968617
Cited by
184
References
0
Citations by year
2024: 3 · 2023: 5 · 2022: 2 · 2021: 11 · 2020: 7 · 2019: 12 · 2018: 14 · 2017: 13 · 2016: 11 · 2015: 15 · 2014: 14 · 2013: 18 · 2012: 13
FWCI
9.08
Type
book
Language
en
Open access
closed
Locations
  • Springer eBooks (publishedVersion)
  • UWA Profiles and Research Repository (University of Western Australia) (submittedVersion)
  • CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
  • DIAL (Catholic University of Leuven) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
feedback control, blood glucose regulation, diabetes management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review