Assessment of Chemical Hazards in Sick Building Syndrome Situations: Determination of Concentrations and Origin of VOCs in Indoor Air Environments by Dynamic Sampling and TD-GC/MS Analysis
The DOI matches its Crossref record; 158 of the 159 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In offices in California, levels of individual VOCs ranged from non-detect to over 1000 μg/m3 [48, 49].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [48]
Citations
Cites
2 retracted
Materials Emission of Chemicals - PVC Flooring Materials
Lundgren, B., Jonsson, B. G., & Ek-Olausson, B. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00007.x · Cited by 54
RetractedThe sex ratio of offspring sired by men exposed to wood preservatives contaminated by dioxin
James, W. H. (1997) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.182 · Cited by 15
RetractedAtmospheric chemistry of VOCs and NOx
Atkinson, R. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00460-4 · Cited by 3,500
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Adsorption — from theory to practice
Dąbrowski, A. (2001) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(00)00082-8 · Cited by 2,375
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Prüss‐Üstün, A., & Corvalán, C. (2006) · DigitalGeorgetown (Georgetown University Library) · Cited by 930
Atmospheric composition change – global and regional air quality
Monks, P. S., Granier, C., Fuzzi, S., Stohl, A., Williams, M. L., Akimoto, H., Amann, M., Baklanov, A., Baltensperger, U., Bey, I., et al. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.08.021 · Cited by 872
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Research works printed but not linked: 20
- EC (European Commission) (1992) Ventilation Requirements in Buildings. Indoor air quality & its impact on man (Report No. 11). Office for Official Publication of the European Communities, Luxembourg.
- EC (European Commission) (1997a) Total Volatile Organic Compounds (TVOC) in Indoor Air Quality Investigations. Indoor air quality & its impact on man (Report No. 19). Office for Official Publication of the European Communities, Luxembourg.
- EC (European Commission) (1997b) Evaluation of VOC Emissions from Building Products. Indoor air quality & its impact on man (Report No. 18). Office for Official Publication of the European Communities, Luxembourg.
- Gallego E, Roca FJ, Perales JF, Guardino X (2008a) Simultaneous evaluation of odor episodes and air quality: Methodology to identify air pollutants and their origin combining chemical analysis (TD-GC/MS), social participation, and mathematical simulations techniques. In: Romano GC, Conti AG (Eds.) Air Quality in the XXI Century. Nova Science Publishers Inc., New York, NY.
- Godish T (1997) Air Quality. Lewis Publishers, CRC Press, Boca Raton, FL.
- Griman JR, Hadwen GE, Burton LE, Wombe SE, McCarthy JF (1999) Individual volatile organic compound prevalence and concentrations in 56 buildings of the building assessment survey and evaluation (BASE) study. In: Proceedings of the 8th international conference on indoor air quality and climate, vol. 2, pp. 460–465, Edinburgh, Scotland.
- Hummel T, Dalton P, Dilks DD (1999) Effects of exposure to irritants. Soc Neurosci Abstr 25:2187.
- Krause C, Mailahn W, Nagel R, Schulz C, Seifert B, Ullrich D (1987) Occurrence of volatile organic compounds in the air of 500 homes in the Federal Republic of Germany. In: Proceedings of indoor air’87, institute of water, soil and air hygiene, Berlin-Dahlem, Germany.
- McKenzie JR, Mann J (2004) Use of odour annoyance index surveys for the confirmation of computer based dispersion modelling. Proceedings of Air Quality Modelling Conference: Air Quality Modelling. Air & Waste Management Association, pp.285–299.
- Repetto M (1997) Toxicología Fundamental. Ediciones Díaz Santos, S.A. Madrid, Spain.
- Roca FJ (2006) Disseny d’un sistema de control d’olors i de la qualitat de l’aire. Caracterització, quantificació i assignació de l’origen dels compostos orgànics volàtils. Thesis, Department of Mining Engineering and Natural Resources, Polytechnic University of Catalonia. Barcelona, Spain.
- Roca FJ, Ribes A, Perales JF, Carrera G (2005) Projecte de caracterització d’episodis d’olor i de la qualitat de l’aire a les zones d’impacte de l’àrea urbana de Banyoles. Laboratori del Centre de Medi Ambient, Polytechnic University of Catalonia, Barcelona.
- Seltzer JM (1995) Sources, concentrations, and assessment of indoor pollution. In: Seltzer JM (Ed.) Occupational Medicine: Effects of the Indoor Environment on Health. Hanley and Belfus, Philadelphia, PA.
- US EPA (1999) Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, Method TO-15 (EPA/625/R-96/010b). Center for Environmental Research Information, Office of Research and Development, Cincinnati, OH.
- WHO (World Health Organisation) (1982) Indoor Air Pollutants, Exposure and Health Effect Assessments (Euro Reports and Studies No. 78). WHO regional office for Europe, Copenhagen.
- WHO (World Health Organisation) (1986) Indoor Air Quality Research: Report on a WHO Meeting (Euro Reports and Studies No. 103). WHO, Regional Office for Europe, Copenhagen.
- WHO (World Health Organisation) (1989) Indoor Air Quality: Organic Pollutants (Euro Reports and Studies No. 111). WHO Regional Office for Europe, Copenhagen.
- WHO (World Health Organisation) (2002) Reducing Risks, Promoting Healthy Life. The World Health Report 2002, Geneva.
- WHO (World Health Organization) (2005) WHO Air Quality Guidelines: Global Update. WHO Regional Office for Europe, Copenhagen.
- WHO (World Health Organisation) (2006) Fuel for Life: Household Energy and Health. WHO, Geneva.
Cited by
Gallego, E., Roca, F. J., Lorente, J. F. P., Sánchez, G. L., & Esplugas, P. (2012) · Waste Management · doi:10.1016/j.wasman.2012.07.010 · Cited by 131
Self-citationGallego, E., Roca, F. J., Lorente, J. F. P., & Guardino, X. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.05.003 · Cited by 110
Self-citationLin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
Teiri, H., Hajizadeh, Y., & Azhdarpoor, A. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01118-3 · Cited by 44
Ulpiani, G., Nazarian, N., Zhang, F., & Pettit, C. J. (2021) · Frontiers in Environmental Science · doi:10.3389/fenvs.2021.725974 · Cited by 24
Metadata
- Authors
- Gallego, E., Roca, F. J., Perales, J. F., & Guardino, X.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- Instituto Nacional de Seguridad y Salud en el Trabajo (ES)
- Corresponding author
- Gallego, Eva
- ORCID
- Gallego, Eva
- Venue
- Sick Building Syndrome
- Publisher
- Springer Berlin Heidelberg
- Published
- 2011
- Pages
- 289-333
- OpenAlex
- W2138323395
- Cited by
- 9
- References
- 159
- Citations by year
- 2021: 2 · 2020: 2 · 2019: 2 · 2013: 1 · 2012: 2
- FWCI
- 1.94
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Springer eBooks (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemical Engineering › Process Chemistry and Technology › Odor and Emission Control Technologies
- Keywords
- sick building syndrome, volatile organic compounds, indoor air quality, chemical hazards, dynamic sampling, capillary gas chromatography-mass spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Chemical Hazards in Sick Building Syndrome Situations: Determination of Concentrations and Origin of VOCs in Indoor Air Environments by Dynamic Sampling and TD-GC/MS Analysis. https://app.cochat.ai/papers/10.1007/978-3-642-17919-8_16
- The paper
- Gallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011). Assessment of Chemical Hazards in Sick Building Syndrome Situations: Determination of Concentrations and Origin of VOCs in Indoor Air Environments by Dynamic Sampling and TD-GC/MS Analysis. Sick Building Syndrome. https://doi.org/10.1007/978-3-642-17919-8_16
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.