Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks
Open accessAbstract
Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce. Little is known about their exposure to chemicals, including volatile organic compounds (VOCs). This study evaluates VOC exposures of housekeepers, sources and factors affecting VOC levels, and provides preliminary estimates of VOC-related health risks. We utilized indoor and personal sampling at two hotels, assessed ventilation, and characterized the VOC composition of cleaning agents. Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 µg/m3 (mean ± SD), about twice that of indoor samples. VOCs of greatest health significance included chloroform and formaldehyde. Several workers had exposure to alkanes that could cause non-cancer effects. VOC levels were negatively correlated with estimated air change rates. The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection by-products in the laundry room, and cleaning products. VOC levels and the derived health risks in this study were at the lower range found in the US buildings. The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
15 of 103 cited sources checked · 7 supported · 0 flagged · accuracy not yet measured
- Premisecitation
Epidemiological studies suggest that cleaning product exposure may be linked to the onset or worsening of respiratory symptoms and asthma.
“Epidemiological studies suggest that exposure to cleaning products can be associated with the development and/or exacerbation of respiratory symptoms and asthma [15–18].”
Quote in the paperSubstantial claim4 of 4 sources checked- cites [15] source
- cites [16] source
The Abstract reports increased incidence of adult-onset asthma among Finnish female cleaners, and the Discussion suggests that differences in cleaning agents may partly explain the risk. The study did not establish an association with exposure to specific cleaning products or examine exacerbation of existing asthma or respiratory symptoms. Page numbers are unavailable in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [17] source
The 'Characteristics of reporting physicians' section (Fig. 2; page not provided) includes cleaners among occupations with reported occupational asthma, supporting a possible occupational link. But the paper does not establish that cleaning products specifically caused those cases or address exacerbation of existing asthma; its 'Suspected agents and occupations' section says the occupation–agent details are not presented. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [18] source
- Premisecitation
Some VOCs in cleaning products are known or suspected to cause health effects such as eye, skin, and respiratory irritation; liver and kidney damage; reproductive effects; and cancer.
“Several of these compounds have known or suspected adverse health effects, e.g., irritation to eyes, skin and the respiratory system; damage to the liver and kidney; reproductive effects; and carcinogenicity [11, 12].”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [11] source
- cites [12] source
The ‘Sensory irritants formed during terpene oxidation reactions’ section links cleaning products with irritation symptoms and says reactions involving certain VOCs produce sensory irritants. The ‘Measurements of organic compounds in the indoor environment’ section also recognizes organic compounds with toxic properties, but our copy does not substantiate the attributed skin irritation, liver or kidney damage, reproductive effects, or carcinogenicity for VOCs in cleaning products. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
Personal samples are generally considered more representative of occupational exposure than indoor samples.
“Personal samples are generally considered to be more representative of occupational exposure than indoor samples [25].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [25] source
- Premisecitation
Terpenes such as limonene and α-pinene are abundant in laundry and cleaning products.
“Terpenes, e.g., limonene, α-pinene are abundant in laundry and cleaning products [21, 73–75].”
Quote in the paperNot a substantial claim2 of 4 sources checked- cites [21] source
- cites [73] source
Section 1.3 identifies limonene and α-pinene as terpenes and reports that both were among the most common VOCs emitted by air fresheners in a US study. It does not establish that they are abundant in laundry or cleaning products; those are different product categories. The indexed passages provide no page number. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [74] source
Section 3.1 (Product composition) reports terpenoids in a pine-oil cleaner, and the composition table lists both α-pinene and d-limonene. The paper supports their presence in a cleaning product, but the passages do not address laundry products or establish that these compounds are abundant across both product categories. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [75] source
- Findingown data
The average excess lifetime cancer risk estimate was 4.1 × 10−5.
“The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.”
Quote in the paperSubstantial claim- The authors state this as an assumption: The risk calculations assume a 40-hour work week.
- Findingown data
The study detected 35 of 98 target VOCs in the hotels, spanning aromatics, halohydrocarbons, esters, ketones, aldehydes, alkanes, and terpenes.
“We detected 35 of the 98 target VOCs in the hotels, including aromatics, halohydrocarbons, esters, ketones, aldehydes, alkanes, and terpenes (Table S1).”
Quote in the paperNot a substantial claim - Findingown data
In winter, the laundry worker's hexanal concentration was lower than room cleaners' (1.7 vs 2.7 ± 0.9 μg/m3).
“Also in winter, hexanal concentrations of the laundry worker were lower than room cleaners (1.7 μg/m3 versus 2.7 ± 0.9 μg/m3).”
Quote in the paperNot a substantial claim - Findingown data
Halohydrocarbons were detected in most personal samples, except those from maintenance workers.
“Halohydrocarbons were found in most of the personal samples (except the maintenance workers).”
Quote in the paperNot a substantial claim - Findingown data
Personal sampling of hotel staff found a total target VOC concentration of 57 ± 36 μg/m3, roughly double the indoor level.
“Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 μg/m3 (mean ± standard deviation), about twice that of indoor samples.”
- Also stated in: § VOC levels in outdoor, indoor and personal samples · plain
“For the personal samples, TTVOC levels averaged 57 ± 36 μg/m3, nearly twice the indoor measurements (p = 0.008).”
Quote in the paperSubstantial claim - Also stated in: § VOC levels in outdoor, indoor and personal samples · plain
- Findingown data
Among the target VOCs, alkanes frequently had the highest concentrations.
“Among the target VOCs, alkanes often had the highest concentrations.”
Quote in the paperNot a substantial claim - Findingown data
Maintenance workers had higher personal n-undecane concentrations than other workers (8.3 vs 0.1 μg/m3, p = 0.09).
“Maintenance workers had higher personal concentrations of n-nonane (24 μg/m3) and n-undecane (8.3 μg/m3) than other workers (0.5 μg/m3, 0.1 μg/m3 respectively, p = 0.09), possibly reflecting use of lubricants.”
Quote in the paperNot a substantial claim - Findingown data
Office workers had higher personal n-tetradecane concentrations than housekeepers (7.2 ± 4.1 vs 2.0 ± 3.8 μg/m3, p = 0.01).
“Office workers, who frequented the break room, also had higher personal measurements of n-tetradecane than the housekeepers (7.2 ± 4.1 μg/m3 versus 2.0 ± 3.8 μg/m3, p = 0.01).”
Quote in the paperNot a substantial claim - Findingown data
Maintenance workers had higher personal n-nonane concentrations than other workers (24 vs 0.5 μg/m3, p = 0.09).
“Maintenance workers had higher personal concentrations of n-nonane (24 μg/m3) and n-undecane (8.3 μg/m3) than other workers (0.5 μg/m3, 0.1 μg/m3 respectively, p = 0.09), possibly reflecting use of lubricants.”
Quote in the paperNot a substantial claim - Findingown data
Carbon tetrachloride was detected in only one room cleaner sample, at 2.0 μg/m3.
“Carbon tetrachloride was found only in one room cleaner sample, 2.0 μg/m3 (the global background level is 0.6 μg/m3, below the MDL of 1.0 μg/m3 in present study).”
Quote in the paperNot a substantial claim - Findingown data
Laundry workers' personal BTEX concentrations (8.2 ± 1.4 μg/m3) exceeded those of other workers (3.4 ± 2.1 μg/m3; p = 0.02).
“Laundry workers also had personal measurements of BTEX compounds (8.2 ± 1.4 μg/m3) that exceeded those of other workers (3.4 ± 2.1 μg/m3; p = 0.02).”
Quote in the paperNot a substantial claim - Findingown data
Aromatic VOC concentrations were lower in the lobby than at other indoor sites (0.9 ± 0.3 vs 3.9 ± 3.2 μg/m3, p = 0.07).
“Aromatic VOCs had lower levels in the lobby than other indoor sites (0.9 ± 0.3 μg/m3 versus 3.9 ± 3.2 μg/m3, p = 0.07), and laundry workers had the highest personal measurements among hotel workers (8.6 ± 0.8 μg/m3 versus 3.7 ± 2.3 μg/m3, p = 0.02).”
Quote in the paperNot a substantial claim - Findingown data
TTVOC concentrations did not differ significantly among rooms.
“TTVOC levels did not vary significantly across rooms (p = 0.8), and outdoor levels were low, frequently below MDLs.”
Quote in the paperNot a substantial claim - Findingown data
n-Tetradecane concentrations in the break room exceeded those elsewhere (11 vs 0.8 μg/m3, p < 0.05).
“In the break room, alkane levels were slightly higher than levels elsewhere (22 ± 17 μg/m3 versus 6.2 ± 6.0 μg/m3, p = 0.09), largely due to n-tetradecane (11 μg/m3 versus 0.8 μg/m3, p < 0.05).”
Quote in the paperNot a substantial claim - Findingown data
VOC concentrations were inversely correlated with estimated air change rates.
“VOC levels were negatively correlated with estimated air change rates.”
Quote in the paperNot a substantial claim - Findingown data
Break room alkane concentrations were slightly higher than elsewhere (22 ± 17 vs 6.2 ± 6.0 μg/m3, p = 0.09).
“In the break room, alkane levels were slightly higher than levels elsewhere (22 ± 17 μg/m3 versus 6.2 ± 6.0 μg/m3, p = 0.09), largely due to n-tetradecane (11 μg/m3 versus 0.8 μg/m3, p < 0.05).”
Quote in the paperNot a substantial claim - Findingown data
A preliminary study by the authors found that local hotel cleaning products contained VOCs such as toluene, ethylbenzene, xylene, styrene, α-pinene, n-decane, p-isopropyl toluene, limonene, nonanal, and n-dodecane.
“In a preliminary study, we found that cleaning products used in local hotels contained these and other VOCs, e.g., toluene, ethylbenzene, xylene, styrene, α-pinene, n-decane, p-isopropyl toluene, limonene, nonanal, and n-dodecane.”
Quote in the paperSubstantial claim - Findingown data
Laundry workers had the highest personal aromatic VOC concentrations among hotel workers (8.6 ± 0.8 vs 3.7 ± 2.3 μg/m3, p = 0.02).
“Aromatic VOCs had lower levels in the lobby than other indoor sites (0.9 ± 0.3 μg/m3 versus 3.9 ± 3.2 μg/m3, p = 0.07), and laundry workers had the highest personal measurements among hotel workers (8.6 ± 0.8 μg/m3 versus 3.7 ± 2.3 μg/m3, p = 0.02).”
Quote in the paperSubstantial claim - Findingown data
Indoor temperatures and TTVOC concentrations were positively correlated (p = 0.02).
“Indoor temperatures and TTVOC concentrations were positively correlated (Figure S3, p = 0.02).”
Quote in the paperNot a substantial claim - Findingown data
For other hotel workers, most (>84%) of non-cancer risk was from formaldehyde.
“For other hotel workers, most (>84%) of the non-cancer risk was from formaldehyde.”
Quote in the paperNot a substantial claim - Findingown data
PCA Factor 2 had high loadings of chloroform and carbon tetrachloride.
“Factor 2 had high loadings of chloroform and carbon tetrachloride,”
Quote in the paperNot a substantial claim - Findingown data
Outdoor CO2 averaged 414 ± 27 ppm.
“Outdoor CO2 levels averaged 414 ± 27 ppm.”
Quote in the paperNot a substantial claim - Findingown data
In the present study, formaldehyde levels in break and laundry rooms averaged 12 μg/m3, at the lower range found in US buildings.
“In the present study, formaldehyde levels in the break and laundry rooms averaged 12 μg/m3, at the lower range found in the US buildings.”
Quote in the paperNot a substantial claim - Findingown data
Indoor CO2 in Hotel 1 averaged 604 ± 196 ppm.
“Indoor CO2 concentrations in Hotel 1 averaged 604 ± 196 ppm (Table 2)”
Quote in the paperNot a substantial claim - Findingown data
Laundry and maintenance workers had slightly higher hazard ratios (0.4 and 0.5, respectively).
“laundry and maintenance workers had slightly higher HRs (0.4 and 0.5, respectively, Table 3).”
Quote in the paperNot a substantial claim - Findingown data
Laundry workers had the highest cancer risk (6.4 ± 2.8 ×10−5, p = 0.05).
“laundry workers had the highest CR (6.4 ± 2.8 ×10−5, p = 0.05).”
Quote in the paperNot a substantial claim - Findingown data
Chloroform was not detected in the laundry products.
“Chloroform was not detected in the laundry products;”
Quote in the paperNot a substantial claim - Findingown data
For maintenance workers, formaldehyde (46%) and n-nonane (54%) were the largest contributors to the hazard ratio.
“For maintenance workers, formaldehyde (46%) and n-nonane (54%) were the largest contributors to the HR.”
Quote in the paperNot a substantial claim - Findingown data
38 VOCs were detected in the three laundry products tested.
“We detected 38 VOCs in the three laundry products tested.”
Quote in the paperNot a substantial claim - Findingcitation
The relatively high hazard ratio and low cancer risk for the maintenance worker resulted from n-nonane at 24 μg/m3.
“The relatively high HR and low CR for the maintenance worker resulted from n-nonane (24 μg/m3),”
Quote in the paperNot a substantial claim - Findingown data
Hazard ratios averaged 0.3 ± 0.06 among workers.
“Hazard ratios (HRs), which reflect the possibility of non-cancer health effects due to VOC exposure, averaged 0.3 ± 0.06 among workers in the study;”
Quote in the paperNot a substantial claim - Findingown data
PCA Factor 1 had high loadings of heptanal, octanal, nonanal, limonene, n-tetradecane, and n-pentadecane.
“Factor 1 had high loadings of heptanal, octanal, nonanal (aldehydes), limonene (terpene) and n-tetradecane, n-pentadecane (alkanes).”
Quote in the paperNot a substantial claim - Findingown data
31 VOCs were detected in the four cleaning products.
“A total of 31 VOCs was detected in the four cleaning products,”
Quote in the paperNot a substantial claim - Findingown data
The break room had the highest average CO2 (716 ± 239 ppm) compared with laundry (550 ± 125 ppm) and guest rooms (491 ± 46 ppm).
“The break room, which usually had the most occupants, had the highest average CO2 level (716 ± 239 ppm) compared to the laundry (550 ± 125 ppm) and guest rooms (491 ± 46 ppm).”
Quote in the paperNot a substantial claim - Findingown data
Estimated excess cancer risk from VOC exposure averaged 4.1 ×10−5 among workers.
“The estimated excess cancer risk (CR) due to VOC exposure averaged 4.1 ×10−5 among the workers;”
Quote in the paperSubstantial claim - Findingown data
Office workers had slightly higher personal limonene concentrations than housekeepers (12 ± 9 vs 5.7 ± 8.4 μg/m3, p = 0.07).
“Office workers, who spent time mainly in the lobby, office and break rooms, had slightly higher personal concentrations of limonene than housekeepers (12 ± 9 versus 5.7 ± 8.4 μg/m3, p = 0.07);”
Quote in the paperNot a substantial claim - Findingown data
Most other PCA factors had a single dominant VOC.
“Most of the other factors had a single dominant VOC.”
Quote in the paperNot a substantial claim - Findingown data
Maintenance workers had higher personal α-pinene concentrations than other workers (7.8 vs 0.9 μg/m3, p = 0.09).
“The maintenance workers had higher personal concentrations of α-pinene than other workers (7.8 μg/m3 versus 0.9 μg/m3, p = 0.09).”
Quote in the paperNot a substantial claim - Findingown data
Terpenes, mainly limonene, were the dominant VOC in dust cleaners, floor cleaners, and smoke remover.
“Terpenes (mainly limonene) were the dominant VOC in dust cleaners (0.1 μg/mL), floor cleaners (0.7 μg/mL) and smoke remover (64 μg/mL).”
Quote in the paperNot a substantial claim - Findingown data
ACRs were negatively associated with TTVOC levels (p = 0.01, excluding one summer break room outlier).
“ACRs were negatively associated with TTVOC levels (Figure 2; p = 0.01; this excludes one summer observation in the break room that appears to be an outlier).”
Quote in the paperNot a substantial claim - Findingcitation
In Hotel 1, temperatures mostly remained within the comfort range of 20-27 °C.
“In Hotel 1, temperatures mostly remained within the comfort range (20−27 °C) [42].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [42] source
- Findingnone given
Compared with retail and restaurant industries, hotel housekeepers had lower formaldehyde and BTEX levels.
“In comparison to retail and restaurant industries, hotel housekeepers had lower levels of formaldehyde and BTEX.”
Quote in the paperNot a substantial claim - Findingown data
Chloroform was present in the laundry room at 4 μg/m3.
“While present in the laundry room at 4 μg/m3,”
Quote in the paperNot a substantial claim - Findingreasoning
Chloroform levels in personal samples of laundry workers were not significantly elevated.
“and chloroform levels in personal samples of the laundry workers were not significantly elevated,”
Quote in the paperNot a substantial claim - Findingown data
Several cleaning products in this study contained chlorinated compounds.
“as found in several cleaning products in this study (Table S5).”
Quote in the paperNot a substantial claim - Findingown data
Calculated hazard ratios fall below one (range 0.3-0.5).
“Calculated HRs fall below one (range: 0.3–0.5),”
Quote in the paperSubstantial claim - Findingnone given
Cancer risks were driven by chloroform and formaldehyde.
“Cancer risks were driven by chloroform and formaldehyde.”
Quote in the paperSubstantial claim - Findingown data
Non-cancer risks were driven by n-nonane and formaldehyde.
“Non-cancer risks were driven by n-nonane and formaldehyde,”
Quote in the paperSubstantial claim - Findingown data
Terpenes were not detected in outdoor samples.
“Terpenes were not detected in outdoor samples.”
Quote in the paperNot a substantial claim - Findingown data
The laundry detergent contained a high concentration of n-tetradecane.
“As shown in Table S5, the laundry detergent contained a high concentration of n-tetradecane.”
Quote in the paperNot a substantial claim - Findingown data
Chloroform was not present in the laundry products.
“chloroform was not present in the laundry products,”
Quote in the paperNot a substantial claim - Findingown data
Formaldehyde, chloroform, and several alkanes were the most significant VOCs from a health risk perspective.
“Formaldehyde, chloroform and several alkanes were the most significant VOCs from a health risk perspective.”
Quote in the paperSubstantial claim - Findingown data
Formaldehyde contributed over half of the health risk in this study.
“Formaldehyde, contributing over half of the health risk in this study,”
Quote in the paperSubstantial claim - Findingown data
Estimated lifetime risks for these chemicals range from 3 to 44 × 10−6.
“Estimated lifetime risks for these chemicals, in the range of 3−44 × 10−6,”
Quote in the paperSubstantial claim - Premisecitation
Terpenes and other unsaturated VOCs can react with airborne ozone to form secondary pollutants such as formaldehyde, acetaldehyde, free radicals, and ultrafine particles.
“Unsaturated VOCs (e.g., terpenes) can react with ozone in air to generate secondary pollutants, such as formaldehyde and acetaldehyde, free radicals and ultrafine particles [13] that also pose health risks [14].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [13] source
- Interpretationown data
The VOC concentrations and estimated health risks in this study fell in the lower range reported for US buildings.
“VOC levels and the derived health risks in this study were at the lower range found in the US buildings.”
Quote in the paperNot a substantial claim- The authors state this as an assumption: The risk calculations assume a 40-hour work week.
- Interpretationown data
Chloroform and formaldehyde were among the VOCs of greatest health concern.
“VOCs of greatest health significance included chloroform and formaldehyde.”
Quote in the paperSubstantial claim- The authors state this as an assumption: The risk calculations assume a 40-hour work week.
- Interpretationown data
Product and air sample composition and concentrations helped identify likely VOC emission sources: building sources for formaldehyde, laundry-room disinfection byproducts, and cleaning products.
“The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection byproducts in the laundry room, and cleaning products.”
Quote in the paperSubstantial claim - Premisecitation
Hotel housekeepers' job tasks, workload, and work intensity raise their exposure to physical, chemical, biological, and psychosocial hazards.
“The nature of the hotel housekeepers’ job tasks, workload and work intensity increase exposure to physical (back injuries, and sprains), chemical (concentrated cleaning products, and fragranced products), biological (blood, body fluids, and microbe), and psychosocial (low respect, and discrimination) hazards [7, 8].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [7] source
- cites [8]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The US NIOSH Total Worker Health initiative identifies hotel housekeepers as a high-priority at-risk group.
“Hotel housekeepers have been identified as a high priority at-risk group in the US National Institute for Occupational Safety and Health (NIOSH) Total Worker Health initiative [4].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [4]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Cleaning and fragrance products contain many VOCs, including benzene, chloroform, ethylbenzene, carbon tetrachloride, and dichlorobenzenes.
“Cleaning and fragrance products contain many VOCs, such as benzene, chlorobenzene, chloroform, 1,4-dioxane, ethylbenzene, 1,1-dichloroethane, 1,2-dichloropropane, carbon tetrachloride, trichloroethene, bromodichloromethane, 1,2-dichlorobenzene, and 1,3-dichlorobenzene [9, 10].”
Quote in the paperSubstantial claim0 of 2 sources checked - Interpretationown data
Some workers were exposed to alkanes at levels that could produce non-cancer effects.
“Several workers had exposure to alkanes that could cause non-cancer effects.”
Quote in the paperNot a substantial claim- The authors state this as an assumption: The risk calculations assume a 40-hour work week.
- Interpretationown data
The overlapping VOC groups in PCA reflect multiple emission sources in hotels.
“reflecting the multiple emission sources in hotels.”
Quote in the paperNot a substantial claim - Interpretationown data
Many target VOCs were undetected, due to lack of sources or high method detection limits caused by short sampling periods (6-9 hours).
“Many of the target VOCs were undetected, either due to a lack of sources or due to somewhat high method detection limits, largely caused by the relatively short sampling periods (6−9 hours) needed to match the housekeepers’ schedules.”
Quote in the paperNot a substantial claim - Interpretationown data
Indoor CO2 levels depended on the number of occupants, ventilation conditions, and other factors.
“and levels depended on the number of occupants, ventilation conditions, and other factors.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Factor 1 likely reflected emissions from multiple cleaning products used.
“Based on the composition and concentrations of cleaning products, this factor likely reflected emission from the multiple cleaning products used.”
Quote in the paperNot a substantial claim - Interpretationown data
The similarity of VOC compositions in the break room to personal samples suggests most workers spent at least some time in the break room.
“The similarity of VOC compositions in the break room to personal samples suggests that most workers spent at least some time in the break room (Figure 1).”
Quote in the paperNot a substantial claim - Premisecitation
Measurements in 14 US retail stores showed slightly higher formaldehyde (22 μg/m3) and BTEX (9.5 ppb) than the present study's personal measurements (12 and 4.0 μg/m3).
“Measurements in 14 US retail stores [53] showed slightly higher levels of formaldehyde (averaging 18 ppb = 22 μg/m3) and BTEX (9.5 ppb) than the present study (personal measurements of 12 and 4.0 μg/m3 respectively);”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [53]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationown data
Factor 2 reflected contributions from bleach.
“reflecting contributions from bleach.”
Quote in the paperNot a substantial claim - Interpretationreasoning
VOC patterns observed among indoor and personal samples are not unique or distinctive because work tasks and sites are dynamic and overlap.
“VOC patterns observed among both indoor and personal samples are not unique or distinctive since work tasks and work sites are dynamic and overlap, e.g., laundry workers also collect items throughout the hotel, and office workers may assist with housekeeping (folding clean towels), provide supervision throughout the building, and perform light maintenance.”
Quote in the paperNot a substantial claim - Premisecitation
n-Nonane and formaldehyde are irritants to the eyes, mucous membranes, and upper respiratory tract.
“which are irritants to the eyes, mucous membranes and upper respiratory tract [60, 80, 81].”
Quote in the paperSubstantial claim0 of 3 sources checked - Premisecitation
VOC levels can increase considerably with new construction, certain building products, and renovations.
“VOC levels can increase considerably with new construction, certain building products and renovations [52].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [52] source
- Interpretationown data
Cleaning products were likely the major source of terpenes.
“Cleaning products were likely the major source of terpenes (Table S4).”
Quote in the paperNot a substantial claim - Interpretationreasoning
For housekeepers, personal samples reflect the potential for closer contact with VOCs in cleaning products and other products.
“For housekeepers, such samples reflect the potential of closer contact with VOCs in cleaning products and other products.”
Quote in the paperNot a substantial claim - Interpretationreasoning
VOC levels in hotels may be highest in summer due to increased volatility and lower ACRs.
“VOC levels in hotels may be highest in summer due to increased volatility and lower ACRs.”
Quote in the paperNot a substantial claim - Premisereasoning
In laundries, clothes dryers exhaust humid air and draw make-up air from the room, which can increase ACRs when the laundry is operating.
“However, in laundries, clothes dryers exhaust humid air and draw make-up air from the room, which can increase ACRs when the laundry is operating.”
Quote in the paperNot a substantial claim - Interpretationown data
The strong negative association between ACRs and TTVOC concentrations demonstrates the importance of ACR.
“The importance of ACR was demonstrated by the strong negative association between ACRs and TTVOC concentrations (Figure 2).”
Quote in the paperSubstantial claim - Study design and conductreasoning
The health risk estimates are not necessarily representative of long-term exposures or a broader population.
“While not necessarily representative of long-term exposures or a broader population, our data suggest several findings.”
Quote in the paperNot a substantial claim - Interpretationown data
The low VOC and CO2 levels found in the study hotels demonstrate the effectiveness of appropriate ventilation rates in minimizing exposure.
“Still, the low VOC (and CO2) levels found in the study hotels demonstrate the effectiveness of appropriate ventilation rates in minimizing exposure.”
Quote in the paperNot a substantial claim - Premisecitation
Lower ACRs in summer, as reported elsewhere, can result from air conditioning, reduced HVAC fan speeds, smaller indoor-outdoor temperature gradients, and lower wind velocities.
“Lower ACRs in summer, as reported elsewhere [78], can result from the use of air conditioning, reduced HVAC fan speeds, smaller indoor-outdoor temperature gradients, and lower wind velocities.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [78] source
- Premisecitation
Chloroform and carbon tetrachloride are the dominant halogenated VOCs formed by chlorine bleach.
“Chloroform and carbon tetrachloride are the dominant halogenated VOCs formed by chlorine bleach [10, 68].”
Quote in the paperNot a substantial claim0 of 2 sources checked - Study design and conductreasoning
Conditions in the study hotels cannot be assumed to apply more broadly.
“However, conditions in the study hotels cannot be assumed to apply more broadly, and studies at additional hotels are needed to characterize chemical exposure in the large population of hotel housekeepers.”
Quote in the paperSubstantial claim - Interpretationown data
Appropriate ventilation helped keep VOC concentrations and derived health risks low.
“appropriate ventilation helped keep VOC concentrations and derived health risks low”
Quote in the paperSubstantial claim - Interpretationown data
In this small sample of hotels, VOC exposure may not be a priority occupational risk for hotel housekeepers.
“In our small sample of hotels, this suggests that VOC exposure is not a priority issue for hotel housekeepers.”
- Also stated in: § CONCLUSIONS · hedged
“While indoor sources were identified, appropriate ventilation helped keep VOC concentrations and derived health risks low, and thus VOC exposure may not be a priority occupational risk for hotel housekeepers in this study.”
Quote in the paperSubstantial claim - Also stated in: § CONCLUSIONS · hedged
- Classified as probably not a substantial claim. 43
- May combine two claims. 94
Classified as probably not a substantial claim. May combine two claims.
Study design and conductown dataAir change rates were estimated with CO2 as a natural tracer gas and the decay method, using at least two decay curves per space that showed at least 100 ppm change and an approximately expected exponential decline.
“Air change rates (ACRs) were estimated for the break, guest and laundry rooms using CO2 as a “natural” tracer gas and the decay method [37, 38].”
- Also stated in: § Data analysis · plain
“We used as many decay curves as possible (at least two curves) for each space, selecting curves that had at least 100 ppm change and that followed (at least roughly) the expected declining exponential trend.”
Quote in the paperSubstantial claim1 of 2 sources checked- Also stated in: § Data analysis · plain
May combine two claims.
PremisecitationPersonal exposure measurements usually exceed indoor or area sampling levels; in hotels, this may be because housekeepers work in close, direct contact with cleaning agents.
“This omission is important since personal measurements typically exceed levels measured using indoor or area sampling; in hotels, this may result due to housekeepers’ close and direct contact with cleaning agents [25].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [25] source
The Results and discussion section (page unavailable) reports that personal VOC measurements in nail salons generally exceeded area measurements, particularly for chemicals associated with salon products. The paper does not study hotels or housekeepers, so it does not establish that direct contact with cleaning agents explains their exposures. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationMuch higher formaldehyde levels have been reported in Chinese hotel rooms, including 60-290 μg/m3, 114 μg/m3 in new hotels, 140 μg/m3 in newly furnished rooms, and 10 μg/m3 in older rooms.
“Much higher formaldehyde levels have been reported in Chinese hotel rooms, e.g., 60–290 μg/m3 [51], 114 μg/m3 in new hotels [22], 140 μg/m3 in newly furnished rooms, and 10 μg/m3 in older rooms [52].”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [51] source
Citation [22] is attached specifically to the claim of 114 μg/m³ in new Chinese hotels. The Evaluation of Data table reports 29.7 μg/m³ for Chinese hotel ballrooms, but that is a different setting; searches for 114 μg/m³ and new hotel rooms found no matching passage in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [22] source
- cites [52] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn 126 homes in Detroit, TTVOC concentrations averaged 150 μg/m3 (range 14-2274 μg/m3).
“For example, in 126 homes in Detroit, Michigan, USA, TTVOC concentrations averaged 150 μg/m3 (range: 14−2274 μg/m3) [31].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [31] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationChlorinated compounds include relatively non-polar solvents that are also found in cleansing agents.
“Chlorinated compounds include relatively non-polar solvents that are also found in cleansing agents [70],”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [70] source
The discussion of tap-water contaminants (pp. 47–50) addresses exposure to chloroform and trichloroethene, but does not describe them as relatively non-polar solvents or say they are found in cleansing agents. Searches for those terms and for cleaning agents found no passage supporting that description; a reference to dry cleaners does not establish the claim. (LLM, conf=0.75)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationFormaldehyde is classified as a probable human carcinogen by the US EPA and as a human carcinogen by IARC; it is associated with nasopharynx, sinonasal, and leukemia cancers.
“Formaldehyde is classified as a probable human carcinogen by the US EPA [89] and as a human carcinogen by the IARC [90, 91]; it is associated with nasopharynx, sinonasal and leukemia cancers [92].”
Quote in the paperSubstantial claim1 of 4 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFormaldehyde is a widespread indoor air pollutant affecting homes, schools, and many other environments.
“formaldehyde, which is a widespread indoor air pollutant affecting homes, schools and many other environments [93–95].”
Quote in the paperNot a substantial claim1 of 3 sources checkedMay combine two claims.
Findingown dataOffice workers had the highest personal methylene chloride concentrations (22 μg/m3), close to the lobby concentration (28 μg/m3).
“Methylene chloride was found in all personal and lobby samples in winter (average of 7.5 ± 2.5 μg/m3 among housekeepers), and office workers had the highest personal concentrations, 22 μg/m3, just similar to the lobby level (28 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataHexanal was detected in two guest room samples and two laundry room samples, with higher concentrations in guest rooms than laundry rooms.
“Hexanal was found in two guest room samples and two laundry room samples; the level in the guest rooms was higher than in the laundry rooms.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataBenzene was detected in 91% of indoor samples and 82% of personal samples.
“Benzene was found in most indoor and personal samples (91 and 82%), and a room cleaner had the highest personal measurement (3.0 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataToluene was the main BTEX component, averaging 6.6 ± 3.7 μg/m3 among laundry workers.
“Toluene was the dominant BTEX component (6.6 ± 3.7 μg/m3 for laundry workers), and this compound was found in most indoor and personal samples (both 73%); a laundry worker had the highest personal measurement (9.2 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown data1,4-Dichlorobenzene was detected only in room cleaners' personal samples, averaging 0.3 μg/m3.
“1,4-dichlorobenzene was found only in personal samples of room cleaners (average of 0.3 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataOutdoor TTVOC concentrations were low and often below method detection limits.
“TTVOC levels did not vary significantly across rooms (p = 0.8), and outdoor levels were low, frequently below MDLs.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataHexanal was detected in nine room cleaner samples and one laundry worker sample, mostly in winter.
“Hexanal was found in 9 room cleaner samples and one laundry worker sample, mostly during winter sampling.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataBTEX concentrations were higher in guest and laundry rooms (4.4 ± 3.3 μg/m3) and lower in the lobby (0.7 ± 0.05 μg/m3).
“BTEX levels were higher in guest and laundry rooms (4.4 ± 3.3 μg/m3) and lower in the lobby (0.7 ± 0.05 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIn winter, methylene chloride was detected in all personal and lobby samples, averaging 7.5 ± 2.5 μg/m3 among housekeepers.
“Methylene chloride was found in all personal and lobby samples in winter (average of 7.5 ± 2.5 μg/m3 among housekeepers), and office workers had the highest personal concentrations, 22 μg/m3, just similar to the lobby level (28 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataLaundry room chloroform concentrations averaged 4.0 μg/m3, significantly higher than elsewhere (average 0.04 μg/m3, p = 0.02).
“Chloroform averaged 4.0 μg/m3 in the laundry room, significantly higher than at other locations (average of 0.04 μg/m3, p = 0.02), and personal measurements averaged 3.3 μg/m3 among the laundry workers, although this was not significantly higher than other workers.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIndoor TTVOC concentrations averaged 28 ± 15 μg/m3, with seasonal variation from 19 ± 2 μg/m3 in spring to 43 ± 24 μg/m3 in summer.
“For the indoor samples, TTVOC levels averaged 28 ± 15 μg/m3 and varied seasonally (p = 0.06) from 19 ± 2 μg/m3 in spring to 43 ± 24 μg/m3 in summer.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataTTVOC concentrations did not differ significantly by worker group, season, or hotel.
“TTVOC levels did not vary by worker group (p = 0.8), season (p = 0.4), or hotel (p = 0.2).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataHeptanal and octanal were detected only in room cleaners, averaging 0.8 and 1.5 μg/m3, respectively.
“Among personal samples, heptanal and octanal were detected in only room cleaners, averaging 0.8 and 1.5 μg/m3, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIndoor BTEX concentrations varied by season (p = 0.09), with higher summer levels (6.0 ± 3.9 μg/m3) than other seasons (1.9 ± 1.6 μg/m3, p < 0.05).
“Levels of the BTEX compounds (benzene, toluene, ethylbenzene, xylene) varied seasonally in indoor samples (p = 0.09), and were higher in summer (6.0 ± 3.9 μg/m3) than in other seasons (1.9 ± 1.6 μg/m3, p < 0.05).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataLaundry workers' personal chloroform concentrations averaged 3.3 μg/m3, not significantly higher than other workers.
“Chloroform averaged 4.0 μg/m3 in the laundry room, significantly higher than at other locations (average of 0.04 μg/m3, p = 0.02), and personal measurements averaged 3.3 μg/m3 among the laundry workers, although this was not significantly higher than other workers.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataPentanal was detected in all guest rooms, averaging 4.4 ± 2.7 μg/m3, significantly higher than at other indoor sites (1.0 μg/m3, p < 0.05).
“Pentanal was found in all guest rooms, averaging 4.4 ± 2.7 μg/m3, significantly higher than other indoor sites (1.0 μg/m3, p < 0.05).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataToluene was detected in 73% of indoor samples and 73% of personal samples.
“Toluene was the dominant BTEX component (6.6 ± 3.7 μg/m3 for laundry workers), and this compound was found in most indoor and personal samples (both 73%); a laundry worker had the highest personal measurement (9.2 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataFormaldehyde concentrations averaged 10 ± 6 μg/m3 in break rooms and 14 ± 6 μg/m3 in laundry rooms.
“Formaldehyde, a toxic aldehyde, averaged 10 ± 6 and 14 ± 6 μg/m3 in the break and laundry rooms, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataLimonene and α-pinene were detected in most samples, and personal concentrations were much higher than indoor concentrations.
“Among the terpenoid VOCs, limonene and α-pinene were found in most samples, and personal levels were considerably higher than the indoor samples.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataPCA using guest room and room cleaner VOC levels in Hotel 1 produced 9 factors and many overlapping VOC groups.
“PCA results obtained using guest room and room cleaner VOC levels in Hotel 1 (Table S4) yielded 9 factors and many overlapping VOC groups,”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationRelative humidity was not consistently maintained in the comfort range of 30-60%, peaking at 63 ± 7% in summer and falling to 21 ± 3% in winter.
“In contrast, the RH was not consistently maintained in the comfort range (30−60%) [42], peaking to 63 ± 7% in summer and falling to 21 ± 3% in the winter heating season.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [42] source
May combine two claims.
Findingown dataTerpene concentrations in the break room averaged 7.5 ± 6.7 μg/m3, slightly above other indoor sites at 0.9 ± 1.0 μg/m3 (p = 0.09).
“Terpenes averaged 7.5 ± 6.7 μg/m3 in the break room, slightly higher than at other indoor sites (0.9 ± 1.0 μg/m3, p = 0.09).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataAlkanes were the dominant VOC in glass cleaner, comprising 79% and mainly n-hexadecane.
“Alkanes were the dominant (79%) VOC in the glass cleaner (mainly n-hexadecane, Figure S2 and Table S5).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe break room ACR was higher at 2.8 h−1 and most variable (COV = 57% in summer).
“The ACR in the break room was higher, 2.8 h−1, and the most variable (COV = 57% in summer).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataFormaldehyde concentrations were relatively low but exceeded the US EPA reference value.
“Formaldehyde concentrations were also relatively low, although they exceeded the US EPA reference value.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataPersonal VOC concentrations exceeded indoor concentrations, with personal samples about twice indoor levels.
“Overall, VOC levels in personal samples exceeded levels in the indoor samples.”
- Also stated in: § Factors influencing VOC level · plain
“Personal samples had almost twice the concentrations of VOCs than the indoor samples.”
- Also stated in: § CONCLUSIONS · plain
“Concentrations measured using personal sampling were about twice those of the indoor sampling.”
Quote in the paperNot a substantial claim- Also stated in: § Factors influencing VOC level · plain
May combine two claims.
Findingown dataTemperatures in the connected lobby and break rooms were similar and did not vary seasonally; temperatures in laundry and guest rooms correlated with outdoor temperatures.
“Temperatures in the connected lobby and break rooms were similar and did not vary seasonally; temperatures in the laundry and guest rooms, which are separate and independent spaces, were correlated with outdoor temperatures (Table 2).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataTTVOC concentrations in detergent, booster, and fabric softener were 96, 0.1, and 35 μg/mL, respectively.
“TTVOC concentrations in detergent, booster and fabric softener were 96, 0.1 and 35 μg/mL, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataTTVOC levels in dust, floor, glass, and smoke cleaners were 0.3, 1.0, 0.2, and 69 μg/mL, respectively.
“and TTVOC levels were 0.3, 1.0, 0.2 and 69 μg/mL in the dust, floor, glass and smoke cleaners, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataCompared with US offices, the study found similar BTEX, styrene, and terpene levels, somewhat lower formaldehyde, and higher chloroform especially in laundry rooms.
“In comparison to studies in US offices, we found similar levels of BTEX, styrene and terpenes, somewhat lower formaldehyde levels, and higher chloroform levels, especially in laundry rooms.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIn the two hotels, indoor and personal TTVOC averaged 28 and 57 μg/m3; BTEX averaged 3.0 and 3.8 μg/m3; and toluene averaged 1.7 and 2.3 μg/m3.
“Overall, we found low VOC levels in the two hotels, e.g., indoor and personal samples averaged 28 and 57 μg/m3 for TTVOC, respectively; BTEX averaged 3.0 and 3.8 μg/m3; and toluene averaged 1.7 and 2.3 μg/m3.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe laundry room ACR was similar at 2.6 h−1 and changed seasonally, lower in summer than winter or spring (p = 0.04).
“The ACR in the laundry room was similar, 2.6 h−1, and changed seasonally (lower in summer compared to winter or spring, p = 0.04).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataSeveral halohydrocarbons were detected in fabric softener and booster (0.09 and 0.01 μg/mL) but not in detergent.
“Several halohydrocarbons were detected in the fabric softener and booster (0.09 and 0.01 μg/mL), but not in the detergent.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataMost (>68%) of the cancer risk was due to formaldehyde, followed by chloroform and benzene.
“Most (>68%) of the CR is due to formaldehyde, followed by chloroform and benzene (Table 3).”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe most prevalent VOCs in detergent were alkanes (87 μg/mL, primarily n-tetradecane), consistent with personal samples of laundry workers.
“The most prevalent VOCs in detergent were alkanes (87 μg/mL, primarily n-tetradecane), which is consistent with the composition of personal samples of laundry workers (Figure 1).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe dominant VOCs in laundry products were alkanes in detergent, terpenes in fabric softener, and aldehydes in booster.
“The dominant VOCs in these products were alkanes (detergent), terpenes (fabric softener) and aldehydes (booster; Table S5 and Figure S2).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataACRs in guest rooms averaged 1.5 h−1 and did not vary by season.
“Based on the decay models, ACRs in guest rooms averaged 1.5 h−1 and did not vary by season.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataAll cleaning products in this study contained terpenes, averaging 13 μg/mL (40% of TTVOCs); the smoke remover contained 64 μg/mL.
“All cleaning products in this study contained terpenes, averaging 13 μg/mL (40% of TTVOCs); the smoke remover contained 64 μg/mL.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationThe estimated average ACR was 2.5 hr−1 (range 0.6-3.7 hr−1), similar to previous studies.
“We estimated an average ACR of 2.5 hr−1 (range: 0.6–3.7 hr−1), similar to previous studies [22, 76–78].”
Quote in the paperNot a substantial claim0 of 4 sources checkedMay combine two claims.
Findingown dataMost (82-86%) indoor and personal samples contained terpenes, with average levels of 2.7 and 7.7 μg/m3, respectively.
“Most (82−86%) of the indoor and personal samples contained terpenes, with an average level of 2.7 and 7.7 μg/m3, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe studied hotels were near busy roads and other VOC sources (e.g., gas station about 200 m distant), outdoor VOC levels were low (benzene did not exceed 0.8 μg/m3), and no combustion sources in the hotels were observed.
“While the studied hotels were near busy roads and other VOC sources (e.g., gas station ~200 m distant), outdoor VOC levels were low (e.g., benzene levels did not exceed 0.8 μg/m3), and no combustion sources in the studied hotels were observed.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataNo significant difference in BTEX concentrations was found between smoking and non-smoking workers, or between workers reporting passive smoke exposure and others.
“We found no significant difference in BTEX concentrations among smoking and non-smoking workers, or between workers that reported exposure to passive smoke (cleaning rooms with tobacco odors) and others.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataAll tested cleaning products contained alkanes with an average proportion of 35% (91% in laundry detergent and 79% in glass cleaner).
“All of the tested cleaning products contained alkanes with an average proportion of 35% (91 and 79% in the laundry detergent and glass cleaner, respectively).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataMethylene chloride was not found in any cleaning products but was found in the lobby and personal samples of office workers.
“Methylene chloride was not found in any cleaning products, but this compound was found in the lobby and in personal samples of office workers (often staying in the office and lobby).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataAirborne terpene levels were low in the study and no seasonal differences were observed.
“however, airborne terpene levels were low in the study and no seasonal differences were observed (ozone increases in the summer).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingnone givenThe hotels had smoke-free policies, although room cleaners reported tobacco odors in some rooms and some workers smoked outside during break time.
“As noted, the hotels had “smoke-free” policies although room cleaners reported tobacco odors in some rooms, and some workers smoked outside during break time.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataMost indoor and personal samples (91-95%) contained alkanes, which averaged 33-42% of TTVOC concentrations.
“Most indoor and personal samples (91−95%) contained alkanes, which averaged 33−42% of TTVOC concentrations.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataAlkanes were one of the dominant VOC groups in indoor and personal samples and a relatively large contributor (35%) in cleaning products.
“As mentioned, alkanes were one of the dominant VOC groups in indoor and personal samples and a relatively large contributor (35%) in cleaning products.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIn Hotel 1, dryers operated only in winter, when ACR was 3.7 hr−1 compared with 2.9 and 1.4 hr−1 in spring and summer.
“In Hotel 1, the dryers operated only in the winter sampling period, when we determined a relatively high ACR of 3.7 hr−1 (compared to 2.9 and 1.4 hr−1 in spring and summer, respectively).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataWorkers in the studied hotels were exposed to low VOC levels, which resulted in low health risks from VOC exposure.
“Workers in the studied hotels were exposed to low levels of VOCs, which resulted in low health risks from VOC exposure.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataCancer risk exceeded recommended guidelines (1 × 10−6 excess lifetime cancer risk), largely due to formaldehyde.
“In addition, we did find that cancer risk exceeded recommended guidelines (1 × 10−6 of excess lifetime cancer risk), largely due to formaldehyde,”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataCleaning products, especially laundry products, contained a number of aromatic compounds, and bleach use was an important chloroform source.
“Cleaning products (especially laundry products) contained a number of aromatic compounds, and the use of bleach was an important chloroform source.”
Quote in the paperSubstantial claimMay combine two claims.
Study design and conductown dataThe purge duration and other method parameters were optimized to capture at least 90% of VOCs in samples, verified by repeated back-to-back tests.
“The purge duration and other method parameters were optimized to collect at least 90% of VOCs present in the samples, as determined in repeated (back-to-back) tests of the same sample.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataThe University of Michigan IRB approved the study protocols and consent forms.
“study protocols, consent forms, and other study aspects were approved by the University of Michigan IRB office.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataMost compounds had recovery rates between 80% and 120%.
“Recovery rates for most compounds ranged between 80 and 120%.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataLaboratory blanks and duplicates, 43% of samples, were obtained during cleaning product testing.
“Laboratory blanks and duplicates (43% of samples) were also obtained when testing the cleaning products.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataAll participants provided written informed consent.
“Written informed consent in Spanish or English was obtained from all participants”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataDaily check results differed from calibration results by less than 30%.
“A freshly loaded adsorbent tube injected with 10 ng of standards was analyzed daily, and differences between the daily checks and calibration results were within 30%.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe mean hourly wage for hotel housekeeping is $12.30, making it a low-wage occupation.
“Hotel housekeeping is a low-wage occupation, with a mean hourly wage of $12.30 [1].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [1]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationProduct labels generally do not list the complete chemical composition of cleaning products, and fragrance chemicals need not be disclosed.
“We also note that the full chemical composition of cleaning products generally is not listed on product labels. Chemical disclosure is not required for the fragrances used in many products, which may be composed of mixtures of dozens to hundreds of chemicals [19–21].”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataMethod detection limits ranged from 0.02 to 2.5 μg/m3.
“Method detection limits (MDLs), determined as the standard deviation of seven replicate low concentration injections multiplied by 3.707 [34], ranged from 0.02 to 2.5 μg/m3.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataBlanks showed trace contamination below 8 ng for 10 compounds, and blank-corrected results were used for those compounds.
“Trace level contamination (<8 ng) was detected in blanks for 10 compounds (methylene chloride, hexane, benzene, toluene, hexanal, ethylbenzene, p-, m-xylene, styrene, nonanal, and naphthalene); blank-corrected results were used for these compounds.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataMultipoint calibrations were performed.
“Multipoint calibrations (1, 3, 10, 30, and 100 ng) were performed.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe hospitality sector is the third largest US industry, employing 1.8 million workers, and hotel housekeepers are its largest workforce.
“Hotel housekeepers are the largest workforce in the hospitality industry, which is the third largest industry in the US with 1.8 million workers [1].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [1]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationHotel housekeepers are a large, low-income, predominantly minority workforce at high risk.
“Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce.”
- Also stated in: § INTRODUCTION · plain
“Hotel housekeepers represent a low-income, minority and high-risk group that has garnered little attention.”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [1]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [2]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [3] source
- cites [4]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Also stated in: § INTRODUCTION · plain
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenField blanks and duplicates, about 10% of samples, were used on each field sampling day.
“Field blanks and duplicates, representing about 10% of samples, were utilized during each field sampling day.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationReference concentrations and unit risk values were obtained from the US EPA and the Michigan Department of Environment, Great Lakes and Energy.
“Parameters including the RfC and UR values (Table S2) were obtained from the US Environmental Protection Agency (EPA) [35] and the Michigan Department of Environment, Great Lakes and Energy [36].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [36]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationImmigrant women, people of color, and contingent workers make up most hotel housekeepers.
“Most hotel housekeepers are immigrant women, people of color and contingent workers [2, 3].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [2]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [3] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataTrue duplicates had an average coefficient of variation of 39% across all detected analytes and 22% for analytes above 5 μg/m3.
“The coefficient of variation (COV) of true duplicates averaged 39% across all analytes detected, and the COV was 22% for analytes detected at concentrations above 5 μg/m3.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataFormaldehyde was monitored every 30 minutes with a sensor having a 6 μg/m3 limit of detection.
“Formaldehyde was monitored every 30-min using a colorimetric/photoelectric sensor (FM-801, GrayWolf Sensing Solutions, Shelton, Connecticut, USA). This instrument has a limit of detection (LOD) of 6 μg/m3.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThese formaldehyde measurements frequently exceed the US EPA reference value of 9.8 μg/m3.
“These measurements frequently exceed the US EPA reference value of 9.8 μg/m3 (non-cancer RfC for chronic inhalation exposure) [35].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Premisecitationn-Nonane is associated with eye, skin, and respiratory tract irritation and central nervous system effects, but not cancer.
“which is associated with eye, skin and respiratory tract irritation and central nervous system effects, but not cancer [43].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [43]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationChloroform is a common byproduct of bleach, which is used liberally in hotels, and is also a water disinfection byproduct volatilized from tap water.
“however, this is a common byproduct of bleach, which is used liberally in hotels [10, 39]; chloroform is also a water disinfection byproduct that is volatilized from tap water, particularly from showers and dishwashers [40, 41].”
Quote in the paperNot a substantial claim0 of 4 sources checkedMay combine two claims.
Interpretationown dataThe negative ACR-TTVOC association confirms indoor VOC sources and suggests appropriate ventilation rates are important.
“This association confirms the presence of indoor VOC sources (outdoor sources would not display this relationship), and it suggests the importance of appropriate ventilation rates.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationThe only identified US hotel study sampled exhaust air in a large atrium hotel and reported TTVOC 1125 μg/m3 and toluene 6.2 μg/m3.
“In the US, the only hotel study identified sampled exhaust air in a large atrium hotel and reported TTVOC levels of 1125 μg/m3 (27 compounds, aldehydes excluded) and toluene levels of 6.2 μg/m3 [46].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn the US hotel exhaust air sample, formaldehyde averaged 28 μg/m3.
“In the US hotel (exhaust air sample), formaldehyde averaged 28 μg/m3 [46].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] source
May combine two claims.
PremisecitationSamples from 10 retail shops in a large shopping center (2002-2004) had high toluene and xylene (144 and 3.5 μg/m3) but slightly lower chloroform, methylene chloride, heptane, and hexane than the present study.
“Samples collected at 10 retail shops in a large shopping center from 2002–2004 had high levels of toluene and xylene (144 and 3.5 μg/m3, respectively), but slightly lower levels of chloroform, methylene chloride, heptane and hexane (0.5, 0.8, 1.8 and 3.2 μg/m3) than the present study [56].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [56] source
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThe higher personal limonene among office workers may be due to storage of cleaning products and folding laundry in the break room.
“this may reflect the storage of cleaning products and folding of laundry in the break room.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenVOC levels in hotels and exposures among hotel housekeepers have received little attention.
“While VOC levels have been characterized in many buildings, levels in hotels and exposures among hotel housekeepers have received little attention.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningThe VOC measurements reflect low outdoor concentrations and few strong indoor sources.
“The VOC measurements reflect both low outdoor concentrations, particularly in comparison to the hotel studies in China that were conducted in polluted industrial areas, as well as few strong indoor sources.”
Quote in the paperNot a substantial claimMay combine two claims.
Study design and conductreasoningACRs derived from CO2 may incompletely account for interzonal flows; this is unlikely to affect guest and laundry room estimates but may affect break room estimates because its door was usually open to the lobby.
“In addition, ACRs derived using CO2 may incompletely account for interzonal flows (from other interior spaces); this is unlikely to affect estimates for the guest and laundry rooms; however, since the break room door was usually opened to the lobby, break room ACR estimates may be affected.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductreasoningACR estimates are approximate because measurements can be affected by occupancy changes, HVAC operation, door opening or closing, and weather.
“The ACRs are approximate for several reasons, e.g., measurements can be affected by changes in occupancy, HVAC system operation, opening or closing of doors, and the weather during the measurement period.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningVOC levels in the studied hotels reflect building age (26 years), lack of new furnishings and recent renovation (last 2012), and ACRs sufficient to dilute indoor emissions.
“VOC levels in the studied hotels reflect the buildings’ age (26 years old), the lack of new furnishings and recent or ongoing renovation activities (last renovation was in 2012), and ACRs sufficient to dilute indoor emissions.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationRestaurants had higher BTEX and sometimes chloroform, especially near cooking stoves.
“Restaurants had higher levels of BTEX and sometimes chloroform, especially near cooking stoves in dining areas, for example, at Korean barbeque restaurants [54, 55].”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationSeveral studies in industrial areas of China reported high indoor BTEX and TTVOC levels and high outdoor levels averaging 420 μg/m3.
“Several studies conducted in industrial areas in China have reported high indoor BTEX and TTVOC levels (even though relatively few target VOCs were included) as well as high outdoor levels (averaging 420 μg/m3) [22–24].”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn hostels in New Delhi, India, TTVOC levels averaged 120 μg/m3.
“In hostels in New Delhi, India, TTVOC levels (11 target compounds) averaged 120 μg/m3 [45].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [45]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationPersonal samples of hospital housekeepers showed relatively low VOC concentrations (geometric mean 16 ppb for 11 target VOCs).
“Personal samples of housekeepers at hospitals showed relatively low VOC concentrations (geometric mean of 16 ppb for 11 target VOCs) [57].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [57] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn California offices, individual VOC levels ranged from non-detect to over 1000 μg/m3.
“In offices in California, levels of individual VOCs ranged from non-detect to over 1000 μg/m3 [48, 49].”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenThe PCA results are limited by the sample size.
“The PCA results are also limited by the sample size.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationFormaldehyde typical mean levels are about 20 μg/m3 in US stores, restaurants, and residences, and about 60 μg/m3 in mobile homes.
“Formaldehyde has been measured in many buildings with typical (e.g., mean) levels of ~20 μg/m3 in US stores, restaurants and residences, and higher levels, ~60 μg/m3, in mobile homes [50].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [50] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningThe exhaust air in that US hotel study included bathroom exhaust, which may be atypical of indoor levels.
“However, the exhaust air included bathroom exhaust, which may be atypical of indoor levels.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown dataThe significant association between room temperature and indoor TTVOC level suggests seasonal factors and temperature are important, likely due to increased volatility.
“The significant association between room temperature and indoor TTVOC level suggested the importance of seasonal factors and temperature, likely due to increased volatility.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn hotels and many other buildings, ACRs depend on mechanical system design and operation, infiltration rates, building design, and other factors.
“In hotels and many other buildings, ACRs depend on the design and operation of the mechanical systems, infiltration rates (which depend on indoor-outdoor temperature differences and wind speed [79]), building design, and other factors.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [79] source
May combine two claims.
InterpretationreasoningIn guest and break rooms, ACRs did not vary by season and were likely governed by the HVAC system.
“In the guest and break rooms, ACRs did not vary by season and was likely governed by the HVAC system.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningHigher BTEX in laundry and guest rooms, higher personal concentrations of laundry workers, and presence of BTEX in cleaning products suggest cleaning products are an important source of BTEX (especially toluene) in hotels.
“The higher levels of BTEX compounds found in laundry and guest rooms, the higher personal concentrations of laundry workers, and the presence of BTEX compounds in cleaning products suggest that cleaning products are an important source of BTEX (especially toluene) in hotels.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationcitationThe large amount of bedding and towels in hotels, even with low formaldehyde, will contribute to housekeeper exposures, though several washings are expected to substantially decrease emissions.
“Still, the large amount of bedding and towels used in hotels that contain even low levels of formaldehyde will contribute to housekeeper exposures, although several washings are expected to substantially decrease emissions [65].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [65] source
May combine two claims.
PremisecitationFragrances can contain hundreds of chemicals, some of which may induce adverse health effects, even those labeled organic, green, or all natural.
“Fragrances can contain hundreds of chemicals, some of which may induce adverse health effects, even those labeled as “organic”, “green” or “all natural” [72].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [72]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningBreak rooms and office workers had high n-tetradecane levels, probably from stacked clean towels and laundry detergent.
“Break rooms and office workers had high levels of n-tetradecane, probably from the stacked clean towels and the laundry detergent.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFormaldehyde emissions have been reduced in past decades due to manufacturing changes and standards.
“In past decades, formaldehyde emissions have been reduced due to manufacturing changes and standards [63, 64].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [63] source
- cites [64]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationAt high exposures not found in this study, chloroform can cause central nervous system effects, respiratory depression, delayed hepatotoxicity, kidney and liver damage, and reproductive effects.
“At high exposures (not found in this study), chloroform can cause central nervous system effects, respiratory depression, delayed hepatotoxicity [83], kidney and liver damage, and reproductive effects [84, 85].”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationMethylene chloride sources include products such as paint stripper.
“Methylene chloride sources include products such as paint stripper [71].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [71] source
May combine two claims.
InterpretationcitationA large amount of bleach was used for laundry and room cleaning, suggesting the importance of this source and possibly tap water.
“A large amount of bleach were used for laundry and room cleaning, suggesting the importance of this source [10, 68] and possibly tap water, which frequently contains chloroform as a disinfection byproduct [69].”
Quote in the paperNot a substantial claim0 of 3 sources checkedClassified as probably not a substantial claim. May combine two claims.
InterpretationcitationHazard ratios below one suggest a low likelihood of adverse effects, although a HR threshold of 0.1 is sometimes used for extra safety.
“which suggest a low likelihood of adverse effects, although a HR threshold of 0.1 is sometimes used to provide an extra margin of safety [82].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [82]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFormaldehyde is a possible reaction product between terpenes in cleaning and laundry products and ozone.
“Formaldehyde is also a possible reaction product between terpenes in cleaning and laundry products and ozone [13];”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [13] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAlkanes are in numerous indoor products such as paints, solvents, pesticides, oils, lubricants, and detergents.
“Alkanes are in numerous products used indoors, e.g., paints, solvents, pesticides, oils and lubricants; in addition, they are used in the production of detergents [58–60].”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
Interpretationown dataAlthough VOC levels were not high, indoor levels exceeded outdoor levels and the negative association with ACRs indicate that VOCs primarily arose from indoor sources.
“Although VOC levels were not high, indoor levels exceeded outdoor levels and the negative association with ACRs indicate that VOCs primarily arose from indoor sources.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationBTEX compounds are often an indicator of combustion emissions and gasoline vapors, such as traffic, gas stations, and industry.
“BTEX compounds are often an indicator of combustion emissions and gasoline vapors, e.g., traffic, gas stations, industry [66, 67].”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFormaldehyde is used in numerous products including paper, fabrics, and synthetic fibers.
“Formaldehyde also is used in numerous products including paper, fabrics and synthetic fibers [62].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFormaldehyde emissions from building materials and furnishings are well recognized.
“Formaldehyde emissions from building materials and furnishings are well recognized [61].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [61] source
May combine two claims.
Study design and conductown dataThe health risk estimates are preliminary or screening level, based on short-term measurements of a small number of hotel workers.
“We present preliminary or screening level estimates of health risks that are attributable to VOC inhalation based on short-term measurements of a small number of hotel workers.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThe lack of elevated personal chloroform among laundry workers may be because they did not remain in the laundry room as their work included collecting unwashed items in all rooms.
“possibly because these workers did not remain in the laundry room as their work included collecting unwashed items in all rooms.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenDue to constraints including hotel manager's decisions, repeated and seasonal measurements were not obtained in one hotel.
“Due to constraints including the hotel manager’s decisions, repeated and seasonal measurements were not obtained in one hotel.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationChloroform is classified as a likely human carcinogen by the US EPA and as possibly carcinogenic to humans by IARC; it is associated with kidney, liver, and bladder tumors.
“Chloroform is classified as a likely human carcinogen by the US EPA [86] and as possibly carcinogenic to humans by the International Agency for Research on Cancer (IARC) [87]; it is associated with kidney, liver and bladder tumors [87, 88].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [86] source
- cites [87]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [88]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Study design and conductown dataA smaller set of formaldehyde measurements limited ability to estimate distributions and analyze personal exposures; formaldehyde measurements may be underestimated due to high LOD (6 μg/m3).
“A smaller set of formaldehyde measurements was obtained, which limited our ability to estimate distributions and analyze personal exposures; also, formaldehyde measurements may be underestimated due to the relatively high LOD (6 μg/m3).”
Quote in the paperNot a substantial claimMay combine two claims.
Study design and conductreasoningThe study had a small sample size that incompletely accounts for temporal and geographical variability; analyses of specific work sites or work groups may be particularly hindered.
“We recognized limitations due to the study’s small sample size, which incompletely accounts for temporal and geographical variability; analyses of specific work sites or work groups (e.g., maintenance workers) may be particularly hindered by this issue.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataThe study did not evaluate occupational risks and hazards other than VOC exposures.
“We did not evaluate occupational risks and hazards other than from VOC exposures; ergonomic and other concerns are also important.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenACR estimates derived from CO2 measurements are approximate, although the decay method can provide robust results.
“The ACR estimates derived from CO2 measurements are approximate, although the decay method can provide robust results.”
Quote in the paperNot a substantial claim
The paper relies on this without support.
Little is known about hotel housekeepers' exposure to chemicals, including VOCs.
“Little is known about their exposure to chemicals, including volatile organic compounds (VOCs).”
“Relatively little has been reported regarding exposures of these workers, particularly to volatile organic compounds (VOCs), the focus of the present work.”
The paper relies on this without support.
Information regarding inhalation exposure of hotel workers is missing.
“but information regarding inhalation exposure of hotel workers is missing.”
The authors state this as an assumption.
The risk calculations assume a 40-hour work week.
“Assuming a 40 hour work week, the non-cancer hazard ratio (HR) and cancer risk (CR) estimates during working years were calculated as:”
The paper relies on this without support.
Hotel housekeepers are a potentially susceptible and vulnerable population.
“Hotel housekeepers are a potentially susceptible and vulnerable population.”
The paper relies on this without support.
The HVAC systems in the rooms were continuously operating during the measurements.
“To our knowledge, HVAC systems in the rooms were continuously operating during the measurements.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Ten target VOC standards are unaccounted for
MinorThe paper says it analyzed 98 target VOCs, but its stated sources of standards cover only 60 target VOCs in mixtures and 28 as neat compounds, totaling 88. The three internal standards are identified separately and do not close the gap.
Reported 98 · recomputed 88
“Samples were analyzed for 98 target VOCs. All standards were purchased from MilliporeSigma (Burlington, Massachusetts, USA) as mixtures (four mixture standards for 60 target VOCs and one mixture for three internal standards) or as neat compounds (28 target VOCs).”
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2000) · doi:10.32614/r.manuals · Cited by 355,706 · see citing works
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808 · cited 1× · see citing works
“, mean) levels of ~20 μg/m3 in US stores, restaurants and residences, and higher levels, ~60 μg/m3, in mobile homes [50].”
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846 · cited 1× · see citing works
“73 74-76 All cleaning products in this study contained terpenes, averaging 13 µ g/mL (40% of TTVOCs); the smoke remover contained 64 µ g/mL.”
Huang, B., Lei, C., Wei, C., & Zeng, G. (2014) · Environment International · doi:10.1016/j.envint.2014.06.013 · Cited by 839 · cited 1× · see citing works
“Chlorinated compounds include relatively non-polar solvents that are also found in cleansing agents [70], as found in several cleaning products in this study (Table S5).”
Formaldehyde in China: Production, consumption, exposure levels, and health effects
Tang, X., Bai, Y., Duong, A., Smith, M. T., Li, L., & Zhang, L. (2009) · Environment International · doi:10.1016/j.envint.2009.06.002 · Cited by 757 · cited 1× · see citing works
“, 60–290 μg/m3 [51], 114 μg/m3 in new hotels [22], 140 μg/m3 in newly furnished rooms, and 10 μg/m3 in older rooms [52].”
Cogliano, V. J., Grosse, Y., Baan, R. A., Straif, K., Secretan, M. B., Ghissassi, F. E., & the Working Group for Volume 88 (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7542 · Cited by 375 · cited 1× · see citing works
“88,89 Formaldehyde is classified as a probable human carcinogen by the US EPA 90 and as a human carcinogen by the IARC 91,92 ; it is associated with nasopharynx, sinonasal, and leukemia cancers.”
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348 · cited 1× · see citing works
“, irritation to eyes, skin and the respiratory system; damage to the liver and kidney; reproductive effects; and carcinogenicity [11, 12].”
Indoor air pollutants in office environments: assessment of comfort, health, and performance.
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 340 · see citing works
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330 · cited 2× · see citing works
“, terpenes) can react with ozone in air to generate secondary pollutants, such as formaldehyde and acetaldehyde, free radicals and ultrafine particles [13] that also pose health risks [14].”
Singer, B. C., Destaillats, H., Hodgson, A. T., & Nazaroff, W. W. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00414.x · Cited by 324 · see citing works
Destaillats, H., Lunden, M. M., Singer, B. C., Coleman, B., Hodgson, A. T., Weschler, C. J., & Nazaroff, W. W. (2006) · Environmental Science & Technology · doi:10.1021/es052198z · Cited by 287 · see citing works
Dry cleaning, some chlorinated solvents and other industrial chemicals.
(1995) · PubMed Central · Cited by 278 · see citing works
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271 · cited 1× · see citing works
“37,38 The CO 2 concentration of replacement air was set to the measured outdoor level (399-404 ppm).”
Self-citationIndoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong
Lee, S. C., Li, W.-M., & Yin Chan, L. (2001) · Science of The Total Environment · doi:10.1016/s0048-9697(01)00765-3 · Cited by 263 · cited 1× · see citing works
“Restaurants had higher levels of BTEX and sometimes chloroform, especially near cooking stoves in dining areas, for example, at Korean barbeque restaurants [54, 55].”
Self-citationWALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C. (2002) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500229 · Cited by 260 · cited 1× · see citing works
“In hotels and many other buildings, ACRs depend on the design and operation of the mechanical systems, infiltration rates (which depend on indoor-outdoor temperature differences and wind speed 80 ), building design, and other factors.”
Golden, R. (2011) · Critical Reviews in Toxicology · doi:10.3109/10408444.2011.573467 · Cited by 201 · see citing works
Influence of temperature on formaldehyde emission parameters of dry building materials
Zhang, Y., Luo, X., Wang, X., Qian, K., & Zhao, R. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.10.081 · Cited by 194 · cited 1× · see citing works
“62 Formaldehyde also is used in numerous products including paper, fabrics, and synthetic fibers.”
Ingestion, inhalation, and dermal exposures to chloroform and trichloroethene from tap water.
Weisel, C. P., & Jo, W. K. (1996) · Environmental Health Perspectives · doi:10.1289/ehp.9610448 · Cited by 177 · cited 1× · see citing works
“A large amount of bleach were used for laundry and room cleaning, suggesting the importance of this source [10, 68] and possibly tap water, which frequently contains chloroform as a disinfection byproduct [69].”
Levels and sources of volatile organic compounds in homes of children with asthma
Chin, J.-Y., Godwin, C., Parker, E., Robins, T., Lewis, T., Harbin, P., & Batterman, S. (2014) · Indoor Air · doi:10.1111/ina.12086 · Cited by 165 · see citing works
Self-citationHalogenated Volatile Organic Compounds from the Use of Chlorine-Bleach-Containing Household Products
Odabasi, M. (2008) · Environmental Science & Technology · doi:10.1021/es702355u · Cited by 159 · cited 2× · see citing works
“A large amount of bleach were used for laundry and room cleaning, suggesting the importance of this source [10, 68] and possibly tap water, which frequently contains chloroform as a disinfection byproduct [69].”
Formaldehyde and chemosensory irritation in humans: A controlled human exposure study
Lang, I., Bruckner, T., & Triebig, G. (2008) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2007.08.012 · Cited by 158 · cited 1× · see citing works
“61,81,82 Calculated HRs fall below one (range: 0.3-0.5), which suggest a low likelihood of adverse effects, although a HR threshold of 0.1 is sometimes used to provide an extra margin of safety.”
InfluentialHuman health risks of formaldehyde indoor levels: An issue of concern
Rovira, J., Roig, N., Nadal, M., Schuhmacher, M., & Domingo, J. L. (2016) · Journal of Environmental Science and Health, Part A · doi:10.1080/10934529.2015.1109411 · Cited by 157 · see citing works
Volatile emissions from common consumer products
Steinemann, A. (2015) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-015-0327-6 · Cited by 156 · see citing works
Yamamoto, N., Shendell, D. G., Winer, A. M., & Zhang, J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00622.x · Cited by 156 · see citing works
Source characterization of BTEX in indoor microenvironments in Hong Kong
Guo, H., Lee, S. C., Li, W. M., & Cao, J. J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00724-0 · Cited by 140 · cited 1× · see citing works
“, traffic, gas stations, industry [66, 67].”
Self-citationFragranced consumer products and undisclosed ingredients
Steinemann, A. C. (2009) · Environmental Impact Assessment Review · doi:10.1016/j.eiar.2008.05.002 · Cited by 139 · cited 1× · see citing works
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Short-term respiratory effects of cleaning exposures in female domestic cleaners
Medina-Ramón, M., Zock, J. P., Kogevinas, M., Sunyer, J., Basagaña, X., Schwartz, J., Burge, P. S., Moore, V., & Antó, J. M. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00085405 · Cited by 138 · cited 1× · see citing works
“15-18 We also note that the full chemical composition of cleaning products generally is not listed on product labels.”
Anderson, S. E., Wells, J., Fedorowicz, A., Butterworth, L. F., Meade, B., & Munson, A. E. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm043 · Cited by 122 · see citing works
Ventilation in public housing: implications for indoor nitrogen dioxide concentrations
Zota, A., Adamkiewicz, G., Levy, J. I., & Spengler, J. D. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00375.x · Cited by 118 · see citing works
Asthma risk, cleaning activities and use of specific cleaning products among Spanish indoor cleaners
Zock, J.-P., Kogevinas, M., Sunyer, J., Almar, E., Muniozguren, N., Payo, F., Sánchez, J. L., & Antó, J. M. (2001) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.590 · Cited by 115 · cited 1× · see citing works
“15-18 We also note that the full chemical composition of cleaning products generally is not listed on product labels.”
Human respiratory uptake of chloroform and haloketones during showering
Xu, X., & Weisel, C. P. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500374 · Cited by 101 · cited 1× · see citing works
“Chloroform was not detected in the laundry products; however, this is a common byproduct of bleach, which is used liberally in hotels [10, 39]; chloroform is also a water disinfection byproduct that is volatilized from tap water, particularly from showers and dishwashers [40, 41].”
(2003) · doi:10.1002/0471125474 · Cited by 100 · see citing works
Volatile Organic Compounds in Small- and Medium-Sized Commercial Buildings in California
Wu, X. (., Apte, M. G., Maddalena, R., & Bennett, D. H. (2011) · Environmental Science & Technology · doi:10.1021/es202132u · Cited by 97 · cited 1× · see citing works
“In offices in California, levels of individual VOCs ranged from non-detect to over 1000 μg/m3 [48, 49].”
Impact of room fragrance products on indoor air quality
Uhde, E., & Schulz, N. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.11.020 · Cited by 90 · cited 1× · see citing works
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Volatile Organic Compounds (VOCs) in Conventional and High Performance School Buildings in the U.S.
Zhong, L., Su, F., & Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14010100 · Cited by 89 · see citing works
Self-citationKopferschmitt-Kubler, M. C., Ameille, J., Popin, E., Calastreng-Crinquand, A., Vervloet, D., Bayeux-Dunglas, M. C., Pauli, G., & members of Observatoire National de Asthmes Professionnels Group (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00102202 · Cited by 88 · see citing works
EPHECT III: Health risk assessment of exposure to household consumer products
Trantallidi, M., Dimitroulopoulou, C., Wolkoff, P., Kephalopoulos, S., & Carrer, P. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.05.123 · Cited by 87 · see citing works
Sources, concentrations, and risks of naphthalene in indoor and outdoor air
Batterman, S., Chin, J.-Y., Jia, C., Godwin, C., Parker, E. A., Robins, T. G., Max, P., & Lewis, T. C. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00760.x · Cited by 87 · see citing works
Self-citationTen questions concerning air fresheners and indoor built environments
Steinemann, A. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.009 · Cited by 84 · see citing works
Excess incidence of asthma among Finnish cleaners employed in different industries
Karjalainen, A., Martikainen, R., Karjalainen, J., Klaukka, T., & Kurppa, K. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00201002 · Cited by 81 · see citing works
Concentrations and emissions of gasoline and other vapors from residential vehicle garages
Batterman, S., Hatzivasilis, G., & Jia, C. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.11.017 · Cited by 76 · cited 1× · see citing works
“Sampling protocols, including tube preparation, transport, storage and analysis, are detailed elsewhere [29, 32, 33].”
Self-citationChloroform Mode of Action: Implications for Cancer Risk Assessment
Golden, R. J., Holm, S. E., Robinson, D. E., Julkunen, P. H., & Reese, E. A. (1997) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.1997.1161 · Cited by 76 · cited 1× · see citing works
“Chloroform is classified as a likely human carcinogen by the US EPA [86] and as possibly carcinogenic to humans by the International Agency for Research on Cancer (IARC) [87]; it is associated with kidney, liver and bladder tumors [87, 88].”
The Impact of a Worker Health Study on Working Conditions
Lee, P. T., & Krause, N. (2002) · Journal of Public Health Policy · doi:10.2307/3343224 · Cited by 75 · cited 1× · see citing works
“Most hotel housekeepers are immigrant women, people of color and contingent workers [2, 3].”
Measured Concentrations of VOCs in Several Non-Residential Microenvironments in the United States
Loh, M. M., Houseman, E. A., Gray, G. M., Levy, J. I., Spengler, J. D., & Bennett, D. H. (2006) · Environmental Science & Technology · doi:10.1021/es060197g · Cited by 71 · cited 2× · see citing works
“Restaurants had higher levels of BTEX and sometimes chloroform, especially near cooking stoves in dining areas, for example, at Korean barbeque restaurants [54, 55].”
Effect of outside air ventilation rate on volatile organic compound concentrations in a call center
Hodgson, A. T., Faulkner, D., Sullivan, D. P., DiBartolomeo, D. L., Russell, M. L., & Fisk, W. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.028 · Cited by 71 · see citing works
A review of air exchange rate models for air pollution exposure assessments
Breen, M. S., Schultz, B. D., Sohn, M. D., Long, T., Langstaff, J., Williams, R., Isaacs, K., Meng, Q. Y., Stallings, C., & Smith, L. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.30 · Cited by 69 · cited 1× · see citing works
“Air change rates (ACRs) were estimated for the break, guest and laundry rooms using CO2 as a “natural” tracer gas and the decay method [37, 38].”
Dermal uptake of chloroform and haloketones during bathing
Xu, X., & Weisel, C. P. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500404 · Cited by 69 · cited 1× · see citing works
“Chloroform was not detected in the laundry products; however, this is a common byproduct of bleach, which is used liberally in hotels [10, 39]; chloroform is also a water disinfection byproduct that is volatilized from tap water, particularly from showers and dishwashers [40, 41].”
Bradman, A., Gaspar, F. W., Castorina, R., Williams, J., Hoang, T., Jenkins, P., McKone, T. E., & Maddalena, R. L. (2016) · Indoor Air · doi:10.1111/ina.12283 · Cited by 69 · see citing works
VOC sources and exposures in nail salons: a pilot study in Michigan, USA
Zhong, L., Batterman, S., & Milando, C. W. (2019) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-018-1353-0 · Cited by 62 · see citing works
Self-citationKumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2014) · Indoor Air · doi:10.1111/ina.12096 · Cited by 61 · see citing works
Volatile pollutants emitted from selected liquid household products
Kwon, K.-D., Jo, W.-K., Lim, H.-J., & Jeong, W.-S. (2008) · Environmental Science and Pollution Research · doi:10.1007/s11356-008-0028-x · Cited by 61 · cited 1× · see citing works
“Cleaning and fragrance products contain many VOCs, such as benzene, chlorobenzene, chloroform, 1,4-dioxane, ethylbenzene, 1,1-dichloroethane, 1,2-dichloropropane, carbon tetrachloride, trichloroethene, bromodichloromethane, 1,2-dichlorobenzene, and 1,3dichlorobenzene [9, 10].”
Du, L., Batterman, S., Godwin, C., Chin, J.-Y., Parker, E. A., Breen, M. S., Brakefield-Caldwell, W., Robins, T. G., & Lewis, T. C. (2012) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph9124639 · Cited by 60 · see citing works
Self-citationOdabasi, M., Elbir, T., Dumanoglu, Y., & Sofuoglu, S. C. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.04.049 · Cited by 57 · cited 4× · see citing works
“Cleaning and fragrance products contain many VOCs, such as benzene, chlorobenzene, chloroform, 1,4-dioxane, ethylbenzene, 1,1-dichloroethane, 1,2-dichloropropane, carbon tetrachloride, trichloroethene, bromodichloromethane, 1,2-dichlorobenzene, and 1,3dichlorobenzene [9, 10].”
Influentialde Groot, A. C., Coz, C. J. L., Lensen, G. J., et al. (2010) · Contact Dermatitis · doi:10.1111/j.1600-0536.2010.01698.x · Cited by 57 · see citing works
Variability of indoor and outdoor VOC measurements: An analysis using variance components
Jia, C., Batterman, S., & Relyea, G. E. (2011) · Environmental Pollution · doi:10.1016/j.envpol.2011.09.024 · Cited by 57 · see citing works
Self-citationThe world at work: hotel cleaners
Hsieh, Y.-C. (., Apostolopoulos, Y., & Sönmez, S. (2013) · Occupational and Environmental Medicine · doi:10.1136/oemed-2012-100986 · Cited by 56 · cited 1× · see citing works
“The nature of the hotel housekeepers’ job tasks, workload and work intensity increase exposure to physical (back injuries, and sprains), chemical (concentrated cleaning products, and fragranced products), biological (blood, body fluids, and microbe), and psychosocial (low respect, and discrimination) hazards [7, 8].”
Indoor air quality in new hotels’ guest rooms of the major world factory region
Chan, W., Lee, S.-C., Chen, Y., Mak, B., Wong, K., Chan, C.-S., Zheng, C., & Guo, X. (2009) · International Journal of Hospitality Management · doi:10.1016/j.ijhm.2008.03.004 · Cited by 55 · see citing works
Su, F.-C., Friesen, M. C., Stefaniak, A. B., Henneberger, P. K., LeBouf, R. F., Stanton, M. L., Liang, X., Humann, M., & Virji, M. A. (2018) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxy055 · Cited by 46 · see citing works
De Groot, A. C., Le Coz, C. J., Lensen, G. J., Flyvholm, M., Maibach, H. I., & Coenraads, P. (2010) · Contact Dermatitis · doi:10.1111/j.1600-0536.2009.01675.x · Cited by 46 · see citing works
De Groot, A. C., & Maibach, H. I. (2010) · Contact Dermatitis · doi:10.1111/j.1600-0536.2009.01581.x · Cited by 40 · cited 1× · see citing works
“64,65 Still, the large amount of bedding and towels used in hotels that contain even low levels of formaldehyde will contribute to housekeeper exposures, although several washings are expected to substantially decrease emissions.”
Stressors, allostatic load, and health outcomes among women hotel housekeepers: A pilot study
Rosemberg, M.-A. S., Li, Y., McConnell, D. S., McCullagh, M. C., & Seng, J. S. (2019) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1563303 · Cited by 38 · cited 1× · see citing works
“26,27 We first asked hotel managers about their interest in participating in this study.”
Self-citationFazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35 · see citing works
Spatial and temporal variability in VOC levels within a commercial retail building
Eklund, B. M., Burkes, S., Morris, P., & Mosconi, L. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00537.x · Cited by 35 · see citing works
Use of Hygiene Protocols to Control the Spread of Viruses in a Hotel
Sifuentes, L. Y., Koenig, D. W., Phillips, R. L., Reynolds, K. A., & Gerba, C. P. (2014) · Food and Environmental Virology · doi:10.1007/s12560-014-9158-0 · Cited by 33 · cited 1× · see citing works
“Chloroform was not detected in the laundry products; however, this is a common byproduct of bleach, which is used liberally in hotels [10, 39]; chloroform is also a water disinfection byproduct that is volatilized from tap water, particularly from showers and dishwashers [40, 41].”
Volatile organic compounds in fourteen U.S. retail stores
Nirlo, E. L., Crain, N., Corsi, R. L., & Siegel, J. A. (2014) · Indoor Air · doi:10.1111/ina.12101 · Cited by 30 · cited 1× · see citing works
“Measurements in 14 US retail stores [53] showed slightly higher levels of formaldehyde (averaging 18 ppb = 22 μg/m3) and BTEX (9.”
Carcinogenicity and Chronic Toxicity in Rats and Mice Exposed to Chloroform by Inhalation
Yamamoto, S., Kasai, T., Matsumoto, M., Nishizawa, T., Arito, H., Nagano, K., & Matsushima, T. (2002) · Journal of Occupational Health · doi:10.1539/joh.44.283 · Cited by 30 · cited 1× · see citing works
“85,86 Chloroform is classified as a likely human carcinogen by the US EPA 87 and as possibly carcinogenic to humans by the International Agency for Research on Cancer (IARC) 88 ; it is associated with kidney, liver, and bladder tumors.”
Lethal complications after poisoning with chloroform — case report and literature review
Lionte, C. (2010) · Human & Experimental Toxicology · doi:10.1177/0960327109357142 · Cited by 27 · cited 1× · see citing works
“At high exposures (not found in this study), chloroform can cause central nervous system effects, respiratory depression, delayed hepatotoxicity [83], kidney and liver damage, and reproductive effects [84, 85].”
Characterisation of Volatile Organic Compounds at Hotels in Southern China
Chan, C. S., Lee, S. C., Chan, W., Ho, K. F., Tian, L., Lai, S. C., Li, Y. S., & Huang, Y. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409458 · Cited by 25 · cited 1× · see citing works
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Quinn, C. L., Demirjian, A., Watkins, L. F., et al. (2015) · PubMed · Cited by 21 · see citing works
Effort-Reward Imbalance and Work Productivity Among Hotel Housekeeping Employees: A Pilot Study
Rosemberg, M.-A. S., & Li, Y. (2018) · Workplace Health & Safety · doi:10.1177/2165079918755803 · Cited by 21 · cited 1× · see citing works
“26,27 We first asked hotel managers about their interest in participating in this study.”
Self-citationThe Effect of Clothing Care Activities on Textile Formaldehyde Content
Novick, R. M., Nelson, M. L., McKinley, M. A., Anderson, G. L., & Keenan, J. J. (2013) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287394.2013.821439 · Cited by 18 · cited 1× · see citing works
“Still, the large amount of bedding and towels used in hotels that contain even low levels of formaldehyde will contribute to housekeeper exposures, although several washings are expected to substantially decrease emissions [65].”
Agency-Hired Hotel Housekeepers
Sanon, M. (2014) · Workplace Health & Safety · doi:10.1177/216507991406200205 · Cited by 16 · see citing works
Williams, A. L., Bates, C. A., Pace, N. D., Leonhard, M. J., Chang, E. T., & DeSesso, J. M. (2018) · Birth Defects Research · doi:10.1002/bdr2.1382 · Cited by 14 · cited 1× · see citing works
“85,86 Chloroform is classified as a likely human carcinogen by the US EPA 87 and as possibly carcinogenic to humans by the International Agency for Research on Cancer (IARC) 88 ; it is associated with kidney, liver, and bladder tumors.”
He, Q., Song, Q., Yan, Y., Wang, Z., Guo, L., & Wang, X. (2016) · Atmosphere · doi:10.3390/atmos7040054 · Cited by 13 · cited 1× · see citing works
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Lee, J. Y., Kim, K., Ryu, S. H., Kim, C. H., & Bae, G.-N. (2018) · Asian Journal of Atmospheric Environment · doi:10.5572/ajae.2018.12.2.127 · Cited by 12 · cited 1× · see citing works
“, traffic, gas stations, industry [66, 67].”
Composition of Gum Turpentine of Coulter Pine.
Mirov, N. T. (1946) · Industrial & Engineering Chemistry · doi:10.1021/ie50436a019 · Cited by 9 · cited 1× · see citing works
“59-61 Formaldehyde emissions from building materials and furnishings are well recognized.”
Gallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011) · Sick Building Syndrome · doi:10.1007/978-3-642-17919-8_16 · Cited by 9 · see citing works
Methods for the determination of metals and inorganic chemicals in environmental samples
Bennett, G. F. (1997) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(97)82806-3 · Cited by 8 · see citing works
Tao, X., Yu, S., Li, K., et al. (2004) · PubMed · Cited by 8 · see citing works
Agency-Hired Hotel Housekeepers: An At-Risk Group for Adverse Health Outcomes
Sanon, M. (2014) · Workplace Health & Safety · doi:10.3928/21650799-20140121-02 · Cited by 7 · see citing works
Formaldehyde Levels in Traditional and Portable Classrooms: A Pilot Investigation.
Ribeiro, I. C., Kowalski, P. J., Callahan, D. B., et al. (2016) · PubMed · Cited by 6 · see citing works
Agency-Hired Hotel Housekeepers: An At-Risk Group for Adverse Health Outcomes
Sanon, M.-A. V. (2014) · Workplace Health & Safety · doi:10.3928/21650799-20140121-07 · Cited by 6 · see citing works
Preventing Workplace Injuries Commonly Sustained by Hotel Guestroom Attendants
DaRos, J. (2020) · Digital Scholarship - UNLV (University of Nevada Reno) · doi:10.34917/2491207 · Cited by 5 · see citing works
Muir, K. (1996) · Journal of Public Health · doi:10.1093/oxfordjournals.pubmed.a024560 · Cited by 3 · see citing works
SAMPLE PREPARATION PROCEDURE FOR SPECTROCHEMICAL DETERMINATION OF TOTAL RECOVERABLE ELEMENTS
(1996) · Methods for the Determination of Metals in Environmental Samples · doi:10.1016/b978-0-8155-1398-8.50008-2
Flagged first, then by citations
Research works printed but not linked: 5
- ASHRAE (Firm), 2016, Standard 55–2013 user's manual: ANSI/ASHRAE standard 55–2013, thermal environmental conditions for human occupancy
- ASTM International, 2020, D1356 Standard Terminology Relating to Sampling and Analysis of Atmospheres
- Stanley WBM, 2012, Contaminants in hotel room exhaust air, Ashrae Trans, 118, 316
- United States. Government Accountability Office, 2010, Formaldehyde in Textiles While Levels in Clothing Generally Appear to be Low, Allergic Contact Dermatitis is a Health Issue for Some People: Report to Congressional Committees
- IARC, Working Group on the Evaluation of Carcinogenic Risks to Humans, International Agency for Research on Cancer, 1999, Some Chemicals that Cause Tumours of the Kidney or Urinary Bladder in Rodents and Some Other Substances, 674
Cited by
Sorted by citations
Oxygen vacancies in the catalyst: Efficient degradation of gaseous pollutants
Zhao, S., Yang, Y., Bi, F., et al. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.140376 · Cited by 247 · see citing works
Duan, C.-S., Liao, H., Wang, K., & Ren, Y. (2022) · Environmental Research · doi:10.1016/j.envres.2022.114386 · Cited by 136 · see citing works
Khoshakhlagh, A. H., Mohammadzadeh, M., Manafi, S. S., et al. (2023) · Environmental Pollution · doi:10.1016/j.envpol.2023.121854 · Cited by 97 · see citing works
A wearable technology solution and research agenda for housekeeper safety and health
Mejia, C., Ciarlante, K. E., & Chheda, K. (2021) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-01-2021-0102 · Cited by 49 · see citing works
Lv, J.-J., Li, X., Shen, Y., et al. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1210136 · Cited by 39 · see citing works
Identifying the Best Practices in Hotel Green Supply Chain Management Strategy: A Global Study
Migdadi, Y. K. A. (2022) · Journal of Quality Assurance in Hospitality & Tourism · doi:10.1080/1528008x.2022.2065657 · Cited by 36 · see citing works
Exposomics as a tool to investigate differences in health and disease by sex and gender
Bucher, M. L., Anderson, F. L., Lai, Y., Dicent, J., Miller, G. W., & Zota, A. R. (2023) · Exposome · doi:10.1093/exposome/osad003 · Cited by 31 · see citing works
Sambiagio, N., Berthet, A., Wild, P. P., Sauvain, J., Auer, R., Schoeni, A., Rodondi, N., Feller, M., Humair, J., Berlin, I., et al. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.158361 · Cited by 31 · see citing works
Qiagedeer, A., Yamagishi, H., Hayashi, S., & Yamamoto, Y. Y. (2021) · ACS Omega · doi:10.1021/acsomega.1c02749 · Cited by 32 · see citing works
Lin, N., Kwarteng, L., Godwin, C., Warner, S. C., Robins, T. G., Arko‐Mensah, J., Fobil, J. N., & Batterman, S. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126353 · Cited by 29 · see citing works
Self-citationJi, W., Wang, Y., Zhao, B., et al. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.135630 · Cited by 29 · see citing works
Jin, S., Zhong, L., Zhang, X., et al. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20105829 · Cited by 25 · see citing works
Dumas, O. (2020) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/aci.0000000000000710 · Cited by 23 · see citing works
Occupational Health and Safety of Immigrant Hotel Housekeepers
Shapoval, V., Sönmez, S., Hsieh, Y.-C. J., & Apostolopoulos, Y. (2022) · Workplace Health & Safety · doi:10.1177/21650799221090712 · Cited by 28 · see citing works
“Several studies on hotel workers’ occupational health—employing both ethnographic fieldwork and survey research—have documented that the workers’ psychological well-being is often jeopardized by the stress of constant time pressures to finish assigned rooms (Hsieh et al., 2016, 2017; Lin et al., 2021).”
BackgroundLi, J., Cheng, T., Ma, X., Wu, H., & Yang, L. (2022) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2022.128604 · Cited by 21 · see citing works
Volatile Organic Compound Emissions from Disinfectant Usage in the Home and Office
Bruchard, W., Bajracharya, A., & Johnston, N. A. C. (2023) · Environmental Health Perspectives · doi:10.1289/ehp11916 · Cited by 15 · see citing works
Sweet, N. M., Lunderberg, D. M., Molinier, B., Pfannerstill, E. Y., Katz, E. F., Misztal, P. K., Liu, Y. J., Arata, C. M., Kristensen, K. V., Tian, Y., et al. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c11274 · Cited by 15 · see citing works
Surface Microbial Contamination and Air Quality before and after Regular Cleaning Procedures
Mohammed, M. O. A. (2023) · Atmosphere · doi:10.3390/atmos14020352 · Cited by 13 · see citing works
Indoor air and respiratory health: Volatile organic compounds and cleaning products
Casas, L., Dumas, O., & Moual, N. L. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85419-1.00002-5 · Cited by 14 · see citing works
Be alert for vapor intrusion of 1,4-dioxane from contaminated groundwater
Lin, N., Zhong, L., Godwin, C., et al. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.153713 · Cited by 11 · see citing works
Self-citationExhaled breath analysis applications for evaluating occupational and environmental exposures
Bakali, U., Killawala, C., Monteagudo, E., Dikici, E., Deo, S. K., & Daunert, S. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117787 · Cited by 13 · see citing works
Research on Hotel Management Based on Internet of Things and Big Data Analysis
Jiang, H. (2022) · International Journal of Reliability, Quality and Safety Engineering · doi:10.1142/s0218539322400046 · Cited by 10 · see citing works
Li, C., Wang, H., Bai, L. M., Chi, Y., Bai, L. M., Li, Z., & Tham, K. W. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113115 · Cited by 9 · see citing works
Seo, J. H., Kim, P.-G., Choi, Y., et al. (2025) · Atmospheric Environment · doi:10.1016/j.atmosenv.2025.121235 · Cited by 9 · see citing works
Chloroform—An Emerging Pollutant in the Air
Sekar, A., Varghese, G. K., & Varma, M. K. R. (2021) · Energy, environment, and sustainability · doi:10.1007/978-981-16-8367-1_6 · Cited by 17 · see citing works
Nored, A. W., Fu, X., Qi, R., Batbaatar, N., & Jia, C. (2024) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph21111464 · Cited by 7 · see citing works
“In the only previous US study, the cancer risk was 4.5 × 10 − 6 among hotel workers, if applying the same set of VOCs and exposure factors as our study [52].”
InfluentialLin, N., Yun, X., Zhang, Y., Wu, Y., Du, W., & Batterman, S. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.5c05147 · Cited by 8 · see citing works
Self-citationBTEX pollution and health effects in a metro system
Wang, H., Deng, M., Wang, M., et al. (2025) · Building Simulation · doi:10.1007/s12273-025-1291-1 · Cited by 6 · see citing works
“BTEX are pollutants with potential adverse effects on human health, primarily originating from vehicle emissions, decorative materials, industrial activities, and evaporative losses of fuels (Kermani et al. 2021; Lin et al. 2021).”
Astuti, R. D. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-16090-5.00001-5 · Cited by 6 · see citing works
Attached Smoking Room Is a Source of PM2.5 in Adjacent Nonsmoking Areas
Du, W., Wang, J., Chen, Y., Pan, B., Shen, G., & Lin, N. (2023) · Indoor Air · doi:10.1155/2023/7290742 · Cited by 6 · see citing works
Self-citationdos Reis, A. S., Dias, M. F., & Tavares, A. (2022) · Lecture notes in civil engineering · doi:10.1007/978-3-030-96202-9 · Cited by 5 · see citing works
Jung, Y., Kim, Y., Seol, H.-S., Lee, J., & Kwon, J. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18105334 · Cited by 5 · see citing works
Mai, J.-L., Yang, Y., Zeng, Y., et al. (2025) · Environmental Research · doi:10.1016/j.envres.2025.122641 · Cited by 4 · see citing works
Lin, N., Li, Z., Ding, N., et al. (2025) · Environmental Health Perspectives · doi:10.1289/ehp15418 · Cited by 4 · see citing works
Self-citationZhang, M., Li, Y., Zhang, X., Hu, J. M., Lv, L.-S., An, N., Liu, Z., Rao, J., Zhou, C., & Liu, X. (2025) · Indoor Air · doi:10.1155/ina/3747936 · Cited by 4 · see citing works
“Though less frequent, such elevated values suggest the presence of subgroups with high exposure, possibly due to extended duration in poorly ventilated spaces or rooms with recent renovations, consistent with prior research on occupational hotel exposures [56, 57].”
Yijia, G., Zhu, L., Zhang, L., Tang, X., Li, X., Ge, Y., Li, F., Yang, J., Lu, S., Chen, J., et al. (2024) · Toxics · doi:10.3390/toxics12090634 · Cited by 6 · see citing works
“Regarding occupational health, exposure to VOCs poses substantial risks to workers in relevant industries [15,16].”
BackgroundHotel housekeepers and occupational health: experiences and perceived risks
Chela-Àlvarez, X., Bulilete, O., Garcia-Illan, E., et al. (2022) · Annals of Occupational and Environmental Medicine · doi:10.35371/aoem.2022.34.e29 · Cited by 4 · see citing works
Wang, H., Cui, Z., Wang, M., & Li, C. (2025) · Indoor and Built Environment · doi:10.1177/1420326x251320533 · Cited by 3 · see citing works
Cancer-Specific Mortality Odds Ratios in the Food, Accommodation, and Beverage Activities in Italy
Gariazzo, C., Massari, S., Consonni, D., et al. (2024) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000003114 · Cited by 3 · see citing works
“6 Epidemiological studies in this sector were carried out for particular type of workers such cookers, chefs and waiters, 7 – 9 hotel housekeepers, 6 and dry-cleaning workers.”
BackgroundInfluentialCleaning in Times of Pandemic: Perceptions of COVID-19 Risks among Workers in Facility Services
Dias, I., Lopes, A., Azevedo, J., et al. (2022) · Social Sciences · doi:10.3390/socsci11070276 · Cited by 3 · see citing works
Zhao, X. Q., Ding, H., Qin, J. G., et al. (2024) · Toxics · doi:10.3390/toxics12110772 · Cited by 2 · see citing works
dos Reis, A. S., Dias, M. F., & Tavares, A. (2022) · Lecture notes in civil engineering · doi:10.1007/978-3-030-96202-9_20 · Cited by 2 · see citing works
Shehata, A. E., & Selem, K. M. (2021) · مجلة کلية السياحة والفنادق جامعة المنصورة · doi:10.21608/mkaf.2021.217651 · Cited by 2 · see citing works
“The presence of baskets for biological waste and the use of masks equipped with a filter to purify the air (Lin et al., 2021).”
BackgroundInfluentialMorphometric Evaluation of the Recurrent Laryngeal Nerve of Wistar Rats Exposed to Pesticides
Macedo, M. B., Cunha, E. O., dos Reis, A., et al. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.09.028 · Cited by 2 · see citing works
Devetter, F., Galey, L., Prunier‐Poulmaire, S., & Valentin, J. (2026) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2026.103941 · Cited by 1 · see citing works
Ohira, C., Tomita, K., Ota, Y., et al. (2026) · Toxicological Sciences · doi:10.1093/toxsci/kfag009 · Cited by 1 · see citing works
Liang, W., Yu, X., & Yang, X. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.114004 · Cited by 2 · see citing works
Vilela, L., Blom, A., Eden, G. R., Tinnerberg, H., Farbrot, A., Julander, A., & Schenk, L. (2025) · ACS Chemical Health & Safety · doi:10.1021/acs.chas.5c00088 · Cited by 1 · see citing works
NEUTRALIZE BACTERIAL ACTIVITY WITH ANATOMICAL EMBALMING SOLUTIONS
Aditya, D. M. N., Wicaksono, A. S., Afandi, A., et al. (2022) · Jurnal Riset Kesehatan · doi:10.31983/jrk.v11i2.9234 · Cited by 1 · see citing works
“According to previous studies, the level of exposure to formaldehyde should be less than 0.614 mg/m3 (Lin et al., 2021).”
InfluentialSiaw, G. A. (2022) · European Journal of Health Sciences · doi:10.47672/ejhs.1215 · Cited by 1 · see citing works
“In like manner, Lin et al. (2021) reported a negative relationship between training and health and safety practices.”
BackgroundResultHotel housekeepers and occupational health: experiences and perceived risksPreprint
Chela-Àlvarez, X., Bulilete, O., Garcia-Illan, E., et al. (2022) · Research Square · doi:10.21203/rs.3.rs-1227844/v2 · Cited by 1 · see citing works
Hotel Housekeepers and Occupational Health: Experiences and Perceived RisksPreprint
Chela-Àlvarez, X., Bulilete, O., Garcia-Illan, E., et al. (2022) · Research Square · doi:10.21203/rs.3.rs-1227844/v1 · Cited by 1 · see citing works
Lee, M., Jeong, K., Kim, K., Cho, J., Kang, D. R., Sohn, M. H., Lee, Y., & Kim, C. (2026) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-026-00965-5
Salana, S., Friedman, A. M., Austin, J., Shrestha, P., Kurmi, K., Washeem, M., & Wu, C. (2026) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2026.141319 · Cited by 1 · see citing works
Assessing Volatile Organic Compounds (VOCs) in a laboratory and office building environment
García-González, H., Lopez-Pola, M. T., Rodríguez, R., et al. (2025) · Air Quality Atmosphere & Health · doi:10.1007/s11869-025-01835-z
“Strategies include the use of low-emission building materials, VOC-free maintenance products, and air purification systems (Goodman et al. 2018; Lin et al. 2021; Zhang et al. 2022).”
Household cleaning agents impact on pediatric asthma: a systematic review and meta-analysis
Arif, M. I., Wang, Z. Y., & Ru, L. (2025) · International Journal of Environmental Health Research · doi:10.1080/09603123.2025.2467820
“They can react with ozone and form secondary pollutants such as formaldehyde, which is an irritant to the respiratory system and can increase the severity of pediatric asthma (Robroeks et al. 2013; Nurmatov et al. 2015; David and Niculescu 2021; Lin et al. 2021).”
Job quality and health conditions in the hotel industry: the case of housekeeping workers
Gaspani, F., & Recchi, S. (2024) · International Review of Sociology · doi:10.1080/03906701.2024.2364175
“Contact to chemicals present in cleaning products is another health concern for hotel housekeepers (Lin et al., 2021).”
BackgroundEpidemiological aspects of indoor air pollution
Kallawicha, K., Wongsasuluk, P., Chao, H. J., et al. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-16090-5.00002-7
Análise da influência de gênero nos papéis na governança hoteleira
da Silva, J. V. S., & BARROS, L. C. F. M. (2023) · Revista Hospitalidade · doi:10.29147/revhosp.v20.1099
- Authors
- Lin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Batterman, Stuart
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2020-08-24
- Volume
- 31
- Issue
- 1
- Pages
- 26-39
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- PMC
- PMC8020495
- OpenAlex
- W3038768817
- Semantic Scholar
- 0ec65021fc6c6ca395bb84634c4184b85e6b8a26
- Cited by
- 59
- References
- 85
- Citations by year
- 2026: 4 · 2025: 13 · 2024: 9 · 2023: 8 · 2022: 17 · 2021: 7 · 2020: 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- University of Michigan Library
- Funders
- National Institute of Environmental Health Sciences (P30ES017885)
- Centers for Disease Control and Prevention (T42 OH008455)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational exposure and asthma
- Keywords
- volatile organic compounds, hotel housekeepers, occupational exposure, indoor air quality, cleaning agents, formaldehyde, chloroform, alkanes, lifetime cancer risk, ventilation rate, air exchange rate, disinfection by-products, laundry room, personal sampling, health risk assessment
- MeSH terms
- Air Pollutants, Air Pollutants, Occupational, Formaldehyde, Humans, Ventilation, Occupational Exposure, Air Pollution, Indoor, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read under definition version 3 (extract-v3) on 2026-09-28.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-09-28.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review