The occurrence, induction, specificity and potential effect of antibodies against poly(ethylene glycol)
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Specific antibodies against poly(ethylene glycol) (anti-PEG) were induced in animals following exposure to PEG-conjugated proteins and particles, resulting in rapid clearance of PEG-conjugated agents. In humans, induction of anti-PEG was observed following exposure to a PEG-conjugated drug, and pre-existing anti-PEG was identified in over 25% the healthy population. In clinical studies, the presence of anti-PEG was strongly associated with rapid clearance of PEG-asparaginase and PEG-uricase. PEGylation of therapeutic agents will continue to be of significant value in medicine to reduce immunogenicity, antigenicity and toxicity as well as markedly reducing renal clearance, while maintaining drug efficacy. It is important to recognize that PEG itself may possess antigenic and immunogenic properties. Further comprehensive studies are warranted to fully elucidate the effect of anti-PEG on PEG-conjugated agents and if confirmed in a prospective trial, patients should be screened and monitored for anti-PEG, and strategies developed to overcome the potential negative effect of anti-PEG on drug clearance to improve the effectiveness of therapy. These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Armstrong, J. K., Hempel, G., Koling, S., Chan, L. S., Fisher, T., Meiselman, H. J., & Garratty, G. (2007) · Cancer · doi:10.1002/cncr.22739 · Cited by 699
Self-citationPEGylated liposomes elicit an anti-PEG IgM response in a T cell-independent manner
Ishida, T., Wang, X., Shimizu, T., Nawata, K., & Kiwada, H. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.05.015 · Cited by 382
Ganson, N. J., Kelly, S. J., Scarlett, E., Sundy, J. S., & Hershfield, M. S. (2005) · Arthritis Research & Therapy · doi:10.1186/ar1861 · Cited by 350
Microparticles as vaccine adjuvants and delivery systems
O’Hagan, D. T., & Singh, M. (2003) · Expert Review of Vaccines · doi:10.1586/14760584.2.2.269 · Cited by 214
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
Kozma, G. T., Shimizu, T., Ishida, T., & Szebeni, J. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.024 · Cited by 696
Hoang Thi, T. T., Pilkington, E. H., Nguyen, D. H., Lee, J. S., Park, K. D., & Truong, N. P. (2020) · Polymers · doi:10.3390/polym12020298 · Cited by 668
“3% of allergic patients contained anti-PEG antibodies [52].”
BackgroundInfluentialAnti‐ PEG immunity: emergence, characteristics, and unaddressed questions
Yang, Q., & Lai, S. K. (2015) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1339 · Cited by 593
Garay, R. P., El-Gewely, R., Armstrong, J. K., Garratty, G., & Richette, P. (2012) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2012.720969 · Cited by 587
Self-citation
Metadata
- Authors
- Armstrong, J. K.
- Venue
- PEGylated Protein Drugs: Basic Science and Clinical Applications
- Publisher
- Birkhäuser Basel
- Published
- 2009
- Pages
- 147-168
- OpenAlex
- W2255928367
- Cited by
- 72
- References
- 4
- FWCI
- 4.28
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The occurrence, induction, specificity and potential effect of antibodies against poly(ethylene glycol). https://app.cochat.ai/papers/10.1007/978-3-7643-8679-5_9
- The paper
- Armstrong, J. K. (2009). The occurrence, induction, specificity and potential effect of antibodies against poly(ethylene glycol). PEGylated Protein Drugs: Basic Science and Clinical Applications. https://doi.org/10.1007/978-3-7643-8679-5_9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.