Cited by 23Tissue Engineering and Regenerative MedicineBone Tissue Engineering MaterialsPolymer Surface Interaction Studies

In Vivo Evaluation of the Biocompatibility of Biomaterial Device

Frazão, L. P., Vieira de Castro, J., Neves, Nuno M.·2020·Advances in Experimental Medicine and Biology

Abstract

Biomaterials are widely used to produce devices for regenerative medicine. After its implantation, an interaction between the host immune system and the implanted biomaterial occurs, leading to biomaterial-specific cellular and tissue responses. These responses may include inflammatory, wound healing responses, immunological and foreign-body reactions, and even fibrous encapsulation of the implanted biomaterial device. In fact, the cellular and molecular events that regulate the success of the implant and tissue regeneration are played at the interface between the foreign body and the host inflammation, determined by innate and adaptive immune responses. This chapter focuses on host responses that must be taken into consideration in determining the biocompatibility of biomaterial devices when implanted in vivo of animal models.

Integrity signals

Registry

Crossref · 10.1007/978-981-15-3262-7_8

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Both in vitro and in vivo experiments show that PLCL maintains good histocompatibility after implantation and usually only triggers a mild, acute local inflammatory response that is self-limiting within a short period.

    “Both in vitro and in vivo experiments show that PLCL maintains good histocompatibility after implantation, usually only triggers a mild, acute local inflammatory response, which is part of the normal wound healing process and is self-limiting within a short period of time [31, 32].”
  • PLCL materials usually do not trigger severe immune responses or chronic inflammatory responses when degraded in vivo.

    “Therefore, PLCL materials usually do not trigger severe immune responses or chronic inflammatory responses when degraded in vivo.”

The citation lists haven’t been fetched yet

References 123 · Cited by 23

Authors
Frazão, L. P., Vieira de Castro, J., & Neves, N. M.
Affiliations
3B's Research Group (PT)
Venue
Advances in Experimental Medicine and Biology
Published
2020
Volume
1250
Pages
109-124
ISSN
  • 0065-2598 (ISSN-L)
  • 2214-8019
OpenAlex
W3039701765
Cited by
23
References
123
Citations by year
2026: 3 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 5
FWCI
23.12
Type
book chapter
Language
en
Open access
closed
Locations
  • Advances in experimental medicine and biology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
Keywords
biomaterial biocompatibility, host immune response, foreign body reaction, fibrous encapsulation, inflammation, wound healing, innate and adaptive immunity, tissue regeneration, animal models
MeSH terms
Animals, Biocompatible Materials, Foreign-Body Reaction, Immunity, Cellular, Inflammation, Prostheses and Implants, Models, Animal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review