Study of heat exposure in the work environment in Jeddah
Abstract
The present work was conducted to define the magnitude of the problem of heat exposure in Jeddah and the role of both the climatic and the industrial factors on the total heat load. Indoor heat exposure was studied in an industrial complex of 5 plants for cables' manufacturing. Outdoor heat exposure was studied in shaded and unshaded operations in Jeddah Islamic Port (JIP). The heat exposure parameters, including air temperature (Ta), wet bulb temperature (Tw), and globe temperature (Tg), as well as the wet bulb globe temperature (WBGT) heat stress index, the relative humidity and the air velocity, were assessed at representative locations. Results of the study indicated that: (a) the levels of heat exposure exceeded the TLV in mostly all the work areas where no air-conditioning is provided. (b) the ambient heat is the factor contributing most to the heat load both in summer and in winter. (c) the radiant heat from furnaces and hot metal rolling and milling adds more heat load to the work environment in specific operations. An outline of a control strategy has been suggested, emphasizing evaporative engineering heat control, work and hygienic practices and auxiliary cooling clothing.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The escalation and persistence of hot weather during the summer currently poses a significant threat to the health and safety of the working population in Saudi Arabia.
“The escalation and persistence of hot weather during the summer currently poses a significant threat to the health and safety of the working population in SA (Jefri et al., 1990; Noweir et al., 1996; Noweir and Bafail, 2008).”
From Assessment of Heat Stress Exposure among Construction Workers in the Hot Desert Climate of Saudi Arabia (2019) · cites this paper as Noweir et al., 1996
Cites
The stress of hot environments.
Dm, K. (1972) · PubMed · Cited by 338 · see citing works
Heat Stress and Heat Disorders
(1964) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1964.tb115733.x · Cited by 236 · see citing works
Protective clothing and heat stress
Holmér, I. (1995) · Ergonomics · doi:10.1080/00140139508925093 · Cited by 128 · see citing works
Industrial environment: its evaluation and control
Amdur, M. O., Anticaglia, J. R., Barnes, E. C., Belding, H. S., & Bird, F. (1973) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 120 · see citing works
THE INDUSTRIAL ENVIRONMENT—ITS EVALUATION AND CONTROL
Cook, W. A. (1959) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.49.10.1419-b · Cited by 63 · see citing works
Heat Stress and Heat Disorders
Burch, G. E. (1964) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1964.13.775 · Cited by 42 · see citing works
Testing climate indices in the field
Peters, H. “. (1995) · Ergonomics · doi:10.1080/00140139508925087 · Cited by 9 · see citing works
Flagged first, then by citations
1 of the 8 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Al-Bouwarthan, M., Quinn, M. M., Kriebel, D., & Wegman, D. H. (2019) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxz033 · Cited by 144 · see citing works
Cao, Z., Wu, Z., Li, S., Guo, G., Song, S., Deng, Y., Ma, W., Sun, H., & Guan, W. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109813 · Cited by 33 · see citing works
Noweir, M. H., & Bafail, A. O. (2007) · Environmental Monitoring and Assessment · doi:10.1007/s10661-007-0019-2 · Cited by 18 · see citing works
Self-citationButt, M. S., Kuklane, K., Saleem, J., Zakar, R., Bukhari, G. M. J., & Ishaq, M. (2021) · Avicenna · doi:10.5339/avi.2022.5 · Cited by 8 · see citing works
Assessment of Outdoor Workers Perception Working in Extreme Hot Climate
Moda, H. M., & Alshahrani, A. (2018) · Climate change management · doi:10.1007/978-3-319-70479-1_11 · Cited by 8 · see citing works
Buqammaz, M., Almatrouk, J., Kile, M. L., & Kincl, L. D. (2026) · Current Environmental Health Reports · doi:10.1007/s40572-026-00525-x · Cited by 2 · see citing works
Butt, M. S. (2012) · Lund University Publications Student Papers (Lund University) · Cited by 2 · see citing works
Facteurs d’ambiance dans l’industrie textile en République Démocratique du Congo: état de lieu
KITRONZA, P. L., & Mairiaux, P. (2016) · Pan African Medical Journal · doi:10.11604/pamj.2016.25.44.6479 · Cited by 1 · see citing works
- Authors
- Noweir, M. H., Moreb, A. A., & Bafail, A. O.
- Affiliations
- King Abdulaziz University (SA)
- Venue
- Environmental Monitoring and Assessment
- Published
- 1996-05
- Volume
- 40
- Issue
- 3
- Pages
- 225-237
- ISSN
- 0167-6369 (ISSN-L)
- 1573-2959
- OpenAlex
- W2054411061
- Cited by
- 8
- References
- 8
- Citations by year
- 2026: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2016: 1 · 2012: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Environmental Monitoring and Assessment (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety Management
- Keywords
- heat exposure, occupational heat stress, work environment, Jeddah, wet bulb globe temperature, air temperature, wet-bulb temperature, globe temperature, thermal radiation, evaporative cooling, heat load control, thermal comfort
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review