The DOI matches its Crossref record.
Oxygen uptake as related to work rate increment during cycle ergometer exercise
Open accessAbstract
SummaryWe postulated that the commonly observed constant linear relationship between $$\dot V_{{\text{O}}_{\text{2}} }$$ and work rate during cycle ergometry to exhaustion is fortuitous and not due to an unchanging cost of external work. Therefore we measured $$\dot V_{{\text{O}}_{\text{2}} }$$ continuously in 10 healthy men during such exercise while varying the rate of work incrementation and analyzed by linear regression techniques the relationship between $$\dot V_{{\text{O}}_{\text{2}} }$$ and work rate (Δ $$\dot V_{{\text{O}}_{\text{2}} }$$ / Δwr). After excluding the first and last portions of each test we found the mean ±SD of the δ $$\dot V_{{\text{O}}_{\text{2}} }$$ / Δwr in ml · min−1· W−1 to be 11.2±0.15, 10.2±0.16, and 8.8±0.15 for the 15, 30, and 60 W·min−1 tests, respectively, expressed as ml·J−1 the values were 0.187±0.0025, 0.170±0.0027 and 0.147±0.0025. The slopes of the lower halves of the 15 and 30 W·min−1 tests were 9.9±0.2 ml·min−1·W−1 similar to the values for aerobic work reported by others. However the upper halves of the 15, 30, and 60 W·min−1 tests demonstrated significant differences: 12.4±0.36 vs 10.5±0.31 vs 8.7±0.23 ml·min−1·W−1 respectively. We postulate that these systematic differences are due to two opposing influences: 1) the fraction of energy from anaerobic sources is larger in the brief 60 W·min−1 tests and 2) the increased energy requirement per W of heavy work is evident especially in the long 15 W·min−1 tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Levett, D. Z. H., Jack, S., Swart, M., Carlisle, J., Wilson, J., Snowden, C., Riley, M., Danjoux, G., Ward, S. A., Older, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.020 · Cited by 466
Özyener, F., Rossiter, H. B., Ward, S. A., & Whipp, B. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00891.x · Cited by 459
Metadata
- Authors
- Hansen, J. E., Casaburi, R., Cooper, D. M., & Wasserman, K.
- Venue
- European Journal of Applied Physiology and Occupational Physiology
- Published
- 1988
- Volume
- 57
- Issue
- 2
- Pages
- 140-145
- ISSN
- 0020-9376 (ISSN-L)
- 0301-5548
- 1439-6327
- OpenAlex
- W1976858529
- Cited by
- 213
- References
- 0
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen uptake as related to work rate increment during cycle ergometer exercise. https://app.cochat.ai/papers/10.1007/bf00640653
- The paper
- Hansen, J. E., Casaburi, R., Cooper, D. M., & Wasserman, K. (1988). Oxygen uptake as related to work rate increment during cycle ergometer exercise. European Journal of Applied Physiology and Occupational Physiology. https://doi.org/10.1007/bf00640653
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.