Cited by 81Polymer Foaming and CompositesTissue Engineering and Regenerative Medicinebiodegradable polymer synthesis and properties

The DOI matches its Crossref record.

Use of porous biodegradable polymer implants in meniscus reconstruction. 1) Preparation of porous biodegradable polyurethanes for the reconstruction of meniscus lesions

Overview

Integrity signals

Registry

Crossref · 10.1007/bf01410672

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The same degradable polyurethanes based on LDI, 2,2,4-triethylhexamethylene diisocyanate and polyester/copolyester polyols had low tensile strengths (5.8 to 8.1 MPa).

    “The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”

    From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as De Groot et al. (1990)

  • Degradable polyurethanes based on LDI, 2,2,4-triethylhexamethylene diisocyanate and polyester/copolyester polyols had elongations at break as high as 780%.

    “The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”

    From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as De Groot et al. (1990)

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 25

  1. Ghosh P, Taylor TKF (1987) Clinical Orthopeadics and Related Research 224:52?63
  2. Ricklin P, Ruttiman A, Del Buono MS (1971) Meniscus Lesions. Georg Thieme Verlag, Stuttgart, pp 7?9
  3. Veth RPH (1978) ?On the results of meniscetomy of the knee?, Thesis, University of Groningen, The Netherlands
  4. J�rgensen U, Sonne-Holm S, Lauridsen F, Rosenklint A (1987) J of Bone and Joint Surgery 69-B1(1):80?83 · DOI
  5. King D (1936) J Bone Joint Surg 18-A:333
  6. Chadially FN, Wedge JH, van Lalende JMA (1986) J Bone Joint Surg 68-B:106 · DOI
  7. Webber JR, Harris HG, Hough Jr AJ (1985) J Orthop Res 3:36 · DOI
  8. Leenslag JW, Pennings AJ, Veth RPH, Nielsen HKL, Jansen HWB (1984) Macromol Chem Rapid Commun 5:815?821 · DOI
  9. Leenslag JW (1987) Poly(L-lactide) and its biomedical applications. Thesis University of Groningen, The Netherlands
  10. Elema HA, de Groot JH, Nijenhuis AJ, Pennings AJ, Veth RPH, Jansen HWB (part 2, this journal)
  11. Caplan AI (1984) Sci Am 4:82
  12. Leenslag JW, Kroes MT, Pennings AJ, van der Lei B (1988) New Polymeric Materials 1:111
  13. Bruin P, Veenstra GJ, Nijenhuis AJ, Pennings AJ (1988) Makromol Chem Rapid Commun 9:589 · DOI · Paper page
  14. Gogolewski S, Pennings AJ (1982) Makromol Chem Rapid Commun 3:839 · DOI · Paper page
  15. Leenslag JW, Nijenhuis AJ, Pennings AJ, Veth RPH, Nielsen HKL, Jansen HWB (1986). Proceedings of the Noordwijkerhout, The Netherlands, pp 10/1?10/9
  16. Saunders JH, Frisch KC (1964) Polyurethanes chemistry and technology, part 2. Interscience, New York, pp 4?7
  17. Frisch KC, Saunders JH (1972) Plastic foams. Marcel Dekker, New York, pp 60?64
  18. Smith P (1976) Thesis University of Groningen, The Netherlands
  19. Hikmet RM, Callister S, Keller A (1988) Polymer 29:1378 · DOI
  20. Coudeville A, Eyharts P, Perinne JP, Rey L, Rouillard R (1981) J Vac Sci Technol 3:18
  21. Aubert JH, Clough RL (1985) Polymer 26:2047 · DOI
  22. Szycher M, Porier VL, Dempsey DJ (1983) J Elastomers Plast 15:81 · DOI
  23. Rusch KC (1967) J Appl Polym Sci 13:2297 · DOI
  24. Doherty DJ, Hurd R, Lester GR (1962) Chem and Ind 30:1340
  25. Gibson LJ, Ashby MF (1988) Cellular Solids, structure and properties. Pergamon Press, New York, pp 122?153

Cited by

Sorted by citations

  • Biodegradable synthetic polymers for tissue engineering

    CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765

    “These polymers have been used as sutures (Cutright et al., 1971) plates and fixtures for fracture fixation devices (Mayer and Hollinger, 1995) and scaffolds for cell transplantation (Thomson et al. 1995b).”
    Method

Metadata

Authors
de Groot, J. H., Nijenhuis, A. J., Bruin, P., Pennings, A. J., Veth, R. P. H., Klompmaker, J., & Jansen, H. W. B.
Affiliations
  • University Medical Center Groningen (NL)
  • University of Groningen (NL)
Venue
Colloid and Polymer Science
Published
1990-12
Volume
268
Issue
12
Pages
1073-1081
ISSN
  • 0303-402X (ISSN-L)
  • 1435-1536
OpenAlex
W2166556161
Cited by
81
References
0
Citations by year
2026: 1 · 2025: 1 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 3 · 2014: 4 · 2013: 2 · 2012: 3
FWCI
2.04
Type
journal article
Language
en
Open access
closed
Locations
  • Colloid & Polymer Science (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer Foaming and Composites
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
meniscus reconstruction, polyurethane foam, in situ polymerization, Estane, compressive stress-strain behavior, meniscus lesions, biodegradable implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review