CoChat

Nonlinear analysis of flow pulses and shock waves in arteries: Part I: Derivation and properties of mathematical model

Anliker, Max, Rockwell, Robert L., Ogden, Eric · 1971 · Zeitschrift für angewandte Mathematik und Physik ZAMP

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf01591407

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 11

  1. P. A. Peronneau andF. Leger,Doppler Ultrasonic Pulsed Blood Flowmeter, Proc. of the 8th Internat. Conf. on Medical and Biological Engineering, Chicago, Illinois, 1969.
  2. D. W. Baker andD. E. Strandness,Instrumentation for the Early Detection of Arterial Occlusive Disease, Proc. of the 8th Internat. Conf. on Medical and Biological Engineering, Chicago, Illinois, 1969.
  3. R. Skalak,Wave Propagation in Blood Flow, In:Biomechanics Symposium, edited byY. C. Fung, New York, ASME, Appl. Mech. Div., 1966, p. 20–46.
  4. G. Rudinger,Review of Current Mathematical Methods for the Analysis of Blood Flow, In:Biomedical Fluid Mechanics Symposium, New York, ASME, 1966, p. 1–33.
  5. M. F. O'Rourke,Pressure and Flow in Arteries, M. D. Thesis, University of Sydney, 1965.
  6. M. Lister,The Numerical Solution of Hyperbolic Differential Equations by the Method of Characteristics, In:Mathematics for Digital Computers (John Wiley and Sons, New York 1960).
  7. R. T. Jones,Simple Correction of the Windkessel Theory for the Dynamic Impedance of the Aorta, Proc. of the 8th Internat. Conf. on Medical and Biological Engineering, Chicago, Illinois, 1969.
  8. W. W. Nichols, J. E. Webster andD. A. McDonald,Pulse Wave Velocity in the Ascending Aorta of the Dog, Amer. Physiol. Soc. Proc., Davis, California, 1969.
  9. D. A. McDonald,Frequency Dependence of Vascular Impedance, In:Pulsatile Blood Flow, edited byE. O. Attinger (McGraw-Hill Book, Co., New York 1964), p. 115–133.
  10. C. K. Friedberg,Diseases of the Heart (W. B. Saunders Co., Philadelphia 1955).
  11. D. A. McDonald, W. W. Nichols andN. T. Kouchoukos,Methods for Monitoring Cardiac Output, Proc. of the Annual Conf. on Engineering in Medicine and Biology, Houston, Texas, 1968.

Cited by

See all 202

Metadata

Authors
Anliker, M., Rockwell, R. L., & Ogden, E.
Affiliations
  • Stanford University (US)
  • Ames Research Center (US)
Venue
Zeitschrift für angewandte Mathematik und Physik ZAMP
Published
1971-03
Volume
22
Issue
2
Pages
217-246
ISSN
  • 0044-2275 (ISSN-L)
  • 1420-9039
OpenAlex
W3162721712
Cited by
202
References
27
Citations by year
2026: 3 · 2025: 4 · 2024: 2 · 2023: 4 · 2022: 2 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 7 · 2014: 4 · 2013: 2 · 2012: 2
FWCI
5.49
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
Zeitschrift für angewandte Mathematik und Physik (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Physical Sciences › Engineering › Computational Mechanics › Fluid dynamics and aerodynamics studies
Keywords
arterial pulse, shock waves, aorta, nonlinear wave propagation, method of characteristics, dicrotic wave, wave reflection, arterial compliance, systemic vascular resistance, arterial geometry, incompressible flow

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.