The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image analysis and mathematical morphology
(1982) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(82)90078-8 · Cited by 8,151
Image Analysis and Mathematical Morphology.
Diggle, P. J., & Serra, J. (1983) · Biometrics · doi:10.2307/2531038 · Cited by 3,894
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Parfitt, A. M., Mathews, C. H., Villanueva, A. R., Kleerekoper, M., Frame, B., & Rao, D. S. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111096 · Cited by 1,545
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Self-citationThe relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Self-citationOn the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationKoch, J. C. (1917) · American Journal of Anatomy · doi:10.1002/aja.1000210202 · Cited by 626
The quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579
Cited by
Bone Microdamage and Skeletal Fragility in Osteoporotic and Stress Fractures
Burr, D. B., Forwood, M. R., Fyhrie, D. P., Martin, R. B., Schaffler, M. B., & Turner, C. H. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.6 · Cited by 686
Age‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186
A Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
Zysset, P. K., Goulet, R. W., & Hollister, S. J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834756 · Cited by 105
Self-citation
Metadata
- Authors
- Goldstein, S. A., Goulet, R., & McCubbrey, D.
- Venue
- Calcified Tissue International
- Published
- 1993-02
- Volume
- 53
- Issue
- S1
- Pages
- S127-S133
- ISSN
- 0171-967X (ISSN-L)
- 1432-0827
- OpenAlex
- W2031120011
- Cited by
- 310
- References
- 33
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone. https://app.cochat.ai/papers/10.1007/bf01673421
- The paper
- Goldstein, S. A., Goulet, R., & McCubbrey, D. (1993). Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone. Calcified Tissue International. https://doi.org/10.1007/bf01673421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.