Muscular sound and force relationship during isometric contraction in man
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Motor Units: Anatomy, Physiology, and Functional Organization
Burke, R. E. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010210 · Cited by 782
Human Muscle Function and Fatigue
Edwards, R. H. T. (1981) · Novartis Foundation Symposia · doi:10.1002/9780470715420.ch1 · Cited by 626 · cited 1×
“It is known that the iEMG is influenced not only by the number of activated MUs, but also by their firing rate (Bergstrom 1959; Kuroda et al. 1970; Edwards 1981).”
BackgroundMotor unit and muscle activity in voluntary motor control.
Freund, H. J. (1983) · Physiological Reviews · doi:10.1152/physrev.1983.63.2.387 · Cited by 406 · cited 4×
“During an isometric contraction of moderate intensity the active MUs are composed essentially of type I, slow twitch (ST) fibres, (Burke 1981; Freund 1983) and the force output is controlled by varying the number of active MUs (Burke 1981; Enoka and Stuart 1985).”
BackgroundInfluentialIntramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355 · cited 1×
“A possible concurrent factor in the reduction of the SMG amplitude at 90%-100% MVC could be the increased intramuscular pressure and reduced muscle compliance (Sadamoto et al. 1983; Sejersted et al. 1984).”
BackgroundSkeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans
Sadamoto, T., Bonde-Petersen, F., & Suzuki, Y. (1983) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00429076 · Cited by 322 · cited 1×
“A possible concurrent factor in the reduction of the SMG amplitude at 90%-100% MVC could be the increased intramuscular pressure and reduced muscle compliance (Sadamoto et al. 1983; Sejersted et al. 1984).”
BackgroundMotor unit activity and surface electromyogram power spectrum during increasing force of contraction
Moritani, T., & Muro, M. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00690890 · Cited by 301 · cited 1×
“A suitable duration of contraction was chosen to avoid fatigue (Moritani and Muro 1987).”
MethodHuman muscle fatigue: physiological mechanisms.
Porter, R., & Whelan, J. (1981) · PubMed · Cited by 296
Acoustic myography: A noninvasive monitor of motor unit fatigue
Barry, D. T., Geiringer, S. R., & Ball, R. D. (1985) · Muscle & Nerve · doi:10.1002/mus.880080303 · Cited by 208
The sounds from single motor units in a contracting muscle
Gordon, G., & Holbourn, A. H. S. (1948) · The Journal of Physiology · doi:10.1113/jphysiol.1948.sp004290 · Cited by 199
Low frequency sounds from sustained contraction of human skeletal muscle
Oster, G., & Jaffe, J. S. (1980) · Biophysical Journal · doi:10.1016/s0006-3495(80)85080-6 · Cited by 180 · cited 3×
“1986), the physiological tremor (Oster and Jaffe 1980) and the actomyosin crossbridge cycling, with special reference to adenosine triphosphate turnover in fast twitch fibres (Oster 1984), have been suggested.”
BackgroundMethodInfluentialThe mechanism of low-frequency sound production in muscle
Frangioni, J. V., Kwan-Gett, T. S., Dobrunz, L. E., & McMahon, T. A. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83404-5 · Cited by 178 · cited 1×
“However, under similar experimental conditions, the sound was shown to be generated by the "lateral motion" of the muscle as a whole when activated (Barry 1987; Frangioni et al. 1987).”
BackgroundActivity of single motor units during isometric tension
Clamann, H. P. (1970) · Neurology · doi:10.1212/wnl.20.3.254 · Cited by 170 · cited 2×
“The low peak tension (Burke 1981) and the deep location of the ST fibres in the muscle body (Clamann 1970) and the consequent "damping" exerted by the surrounding tissues may explain the reduced slope of the iSMG vs MVC% relationship found in the lower range of contraction intensity.”
BackgroundAcoustic signals from frog skeletal muscle
Barry, D. T. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83403-3 · Cited by 164 · cited 1×
“However, under similar experimental conditions, the sound was shown to be generated by the "lateral motion" of the muscle as a whole when activated (Barry 1987; Frangioni et al. 1987).”
BackgroundSome features of different motor units in human biceps brachii
Gydikov, A., & Kosarov, D. (1974) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00587056 · Cited by 152 · cited 1×
“In addition to an increase in the discharge rate of the ST fibres as the force output increases, a recruitment of type II, fast twitch (FT) fibres, especially above 30% MVC, occurs (Gydikov and Kosarov 1974).”
BackgroundParasites that Change the Behavior of their Host
Moore, J. (1984) · Scientific American · doi:10.1038/scientificamerican0584-108 · Cited by 107
Electrical and metabolic activities and fatigue in human isometric contraction.
Kuroda, E., Klissouras, V., & Milsum, J. H. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.3.358 · Cited by 84 · cited 1×
“It is known that the iEMG is influenced not only by the number of activated MUs, but also by their firing rate (Bergstrom 1959; Kuroda et al. 1970; Edwards 1981).”
BackgroundInvestigation of Sounds Produced by Healthy and Diseased Human Muscular Contraction
Rhatigan, B. A., Mylrea, K. C., Lonsdale, E. M., & Stern, L. Z. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325668 · Cited by 69 · cited 1×
“As additional sources, the oscillations caused by the elastic connective tissue at every individual contraction (Rhatigan et al. 1986), the physiological tremor (Oster and Jaffe 1980) and the actomyosin crossbridge cycling, with special reference to adenosine triphosphate turnover in fast twitch fibres (Oster 1984), h…”
BackgroundThe contribution of neuroscience to exercise studies.
Enoka, R. M., & Stuart, D. G. (1985) · PubMed · Cited by 50
Muscle contraction generates discrete sound bursts
Brozovich, F. V., & Pollack, G. H. (1983) · Biophysical Journal · doi:10.1016/s0006-3495(83)84403-8 · Cited by 45 · cited 2×
“The variations of the transverse diameter of the muscle fibre have been indicated as one of the basic events in the generation of the SMG (Gordon and Holbourn 1948; Brozovich and Pollack 1983).”
BackgroundOster, G. D. (1984) · Scientific American · doi:10.1038/scientificamerican0384-108 · Cited by 31
Cited by
Orizio, C., Gobbo, M., Diemont, B., Esposito, F., & Veicsteinas, A. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0924-1 · Cited by 260
Self-citationBeck, T. W., Housh, T. J., Cramer, J. T., Weir, J. P., Johnson, G. O., Coburn, J. W., Malek, M. H., & Mielke, M. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-67 · Cited by 192
“In addition, several investigations [8,27,66,109] have suggested that during isometric muscle actions at high torque levels, muscle stiffness may restrict the lateral oscillations of the active muscle fibers, thereby decreasing MMG amplitude.”
InfluentialMadeleine, P., Bajaj, P., Søgaard, K., & Arendt-Nielsen, L. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00044-4 · Cited by 186
1998 ISEK Congress Keynote Lecture
Moritani, T., & Yoshitake, Y. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00018-2 · Cited by 50
Metadata
- Authors
- Orizio, C., Perini, R., & Veicsteinas, A.
- Venue
- European Journal of Applied Physiology and Occupational Physiology
- Published
- 1989-03
- Volume
- 58
- Issue
- 5
- Pages
- 528-533
- ISSN
- 0020-9376 (ISSN-L)
- 0301-5548
- 1439-6327
- OpenAlex
- W1964552084
- Cited by
- 197
- References
- 20
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.