The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review
Open accessAbstract
The purpose of this review is to examine the literature that has investigated mechanomyographic (MMG) amplitude and frequency responses during dynamic muscle actions. To date, the majority of MMG research has focused on isometric muscle actions. Recent studies, however, have examined the MMG time and/or frequency domain responses during various types of dynamic activities, including dynamic constant external resistance (DCER) and isokinetic muscle actions, as well as cycle ergometry. Despite the potential influences of factors such as changes in muscle length and the thickness of the tissue between the muscle and the MMG sensor, there is convincing evidence that during dynamic muscle actions, the MMG signal provides valid information regarding muscle function. This argument is supported by consistencies in the MMG literature, such as the close relationship between MMG amplitude and power output and a linear increase in MMG amplitude with concentric torque production. There are still many issues, however, that have yet to be resolved, and the literature base for MMG during both dynamic and isometric muscle actions is far from complete. Thus, it is important to investigate the unique applications of MMG amplitude and frequency responses with different experimental designs/methodologies to continually reassess the uses/limitations of MMG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Kraemer, W. J., Patton, J. F., Gordon, S. E., Harman, E. A., Deschenes, M. R., Reynolds, K., Newton, R. U., Triplett, N. T., & Dziados, J. E. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.78.3.976 · Cited by 782 · cited 1×
“Resistance training results in increases in muscle fiber size (hypertrophy) [98,99] and muscle stiffness [100], and it has been suggested [94,95] that both of these factors may influence the amplitude and/or frequency contents of the MMG signal.”
Acoustic myography: A noninvasive monitor of motor unit fatigue
Barry, D. T., Geiringer, S. R., & Ball, R. D. (1985) · Muscle & Nerve · doi:10.1002/mus.880080303 · Cited by 208
Cited by
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Xie, H.-B., Zheng, Y.-P., & Guo, J.-Y. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/5/002 · Cited by 118
Hand-motion patterns recognition based on mechanomyographic signal analysis
Zeng, Y., Yang, Z., Cao, W., & Xia, C. (2009) · 2009 International Conference on Future BioMedical Information Engineering (FBIE) · doi:10.1109/fbie.2009.5405882 · Cited by 24
Cochrane-Snyman, K. C., Housh, T. J., Smith, C. M., Hill, E. C., Jenkins, N. D. M., Schmidt, R. J., & Johnson, G. O. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3394-y · Cited by 20
Self-citation
Metadata
- Authors
- Beck, T. W., Housh, T. J., Cramer, J. T., Weir, J. P., Johnson, G. O., Coburn, J. W., Malek, M. H., & Mielke, M.
- Venue
- BioMedical Engineering OnLine
- Published
- 2005-12
- Volume
- 4
- Issue
- 1
- Pages
- 67-67
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W1512847092
- Cited by
- 192
- References
- 3
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review. https://app.cochat.ai/papers/10.1186/1475-925x-4-67
- The paper
- Beck, T. W., Housh, T. J., Cramer, J. T., Weir, J. P., Johnson, G. O., Coburn, J. W., Malek, M. H., & Mielke, M. (2005). Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-4-67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.