Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.
Abstract
Development of a non-invasive method for measuring the blood glucose level is an urgent necessity, and putting such a method into practical use will enable some of the physical and mental stress that patients with diabetes have to endure to be removed. To realise a non-invasive blood glucose monitor, the gingival crevicular fluid (GCF) was measured. A GCF-collecting device was developed that was designed to be disposable, biocompatible and small enough to be inserted in the gingival crevice for collection of a sub-microlitre sample of GCF. Also, a high-sensitivity glucose testing tape incorporated in the device was developed. Red laser light in a portable optical device measured the colour density of the testing tape. Standard glucose solutions were used to investigate the measurement accuracy of the GCF glucose monitor and showed a correlation coefficient of R = 0.99 (n = 20) between the optical density and the glucose levels. The GCF glucose monitor was evaluated on healthy Swedish and Japanese adults (n = 10) and both GCF glucose levels (GCFLs) and blood glucose levels (BGLs) were measured in conjunction with meal loads. The GCFLs were about 1/10-1/560 lower than the BGLs. No difference in the range of GCFLs between the Swedish and the Japanese subjects was observed. Therefore it was concluded that physique, body mass index and life-style, such as dietary habit, did not significantly influence the GCFLs. Further, the correlation coefficients of all the subjects were 0.70 and 0.88 with each group. It was suggested that GCF could be used as a method of non-invasive blood glucose measurement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nevertheless, glucose is available in gingival crevicular fluid,28”
From The dental plaque biofilm matrix (2021) · cites this paper as [28]
Citations
Cites
Transdermal monitoring of glucose and other analytes using ultrasound
Kost, J., Mitragotri, S., Gabbay, R. A., Pishko, M., & Langer, R. (2000) · Nature Medicine · doi:10.1038/73213 · Cited by 253
Noninvasive Blood Glucose Monitoring
Klonoff, D. C. (1997) · Diabetes Care · doi:10.2337/diacare.20.3.433 · Cited by 208
The Passage of Tissue Fluid into the Clinically Healthy Gingival Pocket
Brill, N., & Krasse, B. O. (1958) · Acta Odontologica Scandinavica · doi:10.3109/00016355809064110 · Cited by 198
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
Tamada, J. A., Bohannon, N. J. V., & Potts, R. O. (1995) · Nature Medicine · doi:10.1038/nm1195-1198 · Cited by 182
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129 · cited 1×
“On the other hand, measurements of glucose concentrations in naturally secreted fluids such as saliva (YAMAGUCHI et al., 1998; 2000) and in body fluid extracted by reverse-iontophoresis (TAMADA e t al.”
BackgroundSelf-citationCsoeregi, E., Schmidtke, D. W., & Heller, A. (1995) · Analytical Chemistry · doi:10.1021/ac00103a015 · Cited by 129
Reverse Iontophoresis: Development of a Noninvasive Approach for Glucose Monitoring
Rao, G., Glikfeld, P., & Guy, R. H. (1993) · Pharmaceutical Research · doi:10.1023/a:1018926215306 · Cited by 126
Phantom Glucose Calibration Models from Simulated Noninvasive Human Near-Infrared Spectra
Arnold, M. A., Burmeister, J. J., & Small, G. W. (1998) · Analytical Chemistry · doi:10.1021/ac9710801 · Cited by 117
A comparison of the glucose and protein content of gingival fluid from diabetics and nondiabetics
Ficara, A. J., Levin, M. P., Grower, M., & Kramer, G. D. (1975) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1975.tb00022.x · Cited by 105
An Overview of Minimally Invasive Technologies
Ginsberg, B. H. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1596 · Cited by 71
Research works printed but not linked: 4
- Yamaguchi, M., Satou, D., andTakai, N. (2000): ‘Trial manufacture of a noninvasive blood glucose meter using saliva’,16th Int. Conf. on Oral Biology,34, p. 32
- Yamaguchi, M., Fukushi, Y., Yamazaki, K., andKobayashi, M. (2001): ‘Gingival crevicular fluid collecting device used for analyzing microvolume sample solutions’,Sensors Mater.,13, pp. 155–167
- Yamaguchi, M., Kambe, S., Naitoh, K., Kamei, T., andYoshida, H. (2002): ‘Gingival crevcular fluid-collecting device for noninvasive blood glucose monitoring’.2nd Joint EMBS-BMES Conf., pp. 1809–1810
- Yoshida, Y. (2000): ‘Possible use of oral fluids for screening human systemic diseases (in Japanese)’,Shika Igaku (J. Osaka Odontol Soc.),63, pp. 64–71
Cited by
The dental plaque biofilm matrix
Jakubovics, N. S., Goodman, S. D., Mashburn‐Warren, L., Stafford, G. P., & Cieplik, F. (2021) · Periodontology 2000 · doi:10.1111/prd.12361 · Cited by 488
Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics
Malon, R. S. P., Sadir, S., Balakrishnan, M., & Córcoles, E. P. (2014) · BioMed Research International · doi:10.1155/2014/962903 · Cited by 260
“Finally, the result is processed using associated electronics and embedded software systems, which provide simple digital feedback displayed using a reader device in a user-friendly manner for interpretation by nonexperts [5].”
MethodMetabolite Cross-Feeding Enhances Virulence in a Model Polymicrobial Infection
Ramsey, M. M., Rumbaugh, K. P., & Whiteley, M. (2011) · PLoS Pathogens · doi:10.1371/journal.ppat.1002012 · Cited by 238
Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 207
Ramsey, M. M., & Whiteley, M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809533106 · Cited by 168
Brown, S. A., & Whiteley, M. (2007) · Journal of Bacteriology · doi:10.1128/jb.00554-07 · Cited by 115
Control oriented model of insulin and glucose dynamics in type 1 diabetics
Fabietti, P. G., Canonico, V., Federici, M. O., Benedetti, M. M., & Sarti, E. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-005-0012-2 · Cited by 102
Glucose Concentration Measurement in Human Blood Plasma Solutions with Microwave Sensors
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., & Sabater-Navarro, J. M. (2019) · Sensors · doi:10.3390/s19173779 · Cited by 65
Hanes, P. J., & Krishna, R. (2010) · The EPMA Journal · doi:10.1007/s13167-010-0016-3 · Cited by 59
Strauss, S. M., Wheeler, A. J., Russell, S. L., Brodsky, A., Davidson, R. M., Gluzman, R., Lin, L., Malo, R. G., Salis, B., Schoor, R., et al. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080542 · Cited by 53
Detection of saliva-range glucose concentrations using organic thin-film transistors
Elkington, D. C., Belcher, W. J., Dastoor, P. C., & Zhou, X. (2014) · Applied Physics Letters · doi:10.1063/1.4892012 · Cited by 48
Elkington, D. C., Wasson, M., Belcher, W. J., Dastoor, P. C., & Zhou, X. (2015) · Applied Physics Letters · doi:10.1063/1.4923397 · Cited by 43
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36
Gingival Crevicular Blood as a Potential Screening Tool: A Cross Sectional Comparative Study
Rapone, B., Ferrara, E., Santacroce, L., Topi, S., Converti, I., Gnoni, A., Scarano, A., & Scacco, S. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17207356 · Cited by 36
Point of care testing system via enzymatic method for the rapid, efficient assay of glycated albumin
Yamaguchi, M., Kambe, S., Eto, T., Yamakoshi, M., Kouzuma, T., & Suzuki, N. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.002 · Cited by 35
Self-citationOral fluid-based biosensors: A novel method for rapid and noninvasive diagnosis
Lakshmi, K., Nelakurthi, H., Kumar, A., & Amrutha, R. (2017) · Indian Journal of Dental Sciences · doi:10.4103/ijds.ijds_6_17 · Cited by 32
Evaluation of Time-Course Changes of Gingival Crevicular Fluid Glucose Levels in Diabetics
Yamaguchi, M., Takada, R., Kambe, S., Hatakeyama, T., Naitoh, K., Yamazaki, K., & Kobayashi, M. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6172-x · Cited by 27
Self-citationGingival Crevicular Blood for Assessment of Blood Glucose Levels
Sarlati, F., Pakmehr, E., Khoshru, K., & Akhondi, N. (2010) · Tabriz University of Medical Sciences · doi:10.5681/jpid.2010.003 · Cited by 16
Error Grid Analysis of Noninvasive Glucose Monitoring Via Gingival Crevicular Fluid
Yamaguchi, M., Kambe, S., Yamazaki, K., & Kobayashi, M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847555 · Cited by 13
Self-citationNon-invasive glucose measuring apparatus based on conservation of energy method
Chen, Z., Jin, X.-L., Zhu, J., Wang, D., & Zhang, T. (2009) · Journal of Central South University of Technology · doi:10.1007/s11771-009-0163-7 · Cited by 9
Patil, D. J. (2014) · Journal of Oral Hygiene & Health · doi:10.4172/2332-0702.1000166 · Cited by 7
Bhardwaj, A., Singh, S., Chopra, P., & Masamatti, S. S. (2019) · Indian Journal of Dental Sciences · doi:10.4103/ijds.ijds_100_18 · Cited by 6
Dental plaque biofilm-targeting composite nanomaterials: advances and outlook
Zhao, J., Huang, S., Yang, Y., Wang, J., Guo, Q., Xu, Y., Jiang, B., & Lin, J. (2026) · Biomaterials Science · doi:10.1039/d5bm01747e · Cited by 5
The Need to Pair Molecular Monitoring Devices with Molecular Imaging to Personalize Health
Comeau, Z. J., Lessard, B. H., & Shuhendler, A. J. (2022) · Molecular Imaging and Biology · doi:10.1007/s11307-022-01714-4 · Cited by 4
Understanding Inflammation: The Key to Targeted Preventive Measures for Diabetes and Periodontitis
Krishna, R., Hanes, P. J., & Cutler, C. W. (2013) · Advances in predictive, preventive and personalised medicine · doi:10.1007/978-94-007-5971-8_12 · Cited by 2
Ramsey, M. M. (2011) · Texas ScholarWorks (Texas Digital Library) · Cited by 1
Non‐invasive Glucose Biosensors Based on Nanomaterials
Faridbod, F., Ganjali, M. R., Larijani, B. A., & Norouzil, P. (2015) · Wiley eBooks · doi:10.1002/9781118998922.ch10 · Cited by 1
Mârțu, M.-A., STEFANACHE, T., Păsărin, L., Liliana, F. O. I. A., & Mârţu, S. (2013) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 1
Diş Eti Oluğu Kanı ve Tıbbi Diagnostik Değeri
Hatipoğlu, H. (2022) · European Journal of Research in Dentistry · doi:10.29228/erd.25
Juan, C. G. (2021) · Springer theses · doi:10.1007/978-3-030-76179-0_2
Dental, S., Awad, M. A., & Arabia, S. (2014)
Martinovic, L., Šantić, R., Kuliš, E., Martinović, D., Kumrić, L. J., Kumrić, M., & Božić, J. (2026) · Gels · doi:10.3390/gels12100897
Hirose, Y., Bando, A., Sugiyama, M., Tabata, A., Morikita, K., Tabuchi, T., Nishimura, Y., Tamura, R., Mori, A., Ono, M., et al. (2026) · Microbial Pathogenesis · doi:10.1016/j.micpath.2026.108794
Dubey, A., Dwivedi, I. K., & Tripathi, S. (2026) · IEEE Sensors Letters · doi:10.1109/lsens.2026.3705902
Gingival Crevicular Blood- A Reliable Tool for Assessment of Blood Glucose Levels in Dental Office
Patil, D. J., & Kamalakannan, D. (2021) · Book Publisher International (a part of SCIENCEDOMAIN International) · doi:10.9734/bpi/hmmr/v6/1890f
富山大学工学部 (2006) · Institutional Repositories DataBase (IRDB)
富山大学工学部 (2005) · Institutional Repositories DataBase (IRDB)
Yan, Y., Veronica, A., Wang, C., Guo, Y., He, A., Gu, M., Zhang, L. F., Han, G., Cui, J. Q., Chandwaney, S. V., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg8698
Sehar, K., Singh, J., Garg, S., Goel, V., & Gill, S. (2026) · IOSR Journal of Dental and Medical Sciences · doi:10.9790/0853-2506015664
富山大学工学部 (2005) · Institutional Repositories DataBase (IRDB)
Metadata
- Authors
- Yamaguchi, M., Kawabata, Y., Kambe, S., W⇘rdell, K., Nystrom, F. H., Naitoh, K., & Yoshida, H.
- Affiliations
- University of Toyama (JP)
- Suzuken (Japan) (JP)
- Nipro (Japan) (JP)
- Corresponding author
- Yamaguchi, M.
- ORCID
- Yamaguchi, M.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2004-05
- Volume
- 42
- Issue
- 3
- Pages
- 322-327
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2092541408
- Semantic Scholar
- ebc9b2a164fe22138b15411d21204f2faef0883f
- Cited by
- 36
- References
- 15
- Citations by year
- 2026: 3 · 2025: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 3 · 2017: 1 · 2015: 2 · 2014: 4 · 2013: 2
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Dentistry › Periodontics › Oral microbiology and periodontitis research
- Keywords
- gingival crevicular fluid, non-invasive glucose monitoring, diabetes mellitus, body mass index, cross-cultural comparison
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Female, Gingival Crevicular Fluid, Glucose, Humans, Male, Blood Glucose Self-Monitoring, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.