Tuned vibration absorber for suppression of rest tremor in Parkinson’s disease
Abstract
A simple approach for the suppression of the tremor associated with Parkinson's disease is presented. The proposed system is a tuned vibration absorber (TVA), which has been very effective in the suppression of vibrations in an experimental model of the human arm with two degrees of freedom. Theoretical and numerical methods were used to study the behaviour of the arm model and to develop an effective tremor reduction approach. Based on these studies, a vibration absorber was designed, tested numerically and fabricated for experimental testing. Experimental investigations indicated that optimum control performance was related to the position of the controller and the excitation frequency. With a distance of 160 mm from the end of forearm, the TVA was found to have the best performance, and, for different tremor frequencies, the vibration of the experimental model was reduced by more than 80%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The impedance controller can modify the biomechanical characteristics of the system (robot and limb) to achieve attenuation at the tremor frequency.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Hashemi et al., 2004
Citations
Cites
Parkinson, J. (2002) · Journal of Neuropsychiatry · doi:10.1176/jnp.14.2.223 · Cited by 2,864
Theoretical and Experimental Modal Analysis
Maia, N., & Silva, J. M. M. E. (1997) · Cited by 1,291
Passive, Adaptive and Active Tuned Vibration Absorbers—A Survey
Sun, J., Jolly, M. R., & Norris, M. A. (1995) · Journal of Mechanical Design · doi:10.1115/1.2836462 · Cited by 326
Active and Semi-Active Vibration Isolation
KARNOPP, D. C. (1995) · Journal of vibration and acoustics · doi:10.1115/1.2838660 · Cited by 274
A dynamic model for simulating movements of the elbow, forearm, and wrist
Lemay, M. A., & Crago, P. E. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00026-7 · Cited by 228
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150
The mechanical behavior of active human skeletal muscle in small oscillations
Cannon, S. C., & Zahalak, G. I. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90043-4 · Cited by 133
Fundamentals of applied dynamics
(2004) · Choice Reviews Online · doi:10.5860/choice.41-6560 · Cited by 132
NAGAYA, K., KURUSU, A., Shigeo, I. K. A. I., & SHITANI, Y. (1999) · Journal of Sound and Vibration · doi:10.1006/jsvi.1999.2443 · Cited by 104
A general approach for modelling and mathematical investigation of the human upper limb
Raikova, R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90226-q · Cited by 84
Research works printed but not linked: 6
- Flanagan, J. R., Feldman, A. G. andOstry, D. J. (1992): ‘Equilibrium trajectories underlying rapid target-directed arm movements’,Tutor. Motor Behav., pp. 661–675
- Griffin, G. J. (1990): ‘Handbook of human vibration’ (Academic Press, 1990), p. 182
- Inman, D.J. (1996): ‘Engineering vibration’ (Prentice Hall, 1996)
- Li, L. (2000): ‘Modelling and tremor suppression of human arm with Parkinson's disease’, MSc thesis, (Department of Mechancial Engineering, University of Waterloo, Ontario, Canada
- Seto, K., andTakita, Y. (1984): ‘Vibration control in multi-degree-freedom systems, Report 1: On the design of dynamic absorbers’,Trans. Jpn Soc. Mech. Eng.,50, p. 458
- Yang, Y., Yahia, L., andFeldman, A. G. (1993): ‘A versatile dynamic model of human arm’,Adv. Bioeng. ASME,26, pp. 36–47
Cited by
Sorted by citations
Robust Controller for Tremor Suppression at Musculoskeletal Level in Human Wrist
Taheri, B., Case, D., & Richer, E. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2295034 · Cited by 63
A Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
“It is not uncommon to assess tremor suppression methods by performing simulations, either numerically or experimentally (Hashemi et al., 2004; Popović et al., 2010; Veluvolu and Ang, 2011; Zhang et al., 2011; Taheri et al., 2012, 2015; Chuanasa and Songschon, 2014; Wang et al., 2014) and…”
MethodBarroso, M. C., Esteves, G., Nunes, T. P., Silva, L. M., Faria, Á. C. D., & de Melo, P. L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-14 · Cited by 43
A wearable elbow exoskeleton for tremor suppression equipped with rotational semi-active actuator
Zahedi, A., Wang, Y., Martínez-Hernández, U., & Zhang, D. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107674 · Cited by 38
4D printing of soft orthoses for tremor suppression
Mohammadi, M., Zolfagharian, A., Bodaghi, M., Xiang, Y., & Kouzani, A. Z. (2022) · Bio-Design and Manufacturing · doi:10.1007/s42242-022-00199-y · Cited by 37
Herrnstadt, G., McKeown, M. J., & Menon, C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0484-1 · Cited by 30
Admittance-Based Voluntary-Driven Motion With Speed-Controlled Tremor Rejection
Herrnstadt, G., & Menon, C. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2555811 · Cited by 28
Hand tremor suppression device for patients suffering from Parkinson’s disease
Faizan, M. S., & Muzammil, M. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1759708 · Cited by 24
Tremor Reduction at the Palm of a Parkinson’s Patient Using Dynamic Vibration Absorber
Gebai, S., Hammoud, M., Hallal, A., & Khachfe, H. M. (2016) · Bioengineering · doi:10.3390/bioengineering3030018 · Cited by 23
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
Zamanian, A. H., & Richer, E. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102273 · Cited by 22
Abbasi, M., Afsharfard, A., Arasteh, R., & Safaie, J. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1769-9 · Cited by 22
Marchis, C. D., Schmid, M., & Conforto, S. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.12.017 · Cited by 21
Pigg, A. C., Thompson‐Westra, J., Mente, K., Maurer, C. W., Haubenberger, D., Hallett, M., & Charles, S. K. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.08.010 · Cited by 20
Active tremor estimation and suppression in human elbow joint
Taheri, B., Case, D., & Richer, E. (2011) · ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 · doi:10.1115/dscc2011-6185 · Cited by 18
Designing a hand rest tremor dynamic vibration absorber using H 2 optimization method
Rahnavard, M., Hashemi, M., Farahmand, F., & Dizaji, A. F. (2014) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-014-0104-8 · Cited by 19
An adaptive pendulum for evolving structures
Mekki, O. B., Bourquin, F., Maceri, F., & Phu, C. N. V. (2011) · Structural Control and Health Monitoring · doi:10.1002/stc.422 · Cited by 18
Modeling and experimental study of a hand tremor suppression system
Abbasi, M., & Afsharfard, A. (2018) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2018.04.009 · Cited by 18
Hybrid learning control for improving suppression of hand tremor
As’arry, A., Zain, M. Z. M., Mailah, M., & Hussein, M. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913494325 · Cited by 17
Standring, D. J., Pigg, A. C., Thompson‐Westra, J., Mente, K., Maurer, C. W., Haubenberger, D., Hallett, M., & Charles, S. K. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.07.001 · Cited by 14
Assistive Methodologies for Parkinson's Disease Tremor Management—A Health Opinion
Dineshkumar, V., Dolly, D. R. J., Jagannath, D. J., & Peter, J. D. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.850805 · Cited by 12
Nonlinear Vibration of a Sliding-Mode-Controlled Structure: Simulation and Experiment
Mesny, L., Baguet, S., & Chesné, S. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111209 · Cited by 11
Parkinson’s Disease Treatment as Seen from a Mechanical Point of View
Gebai, S., & Hammoud, M. (2016) · Advances in Parkinson s Disease · doi:10.4236/apd.2016.54012 · Cited by 10
Gebai, S., Hammoud, M., Hallal, A., Shaer, A. A., & Khachfe, H. M. (2016) · International Conference on Advances in Computational Tools for Engineering Applications · doi:10.1109/actea.2016.7560132 · Cited by 10
Parametric study of an enhanced passive absorber used for tremor suppression
Gebai, S., Hammoud, M., & Khachfe, H. M. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2177 · Cited by 10
A self-tunable dynamic vibration absorber: Parkinson's Disease's tremor suppression
Teixeira, C., Bicho, E. G., Rocha, L. A., & Gago, M. F. (2013) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2013.6518440 · Cited by 10
Essential tremor suppression by a novel self-balancing device
Chuanasa, J., & Songschon, S. (2014) · Prosthetics and Orthotics International · doi:10.1177/0309364614525185 · Cited by 9
Nonlinear passive tremor control of human arm
Savadkoohi, A. T., Lamarque, C., & Goossaert, C. (2021) · Mechanical systems and signal processing · doi:10.1016/j.ymssp.2020.107041 · Cited by 8
EFFECT OF GYROSCOPE PARAMETERS ON GYROSCOPIC TREMOR SUPPRESSION IN A SINGLE DEGREE OF FREEDOM
Allen, B. C., & Charles, S. K. (2019) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519419500246 · Cited by 7
Elbow Orthosis for Tremor Suppression – A Torque Based Input Case
Herrnstadt, G., & Menon, C. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-56148-6_25 · Cited by 7
Wang, S., Gao, Y., Zhu, Y., & Zhao, J. (2016) · Advances in Mechanical Engineering · doi:10.1177/1687814016654872 · Cited by 6
Biomechanical treatment for rest tremor of Parkinson's patient
Gebai, S., Hammoud, M., Hallal, A., Shaer, A. A., & Khachfe, H. M. (2016) · IEEE International Multidisciplinary Conference on Engineering Technology (IMCET) · doi:10.1109/imcet.2016.7777422 · Cited by 6
Optimal design of a vibration absorber for tremor control of arm in Parkinson's disease
Hosseini, R., Firoozbakhsh, K. K., & Naseri, H. (2014) · Journal of Computational & Applied Research in Mechanical Engineering (JCARME) · doi:10.22061/jcarme.2014.62 · Cited by 5
Robust Tremor Attenuation for Single DOF Model of Human Elbow Joint With Parametric Uncertainties
Taheri, B., Case, D., & Richer, E. (2011) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2011-64443 · Cited by 5
Upper limb involuntary tremor reduction using cantilever beam TMDs
Gebai, S., Cumunel, G., Hammoud, M., Foret, G., Roze, E. F., & Hainque, É. (2022) · Journal of Vibration and Control · doi:10.1177/10775463211051869 · Cited by 5
Toward quantitative characterization of essential tremor for future tremor suppression
Charles, S. K., Geiger, D. W., Davidson, A. D., Pigg, A. C., Curtis, C. P., & Allen, B. C. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009242 · Cited by 4
Development of a Textile Integrated, Two-State Controlled Tremor Suppression Orthosis for the Wrist
Fromme, N. P., Esser, A., Camenzind, M., Mylius, V., Baumann, C. R., Büchele, F., Riener, R., Wolf, P., & Rossi, R. M. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3293192 · Cited by 3
Dynamics and vibration suppression of resting tremor based on inertial nonlinear energy sink
Qi, X.-K., Zhang, J., & Wang, J. (2025) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2025.117732 · Cited by 3
Wearable Metamaterials with Embodied Intelligence for Programmable Control of Human Limbs Tremor
de Moura, B. B., Machado, M., & Mukhopadhyay, T. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500307 · Cited by 3
Biomechanical Upper Limb Model for Postural Tremor Absorber Design
Gebai, S., Cumunel, G., Hammoud, M., Foret, G., Roze, E. F., & Hainque, É. (2022) · Dynamics · doi:10.3390/dynamics2030012 · Cited by 3
Computational study and validation of a novel passive hand tremor attenuator
Shah, M. R., Goode, D., & Mohammadi, H. (2022) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2022.2134482 · Cited by 3
Development of an Active Dynamic Vibration Absorber for Palm Tremors in Parkinson's Disease Patients
Tran, T. M., & Nguyen, S. H. (2024) · International Journal of Mathematical Engineering and Management Sciences · doi:10.33889/ijmems.2024.9.6.068 · Cited by 3
Designs of Upper Limb Tremor Suppression Orthoses: Efficacy and Wearer's Comfort
ChiGan, M., Chen, M., & Jing, M. (2024) · Journal of Medical Devices · doi:10.1115/1.4066968 · Cited by 2
Baker, S. A., Beutler, L. J., Free, D. B., Farina, D., & Charles, S. K. (2025) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.949 · Cited by 2
Mohanty, S., & Dwivedy, S. K. (2022) · Lecture notes in mechanical engineering · doi:10.1007/978-981-16-6738-1_53 · Cited by 2
Teixeira, C., Bicho, E. G., Rocha, L. A., & Gago, M. F. (2013) · UKSim International Conference on Computer Modelling and Simulation (UKSim) · doi:10.1109/uksim.2013.15 · Cited by 2
The Design and Implementation of a Low-Cost Demo Tool to Teach Dynamics in the IOT Era
Yuen, T., Balan, L., & Mehrtash, M. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-11434-3_26 · Cited by 2
Zhao, G., Wang, Z., Zhao, H., & Yang, J. (2018) · Materials Research Express · doi:10.1088/2053-1591/aadc54 · Cited by 2
Self-Powered Medical Devices for Vibration Suppression
Swallow, L. M., Siores, E., Dodds, D., & Luo, J. K. (2010) · Elsevier eBooks · doi:10.1533/9780857090348.415 · Cited by 2
A Self-Tunable Dynamic Vibration Absorber for Tremor Suppression
Teixeira, C. J., Bicho, E. G., Gago, M. F., & Rocha, L. A. (2013) · Biomedical Engineering · doi:10.2316/p.2013.791-039 · Cited by 1
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Involuntary tremor controlled using mechanical means: Involunatry hand tremor
Gebai, S., Hammoud, M., Hallal, A., & Shaer, A. A. (2017) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme.2017.8167537 · Cited by 1
Zhao, G., Yang, J., Wu, Y., Zhao, H., & Wang, Z. (2018) · Materials Research Express · doi:10.1088/2053-1591/aadddf · Cited by 1
Postural Tremor Reduction System Design for Parkinson’s Disease Patients
Lopez, M. J. E., & Rodríguez-Morales, Á. L. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-30648-9_155 · Cited by 1
Non-invasive Device to Lessen Tremors in the Hands due to Parkinson’s Disease
Hinostroza-Quinones, J., & Vasquez-Cunia, M. (2020) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2020.0110889 · Cited by 1
Suppression of Tremors in Parkinson’s Patients Using a Dynamic Vibration Absorber
Rihan, N., Muthalif, A. G. A., Syam, T., & Nordin, N. H. D. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-33-4597-3_46 · Cited by 1
Optimization of passive cantilever-type tuned mass damper to reduce the hand postural tremor
Gebai, S. (2020) · theses.fr (ABES) · doi:10.70675/994e0848ze136z4e48z8db8z9981215dcb5b · Cited by 1
Voluntary Driven, Velocity Controlled Tremor Suppression
Herrnstadt, G. (2017) · Summit (Simon Fraser University)
Widjaja, F. (2011) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/42882
Mohanty, S., & Dwivedy, S. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-4056-1_25
Premchand, V. P., Balaram, B., Mani, A. K., Sajith, A. S., & Narayanan, M. D. (2024) · Springer proceedings in mathematics & statistics · doi:10.1007/978-3-031-56492-5_30
Spoon4PD: a smart tool 3D printed for Parkinson’s disease
Zain, M. Z. M., Wahid, M. A., Bodaghi, M., & Zolfagharian, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13673-3.00009-2
Design of Passive Dynamic Absorbers to Attenuate Pathological Tremor of Human Upper Limb
de Albuquerque, G. G. D. S. B., & Machado, M. (2025) · Lecture notes in mechanical engineering · doi:10.1007/978-3-031-71540-2_20
Experimental and computational analysis and testing of wearable hand tremor control orthoses
Shah, M. R., Goode, D., & Mohammadi, H. (2025) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2025.2593410
امتمحمدی, م., نورانی, س. م. ر. س., & صادقی, س. (2025) · Muhandisī-i mikānīk-i Sharīf/Muhandisī-i mikānīk-i Sharīf · doi:10.24200/j40.2025.65739.1727
Simulated effects of the peripheral musculoskeletal system on hand tremor
Beutler, L. J., Baker, S. A., Syndergaard, I., Farina, D., & Charles, S. K. (2026) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2026.111670
Liu, Q., Liu, H., Jiang, Y., Wang, Z., He, J., Liu, X., & Zou, R. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-7322-6_3
Koubbi, A., Boughrara, B., Sebbar, S., & Salih-Alj, Y. (2026) · International Conference on Mechatronics and Robotics Engineering (ICMRE) · doi:10.1109/icmre69538.2026.11533988
Nonlinear absorber device to treat essential tremor: The TREM-AB open-label pilot study
Laurencin, C., Millot-Troesch, M., Blanc-Gonnet, J., Lamarque, C. H., Thobois, S., & Savadkoohi, A. T. (2026) · Revue Neurologique · doi:10.1016/j.neurol.2026.09.010
Metadata
- Authors
- Hashemi, S. M., Golnaraghi, M. F., & Patla, A. E.
- Affiliations
- Toronto Metropolitan University (CA)
- University of Waterloo (CA)
- Corresponding author
- Hashemi, S. M.
- ORCID
- Hashemi, S. M.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2004-01
- Volume
- 42
- Issue
- 1
- Pages
- 61-70
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2016034137
- Cited by
- 68
- References
- 19
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 4 · 2023: 4 · 2022: 7 · 2021: 2 · 2020: 6 · 2019: 5 · 2018: 5 · 2017: 4 · 2016: 7 · 2014: 4 · 2013: 4 · 2012: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- tuned vibration absorber, resting tremor, Parkinson's disease, tremor suppression, passive vibration control, controller placement, excitation frequency
- MeSH terms
- Arm, Biomechanical Phenomena, Equipment Design, Humans, Models, Biological, Parkinson Disease, Tremor, Vibration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review