CoChat

Detection of fast neuronal signals in the motor cortex from functional near infrared spectroscopy measurements using independent component analysis

Open access
Morren, G., Wolf, M., Lemmerling, P., Wolf, U., Choi, J. H., Gratton, E., De Lathauwer, L., Van Huffel, S. · 2004 · Medical and Biological Engineering and Computing
Cited by 122

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Fast changes, in the range of milliseconds, in the optical properties of cerebral tissue are associated with brain activity and can be detected using noninvasive near-infrared spectroscopy (NIRS). These changes are assumed to be caused by changes in the light scattering properties of the neuronal tissue. The aim of this study was to develop highly sensitive data analysi algorithms to detect this fast signal, which is small compared with other physiological signals. A frequency-domain tissue oximeter, whose laser diodes were intensity modulated at 110 MHz, was used. The amplitude, mean intensity and phase of the modulated optical signal were measured at a sample rate of 96 Hz. The probe, consisting of four crossed source detector pairs was placed above the motor cortex, contralateral to the hand performing a tapping exercise consisting of alternating rest and tapping periods of 20 s each. An adaptive filter was used to remove the arterial pulsatility from the optical signals. Independent component analysis allowed further separation of a signal component containing the fast signal. In nine out of 14 subjects, a significant fast neuronal signal related to the finger tapping was found in the intensity signals. In the phase signals, indications of the fast signal were found in only two subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/bf02351016

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 122

Metadata

Authors
Morren, G., Wolf, M., Lemmerling, P., Wolf, U., Choi, J. H., Gratton, E., De Lathauwer, L., & Van Huffel, S.
Venue
Medical and Biological Engineering and Computing
Published
2004-01
Volume
42
Issue
1
Pages
92-99
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W1989784044
Cited by
122
References
3
FWCI
2.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of fast neuronal signals in the motor cortex from functional near infrared spectroscopy measurements using independent component analysis. https://app.cochat.ai/papers/10.1007/bf02351016
The paper
Morren, G., Wolf, M., Lemmerling, P., Wolf, U., Choi, J. H., Gratton, E., De Lathauwer, L., & Van Huffel, S. (2004). Detection of fast neuronal signals in the motor cortex from functional near infrared spectroscopy measurements using independent component analysis. Medical and Biological Engineering and Computing. https://doi.org/10.1007/bf02351016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.