CoChat

Image quality and radiation levels in videofluoroscopy for swallowing studies: A review

Beck, T. J., Gayler, B. W. · 1990 · Dysphagia

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Inexpensive video recording equipment coupled to conventional x-ray fluoroscopes is now in widespread use by clinicians for the evaluation of patients with swallowing disorders. The prevalence and simplicity of this apparatus have encouraged its use by clinical specialists who are often not specifically trained in the safe use of x-ray equipment, and this may not be in the best interest of either the patient or the examiner. This has prompted an overview of the operating principles of videofluorescopy equipment. The factors governing image quality are discussed as well as potential hazards and protective measures for both patients and operator. A method of estimating the radiation dose to sensitive tissues from a typical swallowing study is included.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02412634

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 3 references

Research works printed but not linked: 3

  1. U.S. Dept. of Health and Human Services: 1987Annual Cancer Statistics Review. NIH Pub. No. 88-2789, 1988
  2. NAS/NRC:The Effects on Populations on Exposure to Low Levels of Ionizing Radiation: 1980, Committee on the Biological Effects of Ionizing Radiations of the National Academy of Sciences/National Research Council. Washington, DC: National Academy Press, 1980
  3. Suleiman OH:Development of a method to calculate organ doses for the upper gastrointestinal fluoroscopic examination. Doctoral thesis, The Johns Hopkins University, 1989

Cited by

See all 34

Metadata

Authors
Beck, T. J., & Gayler, B. W.
Affiliations
Johns Hopkins University (US)
Venue
Dysphagia
Published
1990-09
Volume
5
Issue
3
Pages
118-128
ISSN
  • 0179-051X (ISSN-L)
  • 1432-0460
OpenAlex
W2039041635
Cited by
34
References
3
Citations by year
2021: 2 · 2019: 1 · 2017: 1 · 2015: 1 · 2013: 2 · 2012: 1
FWCI
0.91
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Dysphagia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
Keywords
videofluoroscopy, image quality, radiation dose assessment, radiation protection, patient radiation exposure, operator radiation exposure
MeSH terms
Cineradiography, Deglutition, Fluoroscopy, Humans, Radiation Dosage, Radiation Protection, Radiographic Image Enhancement, Video Recording

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Image quality and radiation levels in videofluoroscopy for swallowing studies: A review. https://app.cochat.ai/papers/10.1007/bf02412634
The paper
Beck, T. J., & Gayler, B. W. (1990). Image quality and radiation levels in videofluoroscopy for swallowing studies: A review. Dysphagia. https://doi.org/10.1007/bf02412634

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.