Cited by 46Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesInfrared Thermography in Medicine

Photoplethysmography: Part 1 Comparison with laser Doppler flowmetry

Lindberg, L. G., Tamura, T., Öberg, P. Å.·1991·Medical & Biological Engineering & Computing

Abstract

Photoplethysmography (PPG) and laser Doppler flowmetry (LDF) were compared and evaluated. The comparison was accomplished considering differences in physical principles and geometrical and optical conditions. Changes in human skin perfusion were induced by cold and hot water provocation on limited areas of the finger and the forearm. The results showed that LDF and PPG, using red light at 630-660 nm and a commercial PPG probe, were in general equally sensitive in detecting a blood perfusion increase following a skin temperature elevation. However, we also found that PPG occasionally showed an inverse response to a skin temperature elevation, especially in finger skin. Furthermore, the study indicated that laser light is unsuitable as a light source in PPG using optical fibres of small diameter and with no fibre separation. It was also found that the physical dimensions of the probe (including the light source and photodetector) play an important role in determining the measuring volume and the quality of the signal.

Integrity signals

Registry

Crossref · 10.1007/bf02446294

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PPG amplitude showed a direct response to skin temperature elevation, especially in the finger skin.

    “Lindberg et al. found that PPG amplitude showed a direct response to skin temperature elevation, especially in the finger skin of 10 Caucasian young adults (aged 22–30) using three different arrangements of PPG probes with different source/detector separations [153].”

The citation lists haven’t been fetched yet

References 16 · Cited by 46

Authors
Lindberg, L. G., Tamura, T., & Öberg, P. Å.
Affiliations
  • Linköping University (SE)
  • Tokyo Medical and Dental University (JP)
Venue
Medical & Biological Engineering & Computing
Published
1991-01
Volume
29
Issue
1
Pages
40-47
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2329392758
Cited by
46
References
16
Citations by year
2025: 2 · 2024: 2 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 1
FWCI
1.28
Type
journal article
Language
en
Open access
closed
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
photoplethysmography, laser Doppler flowmetry, skin blood flow, skin temperature, finger skin, forearm skin, red light, optical fibers, probe geometry, signal quality
MeSH terms
Hot Temperature, Humans, Lasers, Photography, Plethysmography, Skin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review