Adaptive regulation of wall shear stress optimizing vascular tree function
The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“After seeding, microvessels were perfused with gravity-driven flow to provide approximately 4 dyn cm−2 shear stress, characteristic of post-capillary venules [45].”
From Role of iPSC-derived pericytes on barrier function of iPSC-derived brain microvascular endothelial cells in 2D and 3D (2019) · cites this paper as [45]
Citations
Cites
Thompson, D. W. (2019) · Stripped Bare · doi:10.1515/9780691183978-018 · Cited by 4,177
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
N., E., & Thompson, D. W. (1945) · The Journal of Philosophy · doi:10.2307/2019330 · Cited by 1,119
Adaptive regulation of wall shear stress to flow change in the canine carotid artery
Kamiya, A., & Togawa, T. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.1.h14 · Cited by 817
Self-citationTHE PHYSIOLOGICAL PRINCIPLE OF MINIMUM WORK APPLIED TO THE ANGLE OF BRANCHING OF ARTERIES
Murray, C. D. (1926) · Journal of General Physiology · doi:10.1085/jgp.9.6.835 · Cited by 750
Whitmore, R. L. (1968) · Medical Entomology and Zoology · Cited by 446
Rashevsky, N. P. (1935) · Nature · doi:10.1038/135528a0 · Cited by 315
Wikman-Coffelt, J., Parmley, W. W., & Mason, D. T. (1979) · Circulation Research · doi:10.1161/01.res.45.6.697 · Cited by 274
Mathematical biophysics: Physico-mathematical foundations of biology
Lyman, H. (1961) · Microchemical Journal · doi:10.1016/0026-265x(61)90055-8 · Cited by 221
Rodbard, S. (1975) · Cardiology · doi:10.1159/000169701 · Cited by 212
Research works printed but not linked: 3
- Green, H. D. 1950. “Circulatory System: Physical Principles.” InMedical Physics, Ed. O. Glasser, Vol. 2, pp. 228–251. Chicago, IL: Yearbook Publishers.
- Liebow, A. A. 1963. “Situations which Lead to Changes in Vascular Patterns.” InHandbook of Physiology, Circulation. Eds. W. F. Hamilton and P. Dow, Vol. 2, pp. 1251–1276. Washington, DC: American Physiology Society.
- Suwa, N. and T. Takahashi. 1971.Morphological and Morphometrical Analysis of Circulation in Hypertension and Ischemic Kidney. München: Urban & Schwarzenberg.
Cited by
Items 101–200 of 296
EphA4/Tie2 crosstalk regulates leptomeningeal collateral remodeling following ischemic stroke
Okyere, B., Mills, W. A., Wang, X., Chen, M., Jiang, C., Hazy, A., Qian, Y., Matson, J. B., & Theus, M. H. (2019) · Journal of Clinical Investigation · doi:10.1172/jci131493 · Cited by 50
“Collateral remodeling is initiated 45 when mechanoreceptors on endothelial cells (ECs) detect fluid shear stress after an occlusion (24-26).”
BackgroundMalek, A. M., Ahlquist, R. E., Gibbons, G. H., Dzau, V. J., & Izumo, S. (1995) · Methods in Cell Science · doi:10.1007/bf00996123 · Cited by 47
“The importance of the local fluid shear forces in determining vascular structure has been illustrated in numerous studies in vivo [ 11 , 12].”
BackgroundKassab, G. S., Gregersen, H. N., Nielsen, S. L., Lu, X., Tankó, L. B., & Falk, E. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00023 · Cited by 47
A pneumatic pressure-driven multi-throughput microfluidic circulation culture system
Satoh, T., Narazaki, G., Sugita, R., Kobayashi, H., Sugiura, S., & Kanamori, T. (2016) · Lab on a Chip · doi:10.1039/c6lc00361c · Cited by 45
Numerical Simulation of Enhanced External Counterpulsation
Ozawa, E. T., Bottom, K. E., Xiao, X. G., & Kamm, R. D. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1359448 · Cited by 49
Mechanosensory Mechanisms in Bone
Sharma, U., Mikos, A. G., & Cowin, S. C. (2007) · Elsevier eBooks · doi:10.1016/b978-012370615-7/50065-2 · Cited by 45
Mean Wall Shear Stress in the Femoral Arterial Bifurcation Is Low and Independent of Age at Rest
Kornet, L., Hoeks, A. P. G., Lambregts, J., & Reneman, R. S. (2000) · Journal of Vascular Research · doi:10.1159/000025722 · Cited by 44
“]and in such elastic arteries as the carotid artery [ , ,”
BackgroundInformation Transfer in Microvascular Networks
Secomb, T. W., & Pries, A. R. (2002) · Microcirculation · doi:10.1038/sj.mn.7800146 · Cited by 48
“This concept (40,64) is appealing, because such a scaling corresponds approximately to observations in the arterial tree (45), and furthermore, it satisfies the minimumcost principle known as Murray’s law (50).”
BackgroundFricker, M. D., Heaton, L. L. M., Jones, N. S., & Boddy, L. (2017) · ASM Press eBooks · doi:10.1128/9781555819583.ch15 · Cited by 57
Shamul, J. G., Wang, Z., Gong, H., Ou, W., White, A. M., Garcia, D. P. M., Gu, S., Clyne, A. M., Quiñones‐Hinojosa, A., & He, X. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01250-2 · Cited by 45
“The physiological range (10–20 dyne cm −2 ) 311,312 labelled in the scatterplots includes very few data points, which suggests that (1) more data are necessary for these higher shear stress experimental conditions to have more reliable fitting of the data and (2) more experiments should be…”
Fung, Y. C. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2696-1_3 · Cited by 51
Ishibazawa, A., Nagaoka, T., Yokota, H., Ono, S., & Yoshida, A. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.10.001 · Cited by 44
Ramachandra, A. B., Humphrey, J. D., & Marsden, A. L. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.0995 · Cited by 41
Shalman, E., Rosenfeld, M., Dgany, E., & Einav, S. (2002) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00033-6 · Cited by 40
“One is based on the well-known hypothesis that the mean WSS is constant not only in the coronary arteries but in the entire arterial system as well [17].”
BackgroundStrain or deformation rate dependent finite growth in soft tissues
Cowin, S. C. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00114-x · Cited by 38
“Adaptive remodeling (growth?) of the vasculature has been observed so as to maintain nearly constant endotheliaI fluid shear stress (rate of deformation to the cell) throughout the entire arterial side of the circulation (Kamiya et al., 1984).”
BackgroundAcademic User View: Organ-on-a-Chip Technology
Busek, M., Aizenshtadt, A., Amirola-Martinez, M., Delon, L., & Krauss, S. (2022) · Biosensors · doi:10.3390/bios12020126 · Cited by 37
“Mechanical stimulation is important for cell functionality and maturation [18]—most prominently by flow-induced shear stress [33].”
BackgroundInterspecific scaling of blood flow rates and arterial sizes in mammals
Seymour, R. S., Hu, Q., Snelling, E. P., & White, C. R. (2019) · Journal of Experimental Biology · doi:10.1242/jeb.199554 · Cited by 42
Blood Vessel Adaptation with Fluctuations in Capillary Flow Distribution
Hu, D., Cai, D., & Rangan, A. V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045444 · Cited by 36
“This conclusion is consistent with later experimental observations [7,28] – the wall shear stress varies within about one order of magnitude along the circulation system.”
Lee, J. Y., & Lee, S. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0454-1 · Cited by 42
“In general, Murray’s law has been proven to be quite accurate even though some investigators have found that the exponent may be closer to 2.7 or 3.2 ( Kamiya et al. 1984 ).”
BackgroundInfluentialWen, L., Yan, W., Zhu, L., Tang, C., & Wang, G. (2023) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-023-04801-z · Cited by 40
“The branching structure of the arterial tree is based on the adaptive response of the vessel diameter induced by wall shear stress [66].”
BackgroundLiu, C., Zhou, J., Kudlacek, S. T., Qi, T., Dunlap, T. C., & Cao, Y. (2023) · eLife · doi:10.7554/elife.83659 · Cited by 35
“…regimens and T cell proliferation profiles, the in-vivo model reasonably predicted B-cell depletion profiles in patients (Bargou et al., 2008; Klinger et al., 2012; Zhu et al., 2016; Zhu et al., 2018; Zugmaier et al., 2015) treated with blinatumomab in multiple clinical trials (Figure 6b-e,…”
MethodComputational Simulation of the Adaptive Capacity of Vein Grafts in Response to Increased Pressure
Ramachandra, A. B., Sankaran, S., Humphrey, J. D., & Marsden, A. L. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029021 · Cited by 33
“Homeostatic values rh 1⁄4 18 kPa; sw 1⁄4 0:6 Pa [49] P01⁄4 5 mmHg1⁄4 0.”
BackgroundStructure and hemodynamics of vascular networks in the chorioallantoic membrane of the chicken
Maibier, M., Reglin, B., Nitzsche, B., Xiang, W., Rong, W. W., Hoffmann, B., Djonov, V., Secomb, T. W., & Pries, A. R. (2016) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00786.2015 · Cited by 33
Price, R., Less, J. R., Gieson, E. J. V., & Skalak, T. C. (2002) · Microcirculation · doi:10.1038/sj.mn.7800127 · Cited by 33
“Several investigators have either experimentally or theoretically tested Murray’s hypothesis and, in general, have shown that the requirements of this hypothesis are met in the systemic arterial circulation (4), coronary arterial circulation (5), and cremaster muscle arteriolar microcirculation (9).”
BackgroundMethodResultInfluentialTissue engineering bioreactor systems for applying physical and electrical stimulations to cells
Jin, G., Yang, G. H., & Kim, G. (2014) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33268 · Cited by 35
Polarized Proteins in Endothelium and Their Contribution to Function
Wolpe, A. G., Ruddiman, C. A., Hall, P. J., & Isakson, B. E. (2021) · Journal of Vascular Research · doi:10.1159/000512618 · Cited by 36
Proteomic profiling of human bone marrow mesenchymal stem cells under shear stress
Yi, W., Sun, Y., Wei, X., Gu, C., Dong, X., Kang, X., Guo, S., & Dou, K. (2010) · Molecular and Cellular Biochemistry · doi:10.1007/s11010-010-0432-7 · Cited by 34
“The range of shear stress in arteries has been reported to be approximately 10‐25 dyn/cm 2 compared with approximately 1.5‐3 dyn/ cm 2 in veins [ 22 ].”
BackgroundInfluentialEffect of non-Newtonian viscosity on the fluid-dynamic characteristics in stenotic vessels
Huh, H. K., Ha, H., & Lee, S. J. (2015) · Experiments in Fluids · doi:10.1007/s00348-015-2037-0 · Cited by 35
Biomechanical Aspects of Growth and Tissue Engineering
Fung, Y. C. (1990) · Springer eBooks · doi:10.1007/978-1-4419-6856-2_13 · Cited by 37
A three-dimensional analysis of plasma skimming at microvascular bifurcations
Zong-yi, Y., Acrivos, A., & Weinbaum, S. (1991) · Microvascular Research · doi:10.1016/0026-2862(91)90072-j · Cited by 29
Mantilidewi, K. I., Murata, Y., Mori, M., Otsubo, C., Kotani, T., Kusakari, S., Ohnishi, H., & Matozaki, T. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.529503 · Cited by 29
“All SS experiments were performed at 37 °C in a CO2 incubator, with most being performed at 3 or 9 dyne/cm(2), both of which are within the physiological range of venous or arterial SS (20, 21).”
MethodFlexible Three-Dimensional Net for Intravascular Fishing of Circulating Tumor Cells
Cheng, S., Wang, M., Zhang, C., Chen, M., Wang, Y., Tian, S., Zhan, N., Dong, W., Xie, M., & Huang, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00203 · Cited by 28
Functional implications of microvascular heterogeneity for oxygen uptake and utilization
Roy, T. K., & Secomb, T. W. (2022) · Physiological Reports · doi:10.14814/phy2.15303 · Cited by 34
“In a vessel with a fixed flow rate, this response generates negative feedback that regulates shear stress to a set point (Kamiya et al., 1984; Rodbard, 1975).”
BackgroundContinuum Modeling of Biological Network Formation
Albi, G., Burger, M., Haškovec, J., Markowich, P. A., & Schlottbom, M. (2017) · Modeling and simulation in science, engineering & technology · doi:10.1007/978-3-319-49996-3_1 · Cited by 40
Scaling of cerebral blood perfusion in primates and marsupials
Seymour, R. S., Angove, S. E., Snelling, E. P., & Cassey, P. (2015) · Journal of Experimental Biology · doi:10.1242/jeb.124826 · Cited by 27
“Chronic and acute experimental changes in flow rates or blood pressure induce adaptive alteration in vessel geometry and normalize shear stress within narrow limits (Kamiya et al., 1984; Kamiya and Togawa, 1980; Langille, 1999; Smiesko and Johnson, 1993; Tronc et al., 1996).”
BackgroundEngineering the Human Blood–Brain Barrier at the Capillary Scale using a Double‐Templating Technique
Zhao, N., Guo, Z., Kulkarni, S., Norman, D., Zhang, S., Chung, T. D., Nerenberg, R. F., Linville, R. M., & Searson, P. C. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202110289 · Cited by 31
Piantino, M., Figarol, A., & Matsusaki, M. (2021) · Frontiers in Toxicology · doi:10.3389/ftox.2021.656254 · Cited by 27
In Vitro Flow Chamber Design for the Study of Endothelial Cell (Patho)Physiology
Fallon, M. E., Mathews, R., & Hinds, M. T. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051765 · Cited by 31
Hydrodynamic Effects of Compliance Mismatch in Stented Arteries
Selvarasu, N. K., Tafti, D. K., & Vlachos, P. P. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4003319 · Cited by 24
Yang, J., Chen, Y. M., Kurokawa, T., Gong, J. P., Onodera, S., & Yasuda, K. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32875 · Cited by 24
“3 kPa, which is close to the pressure exerted on capillaries (approximately 3 kPa), to avoid any damage to the cells [42, 43].”
BackgroundArtificial stenoses for computational hemodynamics
Doutel, E., Carneiro, J., Campos, J. B. L. M., & Miranda, J. M. (2018) · Applied Mathematical Modelling · doi:10.1016/j.apm.2018.01.029 · Cited by 26
The Design of Fluid Transport Systems: A Comparative Perspective
LaBarbera, M. (1995) · Springer eBooks · doi:10.1007/978-1-4614-7527-9_1 · Cited by 24
Some atherosclerosis may be a consequence of the normal adaptive vascular response to shear
Friedman, M. H. (1990) · Atherosclerosis · doi:10.1016/0021-9150(90)90040-p · Cited by 24
Blood Flow in Microvascular Networks
Pries, A. R., & Secomb, T. W. (2008) · Wiley eBooks · doi:10.1002/cphy.cp020401 · Cited by 37
Ohtani-Kaneko, R., Sato, K., Tsutiya, A., Nakagawa, Y., 橋爪和俊, & Tazawa, H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0229-5 · Cited by 27
A non-uniform three-dimensional perfusion model of rat tail heat transfer
Wu, Y., Jiji, L. M., Lemons, D. E., & Weinbaum, S. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/006 · Cited by 22
Doutel, E., Pinto, S. I. S., Campos, J. B. L. M., & Miranda, J. M. (2016) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2016.04.038 · Cited by 22
Liu, H., Gong, X., Jing, X., Ding, X., Yao, Y., Huang, Y., & Fan, Y. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2196 · Cited by 22
Zhu, L., Lemons, D. E., & Weinbaum, S. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02368295 · Cited by 22
“(18), the requirement that Q/(2a) 3 = constant is equivalent to requiring that the wall shear stress be unchanged.”
BackgroundErythrocytes, a New Contributor to Age‐Associated Loss of Blood–Brain Barrier Integrity
Amiri, P., DeCastro, J., Littig, J., Lu, H., Liu, C., Conboy, I. M., & Aran, K. (2021) · Advanced Science · doi:10.1002/advs.202101912 · Cited by 23
Computational study of pulsatile blood flow in prototype vessel geometries of coronary segments
Chaniotis, A. K., Kaiktsis, L., Katritsis, D. G., EFSTATHOPOULOS, E. P., Pantos, I., & Marmarelis, V. Z. (2010) · Physica Medica · doi:10.1016/j.ejmp.2009.03.004 · Cited by 21
“It is assumed that vascular WSS remains at an optimal range of time-averaged values of 15 dyn/cm(2) 50% [20].”
BackgroundShintani, Y., Iino, K., Yamamoto, Y., Kato, H., Takemura, H., & KIWATA, T. (2017) · Circulation Journal · doi:10.1253/circj.cj-17-0381 · Cited by 21
Amyloid Beta Influences Vascular Smooth Muscle Contractility and Mechanoadaptation
Hald, E. S., Timm, C. D., & Alford, P. W. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034560 · Cited by 22
Murray's Law in Elastin Haploinsufficient (Eln+/−) and Wild-Type (WT) Mice
Sather, B. A., Hageman, D. J., & Wagenseil, J. E. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4023093 · Cited by 20
“It has been argued that constant shear stress is the most likely regulatory factor in determining the diameter of branching vessels, as this is a local, cellular-level response, rather than a global optimization [16].”
BackgroundTension at the gate: sensing mechanical forces at the blood–brain barrier in health and disease
Hansen, C. E., Hollaus, D., Kamermans, A., & de Vries, H. E. (2024) · Journal of Neuroinflammation · doi:10.1186/s12974-024-03321-2 · Cited by 22
Sarkar, N., Sharma, S. D., Chakraborty, S. K., & Roy, S. (2024) · Computers & Fluids · doi:10.1016/j.compfluid.2024.106337 · Cited by 21
Local Hemodynamics of the Vascular Access for Hemodialysis
Malík, J., Tuka, V., & Tesař, V. (2009) · Kidney & Blood Pressure Research · doi:10.1159/000205522 · Cited by 20
“]].Unlike blood pressure, blood flow acts only on the inner surface of the arterial wall and thus directly affects only endothelial cells and not the medial and adventitial layers. Wall shear stress (WSS) is the mathematical description of the blood flow effect on the endothelium [ , , , ,”
BackgroundBogorad, M. I., & Searson, P. C. (2016) · Integrative Biology · doi:10.1039/c6ib00082g · Cited by 20
Epigenetic regulators of the revascularization response to chronic arterial occlusion
Heuslein, J. L., Gorick, C. M., & Price, R. J. (2019) · Cardiovascular Research · doi:10.1093/cvr/cvz001 · Cited by 21
Yuhn, C., Hoshina, K., Miyahara, K., & Oshima, M. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.05.043 · Cited by 19
Advancing Blood–Brain Barrier-on-a-Chip Models Through Numerical Simulations
Carvalho, V. M., Rodrigues, R. O., Shin, S. R., Lima, R. A., & Teixeira, S. (2024) · BioChip Journal · doi:10.1007/s13206-024-00168-w · Cited by 20
Optimality, cost minimization and the design of arterial networks
Hughes, A. D. (2015) · Artery Research · doi:10.1016/j.artres.2015.01.001 · Cited by 19
“Subsequent authors addressed the impact of turbulence 34 and viscosity across the network 34,35 .”
Reneman, R. S., Vink, H., & Hoeks, A. P. G. (2009) · Artery Research · doi:10.1016/j.artres.2009.02.005 · Cited by 18
“Only in the common carotid artery the value is close to the theoretically predicted value of 1.5 Pa.15 The lower mean WSS in these conduit arteries at rest can be explained by the high peripheral resistance in these vessels, reducing mean volume flow and inducing reflections.”
BackgroundInfluentialMECHANOSENSORY MECHANISMS IN BONE
Cowin, S. C., & Moss, M. L. (2000) · Elsevier eBooks · doi:10.1016/b978-012436630-5/50055-6 · Cited by 20
Is smooth muscle growth in primate arteries regulated by endothelial nitric oxide synthase?
Mattsson, E. J. R., Geary, R. L., Kraiss, L. W., Vergel, S., Liao, J. K., Corson, M. A., Au, Y. P., Hanson, S. R., & Clowes, A. W. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70138-7 · Cited by 18
Rundek, T., & Della‐Morte, D. (2015) · Brain Circulation · doi:10.4103/2394-8108.164993 · Cited by 20
“An inadequate EC response to SS plays a critical role in triggering angiogenesis, vascular remodeling,[12] and atherosclerosis.”
BackgroundCombination of flow and micropattern alignment affecting flow-resistant endothelial cell adhesion
Gong, X., Yao, J., He, H., Zhao, X., Liu, X., Zhao, F., Sun, Y., & Fan, Y. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.04.028 · Cited by 16
Effect of Wall Motion on Arterial Wall Shear Stress
FUKUI, T., Parker, K. H., Imai, Y., TSUBOTA, K.-I., Ishikawa, T., Wada, S., & Yamaguchi, T. (2007) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.2.58 · Cited by 16
On the Modeling of Growth and Adaptation
Cowin, S. C. (2006) · Springer eBooks · doi:10.1007/3-540-31184-x_3 · Cited by 16
The efficiency of the vascular-tissue system for oxygen transport in the skeletal muscles
Kamiya, A., Ando, J., Shibata, M., & Wakayama, H. (1990) · Microvascular Research · doi:10.1016/0026-2862(90)90068-3 · Cited by 16
Self-citationKawahara, D., & Matsuda, T. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32686 · Cited by 15
Single cell morphological metrics and cytoskeletal alignment regulate VCAM-1 protein expression
Fallon, M. E., & Hinds, M. T. (2021) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2021.03.129 · Cited by 15
Blood Flow in Arteries and Veins
Rubenstein, D. A., Yin, W., & Frame, M. D. S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381383-1.00005-9 · Cited by 15
Chen, Y. M., Kurokawa, T., Tominaga, T., Yasuda, K., Osada, Y., Gong, J. P., Yamamoto, K., & Ando, J. (2010) · Advanced Engineering Materials · doi:10.1002/adem.201080021 · Cited by 14
“exerted on the wall of blood vessel is 2 Pa [20] under the static pressure of 3 kPa for capillary [21].”
BackgroundMethodInfluentialGhriallais, R. N., McNamara, L. M., & Bruzzi, M. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0965 · Cited by 14
“Numerous experiments have shown active responses of the vasculature to altered haemodynamic forces, including structural remodelling of the vessel [10–17], altered cell morphologies [18–21], proliferation [14,15,22–24], expression of inflammatory genes ICAM-1 and VCAM-1 [25–28] and production of nitric oxide (NO) [17,…”
BackgroundResultInfluentialOptimisation of Biological Transport Networks
Lu, Y., & Hu, D. (2021) · East Asian Journal on Applied Mathematics · doi:10.4208/eajam.180521.130721 · Cited by 14
“This has been further validated by different experiments [28,42].”
ResultGharahi, H., Filonova, V., Mullagura, H. N., Nama, N., Baek, S., & Figueroa, C. A. (2023) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-023-01693-7 · Cited by 14
Mu, L., Liu, X., Liu, M., Long, L., Chi, Q., He, Y., Pan, Y., Ji, C., Gao, G., & Li, X. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.854109 · Cited by 13
“A previous study showed that the expression of inflammatory factors is consistent with variations in EC morphology, which can be explained by a stenosis degree of >50%, and WSS induced by stenosis exceeds the physiological range of the cell (Kamiya et al., 1984).”
BackgroundFunctional stability of endothelial cells on a novel hybrid scaffold for vascular tissue engineering
Pankajakshan, D., Krishnan, K., & Krishnan, L. K. (2010) · Biofabrication · doi:10.1088/1758-5082/2/4/041001 · Cited by 13
Cooperation of Nature and Physiologically Inspired Mechanisms in Visualisation
al‐Rifaie, M. M., Aber, A., & Bishop, J. M. (2012) · IGI Global eBooks · doi:10.4018/978-1-4666-0942-6.ch003 · Cited by 12
Zhang, X.-J., Li, C., Hao, W., Zhang, D., & Gao, B. (2018) · World Neurosurgery · doi:10.1016/j.wneu.2018.09.112 · Cited by 12
RetractedYamamoto, K., Maeno, R., Kawabe, K., Shimogonya, Y., & Ando, J. (2023) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00393.2023 · Cited by 12
Computational Analysis of Particle-Hemodynamics and Prediction of the Onset of Arterial Diseases
Kleinstreuer, C., Buchanan, J. R., Lei, M., & Truskey, G. A. (2000) · CRC Press eBooks · doi:10.1201/9781420049534.ch-01 · Cited by 12
Microtube-Embedded Microfluidic Devices for Potential Applications in Blood Brain Barrier Research
Sooriyaarachchi, D., Zhou, Y., Maharubin, S., & Tan, G. Z. (2020) · Procedia Manufacturing · doi:10.1016/j.promfg.2020.05.050 · Cited by 13
Optimum capillary number for oxygen delivery to tissue in man
Kamiya, A., Takeda, S., & Shibata, M. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02460125 · Cited by 11
Self-citationOptimal postnodal lymphatic network structure that maximizes active propulsion of lymph
Venugopal, A. M., Quick, C. M., Laine, G. A., & Stewart, R. H. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00360.2008 · Cited by 13
Ye, S. S., Ju, M., & Kim, S. (2016) · Microvascular Research · doi:10.1016/j.mvr.2016.03.003 · Cited by 11
McDougall, S. R., Chaplain, M. A. J., Stéphanou, A., & Anderson, A. R. A. (2010) · Mathematical Modelling of Natural Phenomena · doi:10.1051/mmnp/20105108 · Cited by 12
“(1984) [24].”
ResultKeshi, E., Tang, P., Weinhart, M., Everwien, H., Moosburner, S., Seiffert, N., Lommel, M., Kertzscher, U., Globke, B., Reutzel‐Selke, A., et al. (2021) · Journal of Biological Engineering · doi:10.1186/s13036-021-00277-2 · Cited by 10
Mechanical Homeostasis of Cardiovascular Tissue
Kassab, G. S. (2008) · Springer eBooks · doi:10.1007/978-3-540-75409-1_15 · Cited by 10
“Kamiya et al. (1984) reported that the WSS varies by about a factor of 2 (approximately 10 – 20 dyne/cm2) in the arterial tree (aorta to pre-capillary arterioles).”
BackgroundCombining microchip and cell technology for creation of novel biodevices
Sato, K., Tanaka, Y., Renberg, B., & Kitamori, T. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2450-9 · Cited by 10
Bevan, J. A. (1991) · Humana Press eBooks · doi:10.1007/978-1-4612-0403-9_11 · Cited by 10
A biochemomechanical model of collagen turnover in arterial adaptations to hemodynamic loading
Tilahun, H. G., Mullagura, H. N., Humphrey, J. D., & Baek, S. (2023) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-023-01750-1 · Cited by 11
High hemodynamic stresses induce aneurysms at internal carotid artery bends
Guo, H., Yang, S., Wang, J., Li, H., Gao, B., & Li, C. (2023) · Medicine · doi:10.1097/md.0000000000034587 · Cited by 9
Szukiewicz, D., Trojanowski, S., Wróbel, E., Wojdasiewicz, P., & Szewczyk, G. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26199565 · Cited by 9
NAKADATE, H., Hirose, Y., Sekizuka, E., & Minamitani, H. (2008) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.3.25 · Cited by 8
Domain dynamics of phase-separated lipid membranes under shear flow
Hamada, T., Mizuno, S., & Kitahata, H. (2022) · Soft Matter · doi:10.1039/d2sm00825d · Cited by 8
Sugii, Y. (2010) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.5.625 · Cited by 8
Nguyen, P. H., Knezek, S. F., Mohiuddin, M. W., Tüzün, E., & Quick, C. M. (2014) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00537.2014 · Cited by 8
“These rules were based on consensus for the most commonly assumed stimulus for each mechanical property (8, 15, 17, 38, 41, 43, 57, 58).”
Hirayama, Y., Nakanishi, R., Tategaki, A., Maeshige, N., Kondo, H., Ishihara, A., Roy, R. R., & Fujino, H. (2017) · Microcirculation · doi:10.1111/micc.12356 · Cited by 8
Metadata
- Authors
- Kamiya, A., Bukhari, R., & Togawa, T.
- Affiliations
- Tokyo Medical and Dental University (JP)
- Venue
- Bulletin of Mathematical Biology
- Published
- 1984-01
- Volume
- 46
- Issue
- 1
- Pages
- 127-137
- ISSN
- 0092-8240 (ISSN-L)
- 1522-9602
- OpenAlex
- W2059661208
- Cited by
- 298
- References
- 30
- Citations by year
- 2026: 2 · 2025: 11 · 2024: 9 · 2023: 9 · 2022: 5 · 2021: 14 · 2020: 9 · 2019: 10 · 2018: 5 · 2017: 15 · 2016: 10 · 2015: 15 · 2014: 11 · 2013: 13 · 2012: 16
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Bulletin of Mathematical Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Keywords
- wall shear stress, vascular tree, adaptive regulation, hemodynamics, blood flow, vascular function
- MeSH terms
- Adaptation, Physiological, Animals, Arteries, Biomechanical Phenomena, Blood Viscosity, Dogs, Models, Cardiovascular, Stress, Mechanical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.