The DOI matches its Crossref record.
Vascular Caliber
Abstract
Many aspects of vascular caliber can be accounted for on the basis of interactions between the frictional drag generated by the stream, and the sensitivity of the endothelial cells to this force. When the drag force on endothelial cells is at its critical set-point, these lining cells are at rest with respect to factors that affect caliber. An increase in flow rate increases the drag and appears to induce the endothelium to generate a signal that triggers relaxation of the subjacent medial smooth muscle. The resulting functional dilatation of the vessel reduces the stream velocity and returns the drag to its set-point. If the drag stimulus is persistent or recurrent, vasodilatation is soon followed by anatomical reorganization of the vessel around its enlarged lumen. This sequence can account for gradual, generalized and regional vascular growth, and for the opening of collateral vessels. This sequence may also play a role in the enlargement of veins, lymphatics, airways and other vessels. Turbulence greatly increases drag per unit volume of flow. Aneurysms and and post-stenotic dilatations are considered to result from an increased drag. Jets increase drag to an even greater extent and may account for saccular aneurysms and for ‘jet lesions’. Conversely, reduced flow diminishes drag and thereby triggers constriction of the vascular smooth muscle. Persistent reduction of drag permits proliferation of the subendothelial connective tissue, which reduces vascular caliber until the drag on the lining cells is returned to its set-point. Progressive localized narrowings (stenoses) may also be attributed to a reduced drag. Thus high velocity flow around an irregularity such as a plaque may separate the streamlines from the wall at the downstream end of the narrowing. In this region of separation the cells respond to the reduced local flow and drag by subendothelial proliferation and ingrowth, producing further narrowing. These mechanisms may be operative in
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Langille, B. L., & O'Donnell, F. (1986) · Science · doi:10.1126/science.3941904 · Cited by 1,113
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli
Green, D. J., Hopman, M. T. E., Padilla, J., Laughlin, M. H., & Thijssen, D. H. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00014.2016 · Cited by 821
Endothelial fluid shear stress sensing in vascular health and disease
Baeyens, N., Bandyopadhyay, C., Coon, B. G., Yun, S., & Schwartz, M. A. (2016) · Journal of Clinical Investigation · doi:10.1172/jci83083 · Cited by 575
Metadata
- Authors
- Rodbard, S.
- Venue
- Cardiology
- Publisher
- S. Karger AG
- Published
- 1975
- Volume
- 60
- Issue
- 1
- Pages
- 4-49
- ISSN
- 0008-6312 (ISSN-L)
- 1421-9751
- OpenAlex
- W4230830236
- Cited by
- 212
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vascular Caliber. https://app.cochat.ai/papers/10.1159/000169701
- The paper
- Rodbard, S. (1975). Vascular Caliber. Cardiology. https://doi.org/10.1159/000169701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.