CoChat

Laboratory diagnosis of iron-deficiency anemia: An overview

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Abstract

Background and methods To determine the diagnostic values of laboratory tests used in the diagnosis of iron-deficiency anemia, the authors conducted a systematic overview of the relevant literature. Computerized searches of the MEDLINE database yielded 1,179 potentially relevant citations. Fifty-five studies included the results of laboratory tests and histologic examination of the bone marrow for at least 50% of an identifiable patient group. In these 55 studies, quality was assessed and descriptive information concerning the study populations, the tests conducted, and the results was extracted, all in duplicate. Results Serum ferritin radioimmunoassay was by far the most powerful test, with an area under the receiver operating characteristic curve of 0.95. Test properties differed for populations of patients with inflammatory, liver, or neoplastic disease and patients without these conditions. Likelihood ratio lines, which allow precise interpretation of results across the entire range of ferritin concentration values, were constructed for the individual populations. Conclusion Serum ferritin radioimmunoassay is an extremely powerful test for the diagnosis of iron-deficiency anemia and, appropriately interpreted, can be applied to the complete range of patients.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02598003

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 81 references

Research works printed but not linked: 1

  1. Witte DL, Dick F, Goeken J, et al. C-reactive protein aids interpretation of serum ferritin. Clin Chem. 1985;31:1011.

Cited by

See all 564

Metadata

Authors
Guyatt, G. H., Oxman, A. D., Ali, M., Willan, A., McIlroy, W., & Patterson, C.
Affiliations
McMaster University (CA)
Venue
Journal of General Internal Medicine
Published
1992-03
Volume
7
Issue
2
Pages
145-153
ISSN
  • 0884-8734 (ISSN-L)
  • 1525-1497
OpenAlex
W1984935423
Cited by
564
References
81
Citations by year
2026: 15 · 2025: 32 · 2024: 20 · 2023: 16 · 2022: 25 · 2021: 27 · 2020: 18 · 2019: 19 · 2018: 20 · 2017: 23 · 2016: 27 · 2015: 28 · 2014: 22 · 2013: 16 · 2012: 27
FWCI
2.16
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Journal of General Internal Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
  • Health Sciences › Medicine › Hematology › Hematological disorders and diagnostics
  • Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
Keywords
iron deficiency anemia, serum ferritin, radioimmunoassay, diagnostic accuracy, likelihood ratios, receiver operating characteristic, bone marrow histology, inflammatory diseases, liver disease, cancer
MeSH terms
Anemia, Hypochromic, Ferritins, Humans, ROC Curve, Likelihood Functions, Clinical Laboratory Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.